Oil Lubricated Compressors
Troubleshooting Chart
Symptom | Possible Cause(s) | Corrective Action | ||
|
|
|
|
|
Compressor will not run | 1. | Switch in OFF position | 1. | Make sure compressor is plugged in and switch is ON. |
| 2. | No electrical power at wall outlet | 2. | Check circuit breaker or fuse at electrical panel. |
| 3. | Compressor has reached automatic | 3. | Release air from tank until compressor restarts |
|
| shutoff pressure |
| automatically. |
| 4. | Motor overheated | 4. | Allow compressor to cool for approximately 30 |
HL5403, HL5404
Para ordenar repuestos, sírvase llamar al distribuidor más cercano a su domicilio
Sírvase darnos la siguiente información: |
|
|
| Puede escribirnos a: |
|
|
|
|
| Attn: Parts Dept. |
|
| |
|
|
| 100 Production Drive |
|
| |
|
| Harrison, OH 45030 USA |
|
| ||
|
|
|
|
|
|
|
No. de | HL5403 |
|
| No. de | HL5403 |
|
Ref. Descripción | HL5404 | Ctd. |
| Ref. Descripción | HL5404 | Ctd. |
|
|
|
|
|
|
|
|
|
|
|
|
| minutes so thermal overload switch will reset. Make |
| ||
|
|
|
|
|
| sure compressor is run in a clean, |
| ||
|
| 5. | Pressure switch bad | 5. | Replace pressure switch. |
| |||
|
|
|
|
|
| ||||
| Motor hums but cannot | 1. Defective check valve | 1. | Repair or replace. |
| ||||
| run or runs slowly | 2. Defective unloader valve (on pressure | 2. | Repair or replace. |
| ||||
|
|
| switch) |
|
|
|
|
|
|
|
| 3. | Low voltage | 3. | Check voltage at wall outlet with voltmeter. |
| |||
|
| 4. | Loose electrical connections | 4. | Check all electrical connections. |
| |||
|
| 5. | Wrong gauge wire or length of | 5. | Check extension cord chart for proper extension cord |
| |||
|
|
| extension cord |
|
| usage. |
| ||
|
| 6. | Defective motor capacitor | 6. | Replace capacitor. |
| |||
|
| 7. | Shorted or open motor winding | 7. | Replace motor assembly. |
| |||
|
|
|
|
|
|
|
| Do not disassemble check |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| valve with air in tank; |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| bleed tank |
| ||||
|
|
|
|
|
| ||||
| Flow blows/circuit | 1. Incorrect fuse size, circuit overloaded | 1. | Check for proper fuse. Use time delay fuse. |
| ||||
| breaker trips repeatedly |
|
|
|
| Disconnect other electrical appliances from circuit or |
| ||
|
|
|
|
|
| operate compressor on its own branch circuit. |
| ||
|
| 2. | Wrong gauge wire or length of | 2. | Check extension cord chart for proper extension cord |
| |||
|
|
| extension cord |
|
| usage. |
| ||
|
| 3. | Defective check valve | 3. | Repair or replace. |
| |||
|
| 4. | Defective unloader valve (on pressure | 4. | Repair or replace. |
| |||
|
|
| switch) |
|
|
|
|
|
|
|
| 5. | Defective motor capacitor | 5. | Replace capacitor. |
| |||
|
| 6. | Motor shorted or seized | 6. | Replace motor assembly. |
| |||
|
|
|
|
|
|
|
| Do not disassemble check |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| valve with air in tank; |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| bleed tank |
| ||||
|
|
|
|
|
| ||||
| Thermal overload | 1. Low voltage | 1. | Check voltage at wall outlet with voltmeter. |
| ||||
| protector cuts out | 2. Wrong gauge wire or length of | 2. | Check extension cord chart for proper extension cord |
| ||||
| repeatedly |
| extension cord |
|
| usage. |
| ||
|
| 3. | Clogged intake filter | 3. | Clean or replace filter. |
| |||
|
| 4. | Lack of proper ventilation/room | 4. | Move compressor to |
| |||
|
|
| temperature too high |
|
|
|
|
|
|
|
| 5. | Defective check valve | 5. | Repair or replace. |
| |||
|
| 6. | Defective unloader valve (on pressure | 6. | Repair or replace. |
| |||
|
|
| switch) |
|
|
|
|
|
|
|
| 7. | Compressor valves failed | 7. | Replace valve assembly. |
| |||
|
|
|
|
|
|
|
| Do not disassemble check |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| valve with air in tank; |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| bleed tank |
| ||||
|
|
|
|
|
|
|
|
| |
| Knocks, rattles, and/or | 1. Loose mounting bolts | 1. Tighten bolts. |
| |||||
| excessive vibration | 2. Tank not level | 2. Use sturdy wedge/object to bring tank to level position. |
| |||||
|
| 3. | Cylinder or piston is worn/scored | 3. Replace or repair as necessary. |
| ||||
|
|
|
|
|
|
|
|
|
|
1 | Filtro de aire (incluye los elementos) HL030100AV | 1 | |
2 | Codo | HL030200AV ▲▲ 1 | |
3 | Arandela, M6 | ■ | 8 |
4 | Perno del cabezal, M6 x 50 | ■ | 4 |
5 | Cabeça do cilindro | ■ | 1 |
6 | Junta del cabezal | ● | 1 |
7 | Placa de la válvula | ◆ | 2 |
8 | Junta metálica | ◆ | 1 |
9 | Válvula | ◆ | 2 |
10 | Empaque para la placa de la válvula ● | 1 | |
11 | Cilindro | ▼ | 1 |
12 | Perno del cilindro, M8 x 25 | ▼ | 2 |
13 | Empaque del cilindro | ● | 1 |
14 | Pasador | ★ | 1 |
15 | Anillo de compresión | ★ | 2 |
16 | Anillo de aceite | ★ | 1 |
17 | Retenes del pasador de pistón | ★ | 2 |
18 | Pistón | ★ | 1 |
19 | Varilla de conexión | HL030300AV | 1 |
20 | Perno, M6 x 20 | 5 | |
21 | Arandela, M6 | 1 | |
22 | Excéntrica | 1 | |
23 | Condensador | ❋ | 1 |
24 | Arandela, M8 | ▼ ❋ | 4 |
25 | Tuerca, M8 | ❋ ▲▲ | 2 |
26 | Cubierta de la caja del cigüeñal | 1 | |
27 | Anillo en O | ❏ | 1 |
28 | Ventanilla | ❏ | 1 |
29 | Anillo en O | ❍ | 1 |
30 | Tapón del orificio de drenaje, |
|
|
| M5 x 10 | ❍ | 1 |
31 | Anillo en O | ◆◆ | 1 |
32 | Respiradero | ◆◆ | 1 |
33 | Junta de la tapa de la caja |
|
|
| del cigüeñal | ● | 1 |
34 | Caja del cigüeñal | 1 | |
35 | Arandela, M5 | 4 |
|
36 | Tornillo de la cubierta, M5 x 16 | 4 | |
37 | Sello del sistema de lubricación | 1 | |
38 | Cojinete | 1 | |
39 | Rotor | 1 | |
40 | Cojinete | 1 | |
41 | Estator | 1 | |
42 | Marco en campana del extremo |
|
|
| posterior del motor | 1 | |
43 | Sobrecarga térmica | 1 | |
44 | Ventilador | 1 | |
45 | Circlip | 1 | |
46 | Arandela, M5 | 4 | |
47 | Arandela de seguridad, M5 | 4 | |
48 | Perno de motor, M5 x 120 | 4 | |
49 | Válvula de encendido fácil | HL036200AV | 1 |
50 | Tapa | 1 | |
51 | Filtro de aire y Elemento del filtro | HL030100AV | 1 |
52 | Perno | 4 | |
53 | Perno | 4 | |
54 | Acople (Modelo HL5403) | 1 | |
| Acople (Modelo HL5404) | 2 | |
55 | Ménsula del panel de control | 1 | |
56 | Arandela | 2 |
57 | Tuerca | 1 | ||
58 | Manómetro (Lado izquierdo) | HL036300AV | 1 | |
59 | Manómetro (Lado derecho) | HL036100AV | 1 | |
| 60 | Múltiple (Modelo HL5403) | HL035700AV | 1 |
|
| Múltiple (Modelo HL5404) | HL036500AV |
|
61 | Mango | 1 | ||
62 | Tubo | ✖ | 1 | |
63 | Codo | ✖ HL035800AV 1 | ||
64 | Tubo de descarga | ▲ | 1 | |
| 65 | Tuerca | ▲ | 2 |
66 | Manga | ▲ | 2 | |
67 | Válvula de seguridad | HL030900AV | 1 | |
68 | Cordón eléctrico | 1 | ||
69 | Cordón del motor | 1 | ||
| 70 | Base | 1 | |
71 | Presostato | HL031000AV | 1 | |
72 | Válvula de chequeo | HL030500AV | 1 | |
73 | Tapón | 1 | ||
74 | Conexión de tubo | ✖ HL035900AV 1 | ||
| 75 | Manga | ◗ | 2 |
76 | Tuerca | ◗ | 2 | |
77 | Tubo de escape | ◗ | 1 | |
78 | Perno | 2 | ||
79 | Arandela | ✣ | 6 | |
| 80 | Válvula de drenaje | HL030700AV | 1 |
81 | Pata de caucho | ✣ | 4 | |
82 | Perno | ✣ | 4 | |
83 | Ensamble del tanque | 1 | ||
84 | Manga | ▲ | 1 | |
85 | Tuerca | ▲ | 1 | |
| JUEGOS DE PIEZAS PARA MANTENIMIENTO |
| ||
| ■ | Juego de culata (incluye 3, 4 y 5) | HL031200AV |
|
| ● | Juego de empaques |
|
|
|
| (incluye 6, 10, 13, y 33) | HL031300AV |
|
◆Juego del plato de la válvula
| (incluye 7, 8, y 9) | HL031400AV |
▼ | Juego del cilindro |
|
| (incluye 11, 12, and 24) | HL031500AV |
★ | Juego de pistones |
|
| (incluye 14, 15, 16, 17, y 18) | HL031600AV |
❋Juego del condensador (incluye
| 23, 24, y 25) | HL036400AV |
▲▲ | Juego de cubierta de la caja del cigüeñal | |
| (incluye 3, 20, y 26) | HL031800AV |
❏Juego del visor de vidrio
(incluye 27 y 28) | HL031900AV |
❍Juego del tapón de drenaje
| (incluye 29 y 30) | HL032000AV |
◆◆ | Juego de respiración (incluye |
|
| 31 y 32) | HL032100AV |
▼▼ | Juego del ventilador (incluye |
|
| 51 y 52) | HL032200AV |
◗Kit de tubo de escape
| (incluye 75, 76, y 77) | HL032300AV |
✣ | Juego de pata (incluye 79, 81 y 82) | HL032400AV |
▲ | Juego de tubo de descarga |
|
| (incluye 64, 65 , y 66) | HL032500AV |
✖Juego de tubo del colector
(incluye 62, 63, y 74) | HL036000AV |
6 | 27 Sp |
|