APC 412 kVA Reminder Checklist, Purchase of System, Site Preparation, Electrical Preparation

Page 17

CHAPTER 3: SITE PREPARATION

Reminder Checklist

Purchase of System

Have you ...

1.determined your load power and runtime requirements?

2.purchased redundant power and battery module if desired?

3.evaluated and selected a service plan?

Refer to http://www.apc.com/products/symmetra_rm for answers to these and other questions.

Site Preparation

Have you ...

1.determined where to install your UPS and ensured that enough rack space is available?

2.verified that the floor can support the total weight of a fully loaded system?

3.ensured that the site meets minimum environmental requirements, including HVAC?

Answers to these and other installation questions are found in the following sections.

Electrical Preparation

Have you ...

1.verified that the required input voltage is available?

2.scheduled an electrician for connecting the branch circuit (mains) or to hardwire the system?

3.determined all output-wiring configurations to be installed?

4.provided a copy of this document to the electrician?

Answers to these and other wiring questions are found in the following sections.

13

Image 17
Contents APC Symmetra RM KVA UPS Installation Manual Page Safety and General Information Installation Conventions Used in this Manual General Equipment SafetyHandling Safety Battery Safety Deenergizing SafetyElectrical Safety Japan and 200 V Countries North America and 208 V CountriesEurope and 230 V Countries Countries Regulatory Agency ApprovalsDeclaration of Conformity Europe and 230 V Countries Life Support Policy Limited WarrantyCopyright and Trademark Information APC Contact Numbers and SupportSafety and General Information About Your UPS Replacement Modules Model Number DescriptionEurope JapanDistribution PowerOptions Extended RunFront View Component Identification Product OverviewRear View Component Identification UPS- Rear View SYPD3 installedMIM RIM System Block DiagramBasics Purchase of System Reminder ChecklistSite Preparation Electrical PreparationWeights Length Width Height Measurements Inches cm Short-Term Battery Module Storage RequirementsShipping & Receiving Lbs kgPhysical Requirements Installation RequirementsEnvironmental Requirements Thermal DissipationElectrical Requirements Remote Emergency Power Off RepoContents Installing the UPSMoving the UPS to the Installation Site UnpackingInstallation Installing in a Four Post Rack Installation Installation Japan 200 Wiring the UPSPower Cord Ratings Switch Setting North America Installation Installation Completing the Installation Installation Connecting Load Equipment to the UPS Final Installation Checklist Replacing Power Modules Post Installation ProceduresReplacing Battery Modules Replacing Intelligence Modules Technical Reference Operational SpecificationsInput Specifications Compliance Specifications Output SpecificationsPhysical Specifications APC Symmetra RM 4-12 kVA UPS Page Messages Table of Contents Menu Description PowerViewNavigation Navigation Name Sound Function Keys FunctionsTurning on the UPS Powering Up the Load Equipment Powering Down the Load Equipment Bypass Operation Shown connected to Symmetra RM 2-6 kVA Language SettingTypical Programming Cable Getting Started Getting Started Accessories Menu Command ReferenceControl Menu Menu Item FunctionDisplay Function Options Display MenuLogging Menu Diagnostics MenuHelp Menu Status Menu Menu Item Function Options Setup MenuUPS ID PowerView Message Meaning Corrective Action TroubleshootingMessages Meaning Corrective Action Messages PowerView Message Meaning Corrective Action Messages Service Maintenance

412 kVA, SYBT3 specifications

The APC SYBT3 412 kVA is a high-performance uninterruptible power supply (UPS) system designed to provide reliable power solutions for critical applications in various industries. Ideal for data centers, telecom infrastructures, and other mission-critical operations, the APC SYBT3 is engineered to deliver a robust power backup to prevent downtime.

One of the main features of the APC SYBT3 is its impressive capacity of 412 kVA. This high power output ensures that it can support large loads while maintaining stable operations even during power fluctuations. The system is designed to handle essential equipment, guaranteeing that your operations continue without interruption.

The APC SYBT3 utilizes advanced technologies to optimize performance and energy efficiency. This includes an intelligent battery management system that prolongs battery life while ensuring reliable energy delivery. The UPS is equipped with a modern inverter that efficiently converts DC battery power to AC power, enabling seamless transitions during power outages.

Another key characteristic of the APC SYBT3 is its modular design, which allows for easy integration into existing systems. This modularity supports scalability, enabling users to expand their power capacity as needed without significant infrastructure changes. This feature is particularly beneficial for organizations that anticipate growth or fluctuations in power requirements.

The APC SYBT3 also boasts superior communications features, including an advanced monitoring interface. This feature allows for real-time tracking of power parameters, battery health, and operational status, ensuring users can address potential issues before they escalate. Remote monitoring capabilities enable IT personnel to manage the UPS from anywhere, enhancing operational efficiency.

In addition to its robust power performance, the APC SYBT3 offers a compact footprint, making it suitable for environments where space is limited. This design consideration ensures that large power needs can be met without sacrificing valuable real estate.

Overall, the APC SYBT3 412 kVA UPS represents a blend of advanced engineering, efficient power management, and user-friendly features. Its ability to provide seamless power continuity makes it an indispensable asset for organizations seeking to safeguard their critical operations against power interruptions.