System Configuration

The System Information menu contains two configuration items: System Startup Default and Audible Alarm. Both are user configuration items and are selected by pressing ENTER.

System Startup Default You can set the initial power-up configuration when AC shorepower is provided to the Prosine inverter/charger so that the inverter and charger are either both On, both Off, or one is On and the other is Off. This is a User configuration item set by pressing ENTER, scrolling to the desired value by pressing an arrow key, pressing ENTER to select the value, and pressing ESCAPE to exit the menu. The  indicates the current selection.

SELECT FROM: SYSTEM INFO

ENTER

SYSTEM INFO: DEFAULT INV/CHG

ENTER

DEFAULT INV/CHG

ÂINV ON/CHG ON

DEFAULT INV/CHG INV OFF/CHG OFF

DEFAULT INV/CHG INV OFF/CHG ON

DEFAULT INV/CHG INV ON/CHG OFF

ENTER

Audible Alarm The System Info menu also allows you to turn the audible alarm Off or On. The audible alarm sounds any time there is an inverter/charger fault, or when the DC high- or low-voltage range is exceeded. If equipped with a battery temperature sensor, the audible alarm will also sound when battery temperature is less than -15°C (5°F) or more than 50°C (122°F). The audible alarm is always accompanied by flashing LEDs and an error code display. The alarm is ENABLED at the factory.

SELECT FROM: SYSTEM INFO

ENTER

SELECT FROM: ALARM AUDIBLE

AUDIBLE ALARM: ENABLED

ENTER

AUDIBLE ALARM:

 

Â

DISABLED

ENTER

 

 

36

Prosine 2.5/3.0 Installation & Operation Guide

Image 54
Contents PS2.5 PS3.0 Page Installation and Operation Guide ProsineTMDate and Revision Important Safety Instructions Precautions When Working with Batteries Materials List System / Installation Information Inverter/Charger Components Prosine 2.5/3.0 Installation & Operation Guide Warranty Disclaimer ProductReturn Material Authorization Policy Return Procedure Contents Configuration Operation Appendix B Inverter Applications Features Battery Charger FeaturesInverter Features Features Inverter Features Controls and Indicators DIP Switch PanelAccessory Jacks AC Bypass Selector DC Terminals & CoversAC Terminals & Covers Standard LED Control Panel Standard LED Control Panel DisplayBattery Status Indicator Faults Indicators & Reset ButtonInverter Status Indicators and On/Off Button Power Indicator Charger Status Indicator and On/Off ButtonMounting and Installing the LED Control Panel ACS Control Panel Liquid Crystal Display Control ButtonsMenu Navigation Procedure ACS Menu TreeAC Information Menu Battery Information Menu Inverter Information MenuCharger Information Menu Charger StatusSystem Information Menu Version Information Menu Faults Display & Reset Button Inverter Status Indicators and On/Off ButtonPower Indicator Charger Status Indicator and On/Off ButtonMounting and Installing the ACS Control Panel Battery Temperature Sensor Battery Temperature SensorBattery Temperature Sensor Configuration DIP Switch SettingsNot used Battery TypeBattery Temperature Load SenseSwitch 5, 6, 7 Switch 2 Not Used RatingAmps CurrentDrawSwitch Breaker MaxAC 12V 24VACS Configuration User Configuration ItemsInstaller Configuration Items ACS Configuration Considerations AC Shorepower Configuration Battery Configuration Battery TypeBattery Size Battery Temperature Battery Info Type Flooded Inverter Configuration Load Sense TURN- on POWER1401 WCharger Configuration High and Low Voltage Alarms and CutoffsEqualize is NOW Disabled Equalize is NOW Enabled System Configuration Inverter/Charger Installation Safety InstructionsInstallation Overview Installation Overview Inverter/Charger Installation Designing the Installation Gfci Models Where to Install the Prosine Inverter/Charger Tools and Materials RequiredAmbient temperature deg. C Mounting the Prosine Inverter/Charger AC Cabling Recommended Wire Size vs Breaker RatingAC and DC Wiring Separation AC Disconnect and Overload ProtectionWire Size Fuse Size DC CablingDC Over-Current Protection DC Cabling Connections Battery Cable RoutingDC Disconnect 10 ft 15 ft 20 ft 30 ftDC Cabling Procedure Recommended DC Cable Sizes For Proper OperationConnecting the Battery Temperature Sensor DC GroundingMounting Options Mounting to the Negative Battery Terminal BTS Attached to Negative Battery TerminalMounting to the Side of the Battery Case BTS Attached to Battery CaseTypical System Diagrams Residential Backup SystemRecreational Vehicle System Residential Solar and Wind System Operation Prosine Inverter Load Sense Mode Operating Limits for Inverter OperationProsine Operating Voltage Limits Operating Limits for Inverter Operation Bulk Charge Multistage ChargingCharging Profile Absorption ChargeFloat Charge Equalization ChargeOperation in Charger Mode Operation in Equalization ModeEqualization Procedure Adjustable Charger Mode Settings Battery Charging Times Operating Limits for Charger OperationBattery Charging and Equalization Guide Model Flooded Comments GelAGM Operating Limits for Charger Operation Batteries TerminologyTypes Starting Batteries Deep-Cycle BatteriesEnvironment TemperatureSealed Gel Cell LocationBattery Bank Sizing Estimating Battery RequirementsBattery Bank Sizing Example & Worksheet Battery Sizing ExampleBattery Sizing Worksheet Preparation Monthly Battery MaintenanceCleaning Batteries AttireProcedure EquipmentSupplies Parallel Connection Cabling & Hook-up ConfigurationsCables 50 AhSeries Connection 100 AhSeries Parallel Connection 24VCabling & Hook-up Configurations Appendix a Specifications Prosine 2.5 12-volt Prosine 3.0 12-voltVolt in parenthesis Charger Output Voltages Prosine 2.5 12-volt Prosine 3.0 12-volt Volt in parenthesisProsine 2.5/3.0 Chassis Dimensions Prosine 2.5/3.0 Chassis Dimensions with Brackets Prosine 2.5 Efficiency Curve Prosine Over-Current Shutdown ResponseProsine 2.5 Efficiency 120Vac, 12Vdc model Prosine 2.5/3.0 Installation & Operation Guide Resistive Loads Problem Loads in Load SenseAppendix B Inverter Applications Inductive LoadsOther Problem Loads Appendix C Troubleshooting What to do if a problem occursError Code Displays and What They Mean Control PanelAdvanced Control System ACS Error Code Table Error Description of Fault Possible Cause Solution CodeError Code Table Appendix C Troubleshooting Error Description of Fault Possible Cause Solution Code Error Description of Fault Possible Cause Solution Code Error Code Table Index Index Gases, battery venting, 50 gel-cell,30 Index Index 100 Page 445-0096-01-01

PS3.0, PS2.5 specifications

Xantrex Technology has made significant strides in the power electronics sector with the introduction of their PS2.5 and PS3.0 inverter models. These inverters are designed primarily for solar energy applications, offering reliable and efficient power conversion for residential and commercial solar installations. The PS series stands out in the market due to its advanced features, innovative technologies, and user-friendly characteristics.

One of the main features of the Xantrex PS2.5 and PS3.0 inverters is their high efficiency rating, typically above 97%. This means that a minimal amount of energy is lost during conversion, allowing users to maximize their solar energy utilization. Additionally, these inverters come with a wide input voltage range, making them versatile and capable of handling various solar panel configurations.

Both models are equipped with advanced MPPT (Maximum Power Point Tracking) technology. This feature optimizes the energy output from solar panels by constantly adjusting the operating point to ensure maximum power is extracted, even in variable weather conditions or partial shading. This capability significantly enhances the overall energy harvest from solar systems.

Another notable characteristic is their compact and lightweight design, which facilitates easy installation and integration into existing systems. The inverters are also designed with robust thermal management solutions, ensuring they operate effectively even in high-temperature environments. This durability extends their lifespan and increases reliability, critical factors for any solar installation.

Xantrex has also prioritized user experience with the PS2.5 and PS3.0 models by providing a built-in monitoring system. Users can access real-time data on energy production, performance metrics, and system status through a user-friendly interface. This connectivity allows for quick troubleshooting and maintenance, thus enhancing the overall efficiency of solar energy systems.

Safety is paramount in the design of these inverters. They meet stringent international safety standards and come equipped with comprehensive protection features, including over-voltage, under-voltage, and short-circuit protection. This ensures the inverter operates safely, protecting both the user and the connected solar array.

In summary, Xantrex Technology's PS2.5 and PS3.0 inverters are engineered with cutting-edge features and technologies that cater to the evolving needs of solar energy users. Their efficiency, adaptability, and focus on safety make them an excellent choice for those looking to invest in renewable energy solutions. As the demand for sustainable energy continues to rise, Xantrex is poised to play a significant role in the market with these innovative inverter solutions.