Xantrex Technology 20, 10, 15, 30, 25 owner manual Batteries, Battery Interconnection

Page 13

BATTERIES

Beware of so-calledmaintenance-free wet cell batteries. These batteries have calcium alloyed with the lead liquid. They are sealed and water cannot be added. Do not confuse them with true gel cell or AGM batteries—they will not hold up well to deep discharging and repeated cycling.

Gel Cell Batteries

Gel cell batteries are lead-acid batteries similar in many ways to the common wet cell battery, but differences in the chemistry and construction provide some unique features.

No Maintenance

Low Self-Discharge Rate

Low Internal Resistance

Even though gel cells are sealed batteries, the battery compartment should still be ventilated.

Advanced AGM (Absorbed Glass Mat) Batteries

This battery is lead acid but maintenance free. They hold the liquid electrolyte in a sponge-like material. The performance is similar to gel cell batteries. The charge parameters are similar to wet cell batteries.

Battery Selection

The most important feature to consider in making your battery selection is to select true deep cycle batteries rated in amp hours (Ah) and sized to match your power requirements.

BATTERY INTERCONNECTION

In most cases, you will be using a bank of two or more batteries with your inverter/charger. You may connect batteries together in two configurations—series and parallel— depending on their voltage.

Series Configuration

Connecting two batteries in series will double the voltage of the battery bank. For instance, two 6 volt batteries connected in series will produce 12 volts. The amp-hour capacity of the battery bank will be the same as each individual battery. Example, two 6 volt 220 amp-hour batteries in series will produce one 12 volt 220 amp-hour battery bank.

+ +

Series

Series Increase Voltage

+

+

+

6V

6V

12V INVERTER

_

_

_

 

 

EACH BATTERY

 

TOTAL BATTERY

CAPACITY:

 

BANK CAPACITY:

220

 

220

AMP HOURS

 

AMP HOURS

@ 6 VDC

 

@ 12 VDC

13

Image 13
Contents Page Disclaimer Safety SummaryTable of Contents Freedom Amps DC Freedom WattsIntroduction Circuit Breaker Protection Power SharingInverter Idle Circuit Electronic Protection Temperature Sensitive Charging TSCCharge Mode Invert ModeOperation LOW Battery & OVER-TEMP/OVERLOAD LOW Battery Red LEDBattery Type Selection OVER-TEMP/OVERLOAD Red LEDOptional Remotes TSC Temperature Sensitive ChargingRemote Control Panel Optional Remote Control PanelsAdvanced Remote Control Panels Link Instruments LinkWet Cell Batteries Battery TypesBatteries Battery InterconnectionBattery Bank Ratings and Sizing Parallel ConfigurationParallel AMP-HOUR Consumption Formulas Battery Charging Battery ChargingFreedom Battery Chargers Battery charger stages are Acceptance to Float Transition Points Battery Charging Battery Charger Voltage Settings Accessories Needed for Installation Installation PrecautionsConfirm that your shipping carton contains Typical Tools NeededKey Installation Points Installation+ Positive Negative Neutral Bonding GroundingGround/green AC WiringWhite to White Black to BlackGround Fault Circult Interrupters InstallationDC Wiring Battery Cable Connections For Freedom 10 Battery Cable FusingInstallation Options Installation OptionsInverter/charger configurations Dual In/Dual Out Configuration Installation Option 1 for Freedom Marine 10, 15, 20, 25, Freedom Marine Installation OptionFreedom Marine Model 10, 15, 20, 25 Installation Option 2 for Freedom Marine 10, 15, 20, 25,Installation Option 3 for Freedom Marine 25 Freedom Marine Installation Option Installation Option 4 for Freedom Marine 25 Dual Input/ Dual Output Test the transfer function Installation ChecksTest the battery charger function Troubleshooting LED Status Voltage TroubleshootingGlossary LED Light Emitting Diode Indicator light Specifications What does this warranty cover? WarrantyProduct Return Procedure Page Xantrex Technology Inc
Related manuals