BATTERY CHARGING

Battery Charging

Completely charging wet cell deep-cycle batteries requires the battery voltage to be raised beyond what is known as the gassing point. This is the voltage at which the battery begins to bubble and gas is given off. If charging stops short of this point, sulfate is left on the plates and deterioration of the battery begins. The gassing point will vary with battery temperature.

At 77 °F, the gassing point of a 12 volt bat- tery is about 14.0 volts.

AGM and Gel cell batteries must not be charged to their gassing point. In fact, high voltage charging that gasses these batteries is harmful to them. They typically require a lower bulk charge voltage. Gel cell batteries require a higher float voltage than wet cell bat- teries. Consult the battery manufacturer for specifications.

Freedom Battery Chargers

Freedom battery chargers are designed to overcome the limitations of conventional chargers by utilizing three distinct charge stages, each designed for optimal charging of wet, gel cell and AGM deep-cycle batteries. Battery type selection is made on the front panel of the inverter/charger or through the Remote Control Panel or a Link Instrument. For more information on battery type selection, see page 9 or refer to the Remote Control Panel manual.

16

Image 16
Contents Page Safety Summary DisclaimerTable of Contents Freedom Watts Freedom Amps DCIntroduction Circuit Breaker Protection Power SharingInverter Idle Circuit Temperature Sensitive Charging TSC Electronic ProtectionCharge Mode Invert ModeOperation LOW Battery Red LED LOW Battery & OVER-TEMP/OVERLOADBattery Type Selection OVER-TEMP/OVERLOAD Red LEDTSC Temperature Sensitive Charging Optional RemotesOptional Remote Control Panels Remote Control PanelAdvanced Remote Control Panels Link Instruments LinkBattery Types Wet Cell BatteriesBattery Interconnection BatteriesBattery Bank Ratings and Sizing Parallel ConfigurationParallel AMP-HOUR Consumption Formulas Battery Charging Battery ChargingFreedom Battery Chargers Battery charger stages are Acceptance to Float Transition Points Battery Charging Battery Charger Voltage Settings Installation Precautions Accessories Needed for InstallationConfirm that your shipping carton contains Typical Tools NeededInstallation Key Installation Points+ Positive Negative Grounding Neutral BondingAC Wiring Ground/greenWhite to White Black to BlackGround Fault Circult Interrupters InstallationDC Wiring Battery Cable Connections Battery Cable Fusing For Freedom 10Installation Options Installation OptionsInverter/charger configurations Dual In/Dual Out Configuration Freedom Marine Installation Option Installation Option 1 for Freedom Marine 10, 15, 20, 25,Installation Option 2 for Freedom Marine 10, 15, 20, 25, Freedom Marine Model 10, 15, 20, 25Installation Option 3 for Freedom Marine 25 Freedom Marine Installation Option Installation Option 4 for Freedom Marine 25 Dual Input/ Dual Output Installation Checks Test the transfer functionTest the battery charger function Troubleshooting LED Status Troubleshooting VoltageGlossary LED Light Emitting Diode Indicator light Specifications Warranty What does this warranty cover?Product Return Procedure Page Xantrex Technology Inc
Related manuals
Manual 68 pages 34.63 Kb