Xantrex Technology 30, 10, 15, 20, 25 Temperature Sensitive Charging TSC, Electronic Protection

Page 7

THINGS YOU SHOULD KNOW

The Power Sharing set point of each unit has a factory default setting. This can be changed when using the Freedom or Link remote control panel. Refer to the Freedom Remote Control Panel or Link manual for information on Power Sharing setting and adjustment.

Temperature Sensitive Charging (TSC)

When the supplied battery temperature

sensor is connected to the unit and the batteries, the charge voltage is controlled based on battery temperature. The charger adjusts the charge voltage to the best level insuring safe charging for selected battery type. Charge voltage regulation optimizes the battery life cycle.

Electronic Protection

Fast-acting electronic circuits protect the inverter from overloads and short circuits. Other protection includes a low and high battery voltage cutoff and automatic shutdown if an over temperature condition occurs. When the fault condition is corrected, the unit will automatically reset. For example: remove overload, charge batteries or allow to cool.

TSC Sensor

Battery

7

Image 7
Contents Page Disclaimer Safety SummaryTable of Contents Freedom Amps DC Freedom WattsIntroduction Circuit Breaker Protection Power SharingInverter Idle Circuit Electronic Protection Temperature Sensitive Charging TSCCharge Mode Invert ModeOperation OVER-TEMP/OVERLOAD Red LED LOW Battery Red LEDLOW Battery & OVER-TEMP/OVERLOAD Battery Type SelectionOptional Remotes TSC Temperature Sensitive ChargingLink Optional Remote Control PanelsRemote Control Panel Advanced Remote Control Panels Link InstrumentsWet Cell Batteries Battery TypesBatteries Battery InterconnectionBattery Bank Ratings and Sizing Parallel ConfigurationParallel AMP-HOUR Consumption Formulas Battery Charging Battery ChargingFreedom Battery Chargers Battery charger stages are Acceptance to Float Transition Points Battery Charging Battery Charger Voltage Settings Typical Tools Needed Installation PrecautionsAccessories Needed for Installation Confirm that your shipping carton containsKey Installation Points Installation+ Positive Negative Neutral Bonding GroundingBlack to Black AC WiringGround/green White to WhiteGround Fault Circult Interrupters InstallationDC Wiring Battery Cable Connections For Freedom 10 Battery Cable FusingInstallation Options Installation OptionsInverter/charger configurations Dual In/Dual Out Configuration Installation Option 1 for Freedom Marine 10, 15, 20, 25, Freedom Marine Installation OptionFreedom Marine Model 10, 15, 20, 25 Installation Option 2 for Freedom Marine 10, 15, 20, 25,Installation Option 3 for Freedom Marine 25 Freedom Marine Installation Option Installation Option 4 for Freedom Marine 25 Dual Input/ Dual Output Test the transfer function Installation ChecksTest the battery charger function Troubleshooting LED Status Voltage TroubleshootingGlossary LED Light Emitting Diode Indicator light Specifications What does this warranty cover? WarrantyProduct Return Procedure Page Xantrex Technology Inc