INSTALLATION

Bolt the positive (+) battery cable with 3/8'' ring terminal to the positive (red +) terminal assembly on the side of the inverter. Tighten the battery terminal bolts to a torque value between 160 inch-pounds and 180 inch- pounds. Secure the cover on the positive terminal (found in the accessory package) before continuing the installation.

The negative (-) cable should be connected directly to the negative post of the house or auxiliary battery bank or the ground side of a current shunt. Tighten securely.

The positive (+) battery cable must be fused and connected to the positive post of the house or auxiliary battery bank, or through a selector switch to one or more battery banks.

A spark may be generated when the final battery connection is made. This is normal; do not be alarmed. However, do not make the final connection in the presence of flammable fumes.

If multiple batteries are used, the interconnecting jumper cables should be the same AWG as those connected to the inverter/charger.

If utilizing the echo-charge feature to charge starting or auxiliary battery banks, use 12 AWG to make the connection between the echo-charge output and the positive (+) terminal post of the auxiliary battery. Each output should be fused within 72 inches of the battery with a 20 ampere fuse.

12 AWG

 

echo-charge

1

Auxiliary

echo-charge

2

or Start battery

 

 

Freedom Marine Inverter/Charger 10, 15, 20 1 echo-charge output

25, 30 2 echo-charge outputs

Battery Cable Connections

POSITIVE (+)

(Battery Cable Cover on)

POSITIVE (+)

(Battery Cable Cover off)

NEGATIVE (-)

NEGATIVE (-)

(Battery Cable Cover on)

(Battery Cable Cover off)

27

Image 27
Contents Page Disclaimer Safety SummaryTable of Contents Freedom Amps DC Freedom WattsIntroduction Power Sharing Circuit Breaker ProtectionInverter Idle Circuit Electronic Protection Temperature Sensitive Charging TSCInvert Mode Charge ModeOperation OVER-TEMP/OVERLOAD Red LED LOW Battery Red LEDLOW Battery & OVER-TEMP/OVERLOAD Battery Type SelectionOptional Remotes TSC Temperature Sensitive ChargingLink Optional Remote Control PanelsRemote Control Panel Advanced Remote Control Panels Link InstrumentsWet Cell Batteries Battery TypesBatteries Battery InterconnectionParallel Configuration Battery Bank Ratings and SizingParallel AMP-HOUR Consumption Formulas Battery Charging Battery ChargingFreedom Battery Chargers Battery charger stages are Acceptance to Float Transition Points Battery Charging Battery Charger Voltage Settings Typical Tools Needed Installation PrecautionsAccessories Needed for Installation Confirm that your shipping carton containsKey Installation Points Installation+ Positive Negative Neutral Bonding GroundingBlack to Black AC WiringGround/green White to WhiteInstallation Ground Fault Circult InterruptersDC Wiring Battery Cable Connections For Freedom 10 Battery Cable FusingInstallation Options Installation OptionsInverter/charger configurations Dual In/Dual Out Configuration Installation Option 1 for Freedom Marine 10, 15, 20, 25, Freedom Marine Installation OptionFreedom Marine Model 10, 15, 20, 25 Installation Option 2 for Freedom Marine 10, 15, 20, 25,Installation Option 3 for Freedom Marine 25 Freedom Marine Installation Option Installation Option 4 for Freedom Marine 25 Dual Input/ Dual Output Test the transfer function Installation ChecksTest the battery charger function Troubleshooting LED Status Voltage TroubleshootingGlossary LED Light Emitting Diode Indicator light Specifications What does this warranty cover? WarrantyProduct Return Procedure Page Xantrex Technology Inc