Studer Innotec HPC7048, HPC2512, HPC4024, HPC5048 user manual Battery, Cabling

Page 9

STUDER INNOTEC

HP-COMPACT

3.4 Connection Plan

Remote

L

B

 

H

control

 

RCT-01

D

 

A

 

C

 

 

 

 

 

E

 

 

 

F

 

 

L

N

 

 

 

 

 

 

 

Battery

 

 

 

 

 

 

AC in

temperature sensor CT35

remote power sharing RPS-01

 

 

 

 

G

Auxiliary

contact

 

N

K

 

L

N

AC out

M

J

A

Battery +/-

Connection terminal (M8) for battery cable (HPC 4024/5048/

 

 

7048 with fuse)

BReserved

C

Remote contr.

Connection terminal for Remote Control RCC-01

D

Transfer delay

Slide switch for Transfer Delay

E

Equalize

Slide switch for equalization of the Battery

F

Temp.

Connection terminal for Temperature sensor CT-35 and/or

 

 

Remote Power Sharing RPS-01

G

Aux. Contact

Connection terminal for Auxiliary Contact

H

AC Input

Connection terminal for AC-input

J

ID Plate

Identification plate with Technical data and Serial number

K

AC Output

Connection terminal for AC-output

LReserved

M

Hole

Pass through hole for RCC-01, CT-35 and RPS-01

N

Protection

Thermal circuit breaker 30A (50A for HPC7048) for the

 

 

Transfer system

3.5Cabling

Connecting the HP-COMPACT is a very important step of the installation. You must take care that all connection work is carried out in a clean and correct way and that under no circumstance a cable is connected to a wrong terminal.

Connecting of the HP-COMPACT must be carried out in the following order. In case of dismantling this order must be reversed.

User manual

HP-COMPACT V3.0 E

9

Image 9
Contents User and installer Manual Summary Warranty Disclaimer Quality and WarrantyGeneral Information Operating instructionsSpecial precautions PrecautionsIntroduction Remote control Battery chargerRemote control for Power Sharing Battery connectingInstallation place Mounting and installingConnection in serie Connection in parallel and in serieFixing General instructions on connectingConnections Protection cover of the terminals connectionsCabling BatteryConnection to battery Pre-installation settingsConnection to Temperature Sensor Temp Connection to Remote controlConnection to the 230Vac-consumer appliances AC Output Connection to the 230Vac Input AC InputControl Charger InverterDisplay and control parameters Push buttons Turning KnobsInverter Charge detection system „Standby Battery ConditionOverload Overheating Over TempEqualization charging Cycle of chargeCharging current Input current repartition Power sharingSet the transfer voltage threshold Transfer systemFast UPS- Mode for the Transfer Switch Delayed mode of the Transfer SystemMultifunctional Contact Temperature sensor Remote ControlProgramming Battery voltageAuxiliary contact Table of voltage and timing thresholdPrinciple Set the voltage and timing thresholdExample start of a genset with the HP-COMPACT Diagram of the different modes Power cut of the second priority loadsManual operating of Auxiliary Contact Disabling some of the HP-COMPACT functionsEC Compliance Installation MaintenanceHPC2512 HPC4024 HPC5048 HPC7048 Technical Data