To Attach The Guide Post Guard:
1.Remove the Knob Bolt (25B) which locks the Guide Post (24B) in position. (See Figure X.)
2.Align the two holes in the Upper Guide Cover (83B) with the Knob Bolt hole (25B) and the hole located at the bottom/front of the Upper Frame Arm (1B).
3.Attach the Upper Guide Cover (83B) to the Upper Frame Arm (1B), using the Hex Bolt (86B), the Washer (85B), and the Lock Washer (87B).
4.Replace the Knob Bolt (25B). Adjust the Guide Post (24B) to the desired height, and securely tighten the Knob Bolt.
FIGURE W
To Adjust The Angle Of The Table:
FIGURE X
1.The Bandsaw is equipped with a Table (36B) capable of being adjusted up to 150 to the left and up to 450 to the right. (See Figures Y* and Z*.)
2.To adjust the Table (36B) to ensure the Table is 900 to the Saw Blade, loosen the two Knobs (15B) which are located on the underneath of the Table.
3.Tilt the Table (36B) to the left or right until the Needle points to “0” on the Scale (40B). Then, securely tighten the two Knobs (15B).
(*Figures Y and Z see page 16.)
| REV 04/02 |
SKU 32208/32206 For technical questions, please call | PAGE 15 |