RACK MOUNTING
The Endura workstation mounts into an
The rack must meet the following requirements:
•Rack standard:
•Rack column depth: 20 to 30 inches (50.8 to 76.2 cm).
•Column mounting hole provisions:
•Door systems (optional): Front doors must have at least 2 inches (5.1 cm) between the Endura workstation front bezel and the inside of the door. Rear doors may be used only on rack columns that are more than 26 inches (66.0 cm) deep.
WARNING: Slots and openings in the cabinet provide ventilation to prevent the unit from overheating. Do not block these openings. Never place the unit near or over a radiator or heat register. When placing the unit in a
NOTE: Figure 3 identifies each piece of hardware for this procedure.
To install the Endura workstation in a rack:
1.If chassis mounting brackets are not attached: Attach one mounting bracket to each side of the Endura workstation. Use four
2.Remove the four rubber feet from the underside of the unit if they are attached. Save the rubber feet and screws for possible future use.
3.Attach one
(3) SCREWS,
Figure 6. Assembling a Support Rail
4. Repeat step 3 for the other rail set.
11 |