Bryant 566E, 576C, 569F, 566D Combination Ratings, 569D072/524A-C090 with HIGH-CAPACITY 4-ROW Coil

Page 17

PERFORMANCE DATA (cont)

COMBINATION RATINGS (cont)

UNIT 569D072 (cont)

569D072/524A-C090 WITH HIGH-CAPACITY 4-ROW COIL*

Temp (F)

 

 

 

 

 

 

 

Evaporator Air — Cfm

 

 

 

 

 

 

Air Entering

 

 

2400

 

 

 

 

 

3000

 

 

 

 

3750

 

Condenser

 

 

 

 

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

62

 

67

 

72

57

 

62

 

67

 

72

57

62

 

67

72

 

 

 

 

 

 

 

 

 

 

 

TC

71.9

72.9

 

78.3

 

84.8

77.7

 

77.7

 

81.3

 

87.6

81.6

81.6

 

83.4

89.4

80

 

SHC

71.9

69.5

 

57.7

 

45.1

77.7

 

77.7

 

67.0

 

50.9

81.6

81.6

 

75.2

56.4

 

 

kW

4.55

4.57

 

4.67

 

4.79

4.66

 

4.66

 

4.73

 

4.85

4.73

4.73

 

4.77

4.89

 

 

TC

70.9

71.7

 

76.9

 

83.3

76.5

 

76.5

 

79.8

 

86.1

80.3

80.3

 

81.9

87.8

85

 

SHC

70.9

68.8

 

57.2

 

44.6

76.5

 

76.5

 

66.4

 

50.3

80.3

80.3

 

74.6

55.9

 

 

kW

4.83

4.84

 

4.94

 

5.07

4.93

 

4.93

 

5.00

 

5.12

5.01

5.01

 

5.04

5.16

 

 

TC

68.8

69.3

 

74.2

 

80.4

74.1

 

74.1

 

76.9

 

82.9

77.7

77.8

 

79.0

84.5

95

 

SHC

68.8

67.5

 

56.1

 

43.5

74.1

 

74.1

 

65.2

 

49.3

77.7

77.8

 

73.3

54.8

 

 

kW

5.37

5.38

 

5.48

 

5.61

5.48

 

5.48

 

5.54

 

5.66

5.55

5.56

 

5.58

5.70

 

 

TC

67.7

68.0

 

72.8

 

78.8

72.8

 

72.9

 

75.4

 

81.3

76.4

76.4

 

77.4

82.8

100

 

SHC

67.7

66.8

 

55.5

 

43.0

72.8

 

72.9

 

64.6

 

48.8

76.4

76.4

 

72.5

54.3

 

 

kW

5.68

5.69

 

5.79

 

5.92

5.79

 

5.79

 

5.85

 

5.97

5.87

5.87

 

5.89

6.01

 

 

TC

66.5

66.8

 

71.3

 

77.3

71.6

 

71.6

 

73.9

 

79.6

75.0

75.0

 

75.9

81.1

105

 

SHC

66.5

66.0

 

54.9

 

42.5

71.6

 

71.6

 

64.0

 

48.2

75.0

75.0

 

71.8

53.7

 

 

kW

5.99

6.00

 

6.09

 

6.23

6.10

 

6.10

 

6.15

 

6.28

6.18

6.18

 

6.20

6.32

 

 

TC

64.3

64.3

 

68.4

 

74.2

69.0

 

69.1

 

70.8

 

76.2

72.3

72.3

 

72.7

77.7

115

 

SHC

64.3

64.3

 

53.8

 

41.4

69.0

 

69.1

 

62.8

 

47.1

72.3

72.3

 

70.3

52.6

 

 

kW

6.61

6.61

 

6.71

 

6.85

6.73

 

6.73

 

6.77

 

6.90

6.81

6.8

 

6.81

6.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

569D072/524A-B090 WITH STANDARD 3-ROW COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

Evaporator Air — Cfm

 

 

 

 

 

 

Air Entering

 

 

2400

 

 

 

 

 

3000

 

 

 

 

3750

 

Condenser

 

 

 

 

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

62

 

67

 

72

57

 

62

 

67

 

72

57

62

 

67

72

 

 

 

 

 

 

 

 

 

 

 

TC

68.4

69.5

 

74.8

 

81.0

73.6

 

73.6

 

77.6

 

83.8

77.3

77.3

 

79.5

85.5

80

 

SHC

68.4

65.8

 

54.8

 

42.9

73.6

 

73.6

 

63.1

 

48.1

77.3

77.3

 

70.4

52.9

 

 

kW

4.49

4.51

 

4.61

 

4.72

4.58

 

4.58

 

4.65

 

4.77

4.65

4.65

 

4.69

4.81

 

 

TC

67.4

68.4

 

73.6

 

79.7

72.6

 

72.6

 

76.3

 

82.4

76.1

76.1

 

78.2

84.0

85

 

SHC

67.4

65.2

 

54.3

 

42.4

72.6

 

72.6

 

62.6

 

47.6

76.1

76.1

 

69.8

52.4

 

 

kW

4.76

4.78

 

4.88

 

5.00

4.86

 

4.86

 

4.93

 

5.05

4.92

4.92

 

4.96

5.08

 

 

TC

65.5

66.2

 

71.1

 

77.1

70.4

 

70.5

 

73.7

 

79.5

73.8

73.8

 

75.5

81.1

95

 

SHC

65.5

64.0

 

53.3

 

41.5

70.4

 

70.5

 

61.5

 

46.6

73.8

73.8

 

68.7

51.4

 

 

kW

5.31

5.32

 

5.42

 

5.54

5.40

 

5.40

 

5.47

 

5.59

5.47

5.47

 

5.51

5.62

 

 

TC

64.5

65.1

 

69.7

 

75.6

69.3

 

69.3

 

72.3

 

78.0

72.6

72.6

 

74.0

79.5

100

 

SHC

64.5

63.3

 

52.8

 

41.0

69.3

 

69.3

 

60.9

 

46.1

72.6

72.6

 

68.0

50.9

 

 

kW

5.62

5.63

 

5.72

 

5.85

5.71

 

5.72

 

5.78

 

5.90

5.78

5.78

 

5.82

5.93

 

 

TC

63.4

63.9

 

68.4

 

74.1

68.1

 

68.1

 

70.9

 

76.5

71.4

71.4

 

72.6

77.9

105

 

SHC

63.4

62.5

 

52.2

 

40.5

68.1

 

68.1

 

60.4

 

45.6

71.4

71.4

 

67.3

50.4

 

 

kW

5.93

5.94

 

6.03

 

6.16

6.03

 

6.03

 

6.08

 

6.21

6.10

6.10

 

6.12

6.24

 

 

TC

61.4

61.6

 

65.8

 

71.2

65.9

 

65.8

 

68.0

 

73.4

68.9

68.9

 

69.7

74.8

115

 

SHC

61.4

61.1

 

51.2

 

39.4

65.9

 

65.8

 

59.2

 

44.6

68.9

68.9

 

66.0

49.4

 

 

kW

6.55

6.55

 

6.64

 

6.78

6.65

 

6.65

 

6.70

 

6.83

6.72

6.73

 

6.74

6.86

LEGEND

Edb — Entering Dry Bulb

Ewb — Entering Wet Bulb

kW — Compressor Motor Power Input

SHC — Sensible Heat Capacity (1000 Btuh) Gross

TC — Total Capacity (1000 Btuh) Gross

*This combination is ENERGY STAR® compliant.

569D072-120, 576C120, 569F120

17

Image 17
Contents 524A AIR-HANDLING Units FEATURES/BENEFITSTable of Contents Sound LEVELS, dB 569D/576C/566D,E Estimated Sound Power Levels Lw 524A072-300ARI* Capacity Ratings 566D, 566E, 569D, 569F, 576C FACTORY-INSTALLED Options Options and AccessoriesFIELD-INSTALLED Accessories Options and AccessoriesCommercial Programmable Non-Programmable Thermostat Options and Accessories524A-B, C FACTORY-INSTALLED Options 524A with Economizer 524A with Condensate Trap 524A with Discharge Plenum, Return Grille, and Subbase524A with Hot Water or Steam Coil IV Determine FAN RPM and BHP Brake Horsepower Selection ProcedureII Select Condensing Unit AIR-HANDLER Combination III Determine Sizes of Liquid and Suction LinesOperating Sequences Controls569D090, 208/230-3-360 and 460-3-60 Units Typical Wiring Schematics576C120, 208/230-3-60 and 460-3-60 Units Typical Wiring SchematicsModel Number Nomenclature Unit Physical Data569D072-120, 576C120, 569F120 Units 569D072-120, 576C120 Dimensions569D072 DimensionsCondensing Unit Ratings Performance DataCombination Ratings Performance Data569D072/524A-C072 with HIGH-CAPACITY 4-ROW Coil SHC2400 3000 3750 Condenser Combination Ratings569D072/524A-C090 with HIGH-CAPACITY 4-ROW Coil 569D090/524A-C072 with HIGH-CAPACITY 4-ROW Coil Unit 569D090Temp F 569D090/524A-B072 with Standard 3-ROW Coil569D090/524A-B090 with Standard 3-ROW Coil 569D090/524A-C090 with HIGH-CAPACITY 4-ROW Coil2205 3000 3750 Condenser 569D120/524A-C120 with HIGH-CAPACITY 4-ROW Coil Unit 569D1203000 4000 5000 Condenser 569D120/524A-B120 with Standard 3-ROW Coil569D120/524A-B150 with Standard 3-ROW Coil 569D120/524A-C150 with HIGH-CAPACITY 4-ROW Coil3750 5000 6250 Condenser 576C120/524A-B120 with Standard 3-ROW Coil Unit 576C120576C120/524A-C120 with HIGH-CAPACITY 4-ROW Coil 576C120/524A-B150 with Standard 3-ROW Coil 576C120/524A-C150 with HIGH-CAPACITY 4-ROW Coil569F120/524A-B120 with Standard 3-ROW Coil Unit 569F120569F120/524A-C120 with HIGH-CAPACITY 4-ROW Coil 569F120/524A-B150 with Standard 3-ROW Coil 569F120/524A-C150 with HIGH-CAPACITY 4-ROW CoilElectrical Data Application Data 569D072-120, 576C090-120, 569F120 Operating Limits Minimum OUTDOOR-AIR Operating TemperatureMaximum Refrigerant Charge Refrigerant Piping SizesRooftop Installation 569D072-120, 576C120 Typical Piping and WiringCommercial AIR-COOLED Condensing Units Guide Specifications 569D072-120, 576C120Part 1 General Part 2 ProductsGuide Specifications 569D072-120, 576C120 Guide Specifications 569F120 Guide Specifications 569F120 566D E X 150 566D150-240 Units 566E150-240 Units Physical DataDimensions Dimensions Aluminum Coil Unit 566D150-240, 566E150-240Air Temperature Entering Condenser F 100 105 115 566D150/524A-C150 with High Capacity 4-ROW Coil Unit 566D150Edb 566D150/524A-B150 with Standard 3-ROW Coil566D150/524A-B180 with Standard 3-ROW Coil 566D150/524A-C180 with High Capacity 4-ROW Coil4500 6000 7500 Condenser 566D180/524A-B180 with Standard 3-ROW Coil Unit 566D180566D180/524A-C180 with HIGH-CAPACITY 4-ROW Coil 566D180/524A-B240 with Standard 3-ROW Coil 566D180/524A-C240 with HIGH-CAPACITY 4-ROW Coil000 10,000 Condenser 566D240/524A-C300 with HIGH-CAPACITY 4-ROW Coil Unit 566D240500 10,000 12,500 Condenser 566D240/524A-B300 with Standard 3-ROW Coil566E150/524A-B120 with Standard 3-ROW Coil Unit 566E150566E150/524A-C120 with HIGH-CAPACITY 4-ROW Coil 566E150/524A-B150 with Standard 3-ROW Coil 566E150/524A-C150 with HIGH-CAPACITY 4-ROW Coil566E150/524A-B180 with Standard 3-ROW Coil 566E150/524A-C180 with HIGH-CAPACITY 4-ROW Coil566E180/524A-B150 with Standard 3-ROW Coil Unit 566E180566E180/524A-C150 with HIGH-CAPACITY 4-ROW Coil 566E180/524A-B180 with Standard 3-ROW Coil 566E180/524A-C180 with HIGH-CAPACITY 4-ROW Coil566E180/524A-B240 with Standard 3-ROW Coil 566E180/524A-C240 with HIGH-CAPACITY 4-ROW Coil566E240/524A-B240 with Standard 3-ROW Coil Unit 566E240566E240/524A-C240 with HIGH-CAPACITY 4-ROW Coil 566E240/524A-B300 with Standard 3-ROW Coil 566E240/524A-C300 with HIGH-CAPACITY 4-ROW CoilNominal Voltage Compressor Minimum OUTDOOR-AIR Operating Temperature 566E150-240 Units Minimum OUTDOOR-AIR Operating Temperature 566D150-240 UnitsApplication Data 566D150-240, 566E150-240 Operating LimitsSuction Line Piping Face-Split Coil Suction Liquid Line PipingRefrigerant Piping Sizes Double Suction Risers 566D, 566E150-240 Multiple Condensing Unit ArrangementsRooftop Installation 566D150-240 Ground Level Installation 566D150-240 Typical Piping and WiringGuide Specifications 566D150-240, 566E150-240 Guide Specifications 566D150-240, 566E150-240 Voltage 524A P B 120 000 GCCoil Option Nominal Cooling Tons 072Unit 524A 524A-B,C Units524A-B,C072-120 Unit Unit Weight524A-B,C150-240 B300 1020 C300 1050 524A-B,C300Unit Airflow 524A-B FAN Performance Data 0.0-1.2 in. wg ESP524A-B FAN Performance Data 1.4-2.4 in. wg ESP 1.2 in. wg ESP FAN Performance Data 524A-C with High Capacity CoilWith High Capacity Coil 1.4-2.4 in. wg ESP FAN Performance Data 524A-CFACTORY-SUPPLIED Filter Pressure Drop Accessory Plenum AIR Throw DataAccessory Pressure Drop in. wg Heating Correction Factors Hydronic Heating CapacitiesROW Unit Airflow HOT Water COIL†524A-B,C Standard Motors Unit Voltage FAN Motor Power Supply524A-B PH-Hz FLA MocpFLA Electrical Data524A-B,C Alternate Motors Electric Heater Data Electric Heater Data CAELHEAT017A00 CAELHEAT016A00CAELHEAT018A00 CAELHEAT019A00CAELHEAT026A00 CAELHEAT025A00CAELHEAT027A00 CAELHEAT028A00CAELHEAT035A00 CAELHEAT034A00CAELHEAT036A00 CAELHEAT037A00Application Data 524A FACTORY-INSTALLED Nozzle and Distributor DataFAN Motor Data Standard Motor Unit Size 524AStandard Drive Data Application Data 524AFAN Motor Data HIGH-STATIC Drive Data MEDIUM-STATIC Drive DataCommercial Packaged AIR-HANDLING Unit Guide Specifications 524AAir Discharge Plenum Guide Specifications 524AIndex

569F, 566E, 566D, 569D, 576C specifications

Bryant has long been recognized for its innovative heating and cooling solutions, and the Bryant 576C, 569D, 566D, 566E, and 569F models exemplify the brand's commitment to energy efficiency, comfort, and advanced technology. Each model is designed to cater to various residential and commercial heating and cooling needs, ensuring optimal performance and reliability.

The Bryant 576C is a highly efficient air conditioning unit that offers remarkable SEER ratings, making it an eco-friendly choice for homeowners. Its advanced technology includes a variable-speed compressor, which adjusts the cooling output based on the home’s requirements, ensuring maximum comfort while minimizing energy consumption. Additionally, its Quiet operation allows for a peaceful indoor environment, as the system operates at low sound levels even during peak performance.

The Bryant 569D heating system stands out for its durability and energy efficiency. Designed with a two-stage gas valve, it provides flexible heating output, allowing for improved temperature control. This model is equipped with an ECM blower motor, ensuring quiet operation and consistent airflow. Its efficiency ratings are impressive, providing significant savings on energy bills while maintaining an ideal indoor climate.

Similarly, the Bryant 566D model emphasizes performance and reliability. Its variable-speed blower motor enhances comfort levels by providing better humidity control and even heating throughout the living space. With an emphasis on high-quality construction materials, this model ensures a long lifespan, making it a wise investment for homeowners looking for effective heating solutions.

The Bryant 566E model incorporates state-of-the-art technology, including smart thermostat compatibility, which allows users to control their heating and cooling systems remotely. This feature enhances convenience and helps to optimize energy usage based on the occupants' schedules. With its excellent design and efficiency, the 566E is perfect for those seeking a modern heating solution without compromising on comfort.

Lastly, the Bryant 569F is ideal for homeowners wanting a balance between efficiency and performance. With an ENERGY STAR certification, this model provides reliable heating while keeping energy costs low. Its compact design makes it suitable for various spaces, and the integrated safety features ensure peace of mind for users.

In summary, whether you choose the Bryant 576C, 569D, 566D, 566E, or 569F, each model reflects a commitment to quality, efficiency, and innovation, ensuring that homeowners can achieve the perfect climate in their living spaces. These heating and cooling systems leverage advanced technologies that not only provide comfort but also promote energy savings and environmental responsibility.