Bryant 569F, 576C, 569D, 566E manual Typical Piping and Wiring, Ground Level Installation 566D150-240

Page 58

TYPICAL PIPING AND WIRING (cont)

566D/E150-240

LEGEND

NEC — National Electrical Code

TXV — Thermostatic Expansion Valve Piping

*Field supplied.

NOTES:

1.All piping must follow standard refrigerant piping techniques.

2.All wiring must comply with the applicable local and national codes.

3.Wiring and piping shown are general points-of-connection guides only and are not intended for, or to include all details for, a specific installation.

4.Liquid line solenoid valve (solenoid drop control) is recom- mended to prevent refrigerant migration to the compressor.

5.Internal factory-supplied TXVs not shown.

Ground Level Installation — 566D150-240

58

Image 58
Contents FEATURES/BENEFITS 524A AIR-HANDLING UnitsTable of Contents ARI* Capacity Ratings Estimated Sound Power Levels Lw 524A072-300Sound LEVELS, dB 569D/576C/566D,E FIELD-INSTALLED Accessories Options and Accessories566D, 566E, 569D, 569F, 576C FACTORY-INSTALLED Options Options and Accessories524A-B, C FACTORY-INSTALLED Options Options and AccessoriesCommercial Programmable Non-Programmable Thermostat 524A with Hot Water or Steam Coil 524A with Discharge Plenum, Return Grille, and Subbase524A with Economizer 524A with Condensate Trap II Select Condensing Unit AIR-HANDLER Combination Selection ProcedureIV Determine FAN RPM and BHP Brake Horsepower III Determine Sizes of Liquid and Suction LinesControls Operating SequencesTypical Wiring Schematics 569D090, 208/230-3-360 and 460-3-60 UnitsTypical Wiring Schematics 576C120, 208/230-3-60 and 460-3-60 UnitsModel Number Nomenclature 569D072-120, 576C120, 569F120 Units Physical DataUnit Dimensions 569D072-120, 576C120Dimensions 569D072Performance Data Condensing Unit Ratings569D072/524A-C072 with HIGH-CAPACITY 4-ROW Coil Performance DataCombination Ratings SHC569D072/524A-C090 with HIGH-CAPACITY 4-ROW Coil Combination Ratings2400 3000 3750 Condenser Temp F Unit 569D090569D090/524A-C072 with HIGH-CAPACITY 4-ROW Coil 569D090/524A-B072 with Standard 3-ROW Coil2205 3000 3750 Condenser 569D090/524A-C090 with HIGH-CAPACITY 4-ROW Coil569D090/524A-B090 with Standard 3-ROW Coil 3000 4000 5000 Condenser Unit 569D120569D120/524A-C120 with HIGH-CAPACITY 4-ROW Coil 569D120/524A-B120 with Standard 3-ROW Coil3750 5000 6250 Condenser 569D120/524A-C150 with HIGH-CAPACITY 4-ROW Coil569D120/524A-B150 with Standard 3-ROW Coil 576C120/524A-C120 with HIGH-CAPACITY 4-ROW Coil Unit 576C120576C120/524A-B120 with Standard 3-ROW Coil 576C120/524A-C150 with HIGH-CAPACITY 4-ROW Coil 576C120/524A-B150 with Standard 3-ROW Coil569F120/524A-C120 with HIGH-CAPACITY 4-ROW Coil Unit 569F120569F120/524A-B120 with Standard 3-ROW Coil 569F120/524A-C150 with HIGH-CAPACITY 4-ROW Coil 569F120/524A-B150 with Standard 3-ROW CoilElectrical Data Maximum Refrigerant Charge Operating Limits Minimum OUTDOOR-AIR Operating TemperatureApplication Data 569D072-120, 576C090-120, 569F120 Refrigerant Piping SizesTypical Piping and Wiring Rooftop Installation 569D072-120, 576C120Part 1 General Guide Specifications 569D072-120, 576C120Commercial AIR-COOLED Condensing Units Part 2 ProductsGuide Specifications 569D072-120, 576C120 Guide Specifications 569F120 Guide Specifications 569F120 566D E X 150 566D150-240 Units Physical Data 566E150-240 UnitsDimensions Dimensions 566D150-240, 566E150-240 Aluminum Coil UnitAir Temperature Entering Condenser F 100 105 115 Edb Unit 566D150566D150/524A-C150 with High Capacity 4-ROW Coil 566D150/524A-B150 with Standard 3-ROW Coil4500 6000 7500 Condenser 566D150/524A-C180 with High Capacity 4-ROW Coil566D150/524A-B180 with Standard 3-ROW Coil 566D180/524A-C180 with HIGH-CAPACITY 4-ROW Coil Unit 566D180566D180/524A-B180 with Standard 3-ROW Coil 000 10,000 Condenser 566D180/524A-C240 with HIGH-CAPACITY 4-ROW Coil566D180/524A-B240 with Standard 3-ROW Coil 500 10,000 12,500 Condenser Unit 566D240566D240/524A-C300 with HIGH-CAPACITY 4-ROW Coil 566D240/524A-B300 with Standard 3-ROW Coil566E150/524A-C120 with HIGH-CAPACITY 4-ROW Coil Unit 566E150566E150/524A-B120 with Standard 3-ROW Coil 566E150/524A-C150 with HIGH-CAPACITY 4-ROW Coil 566E150/524A-B150 with Standard 3-ROW Coil566E150/524A-C180 with HIGH-CAPACITY 4-ROW Coil 566E150/524A-B180 with Standard 3-ROW Coil566E180/524A-C150 with HIGH-CAPACITY 4-ROW Coil Unit 566E180566E180/524A-B150 with Standard 3-ROW Coil 566E180/524A-C180 with HIGH-CAPACITY 4-ROW Coil 566E180/524A-B180 with Standard 3-ROW Coil566E180/524A-C240 with HIGH-CAPACITY 4-ROW Coil 566E180/524A-B240 with Standard 3-ROW Coil566E240/524A-C240 with HIGH-CAPACITY 4-ROW Coil Unit 566E240566E240/524A-B240 with Standard 3-ROW Coil 566E240/524A-C300 with HIGH-CAPACITY 4-ROW Coil 566E240/524A-B300 with Standard 3-ROW CoilNominal Voltage Compressor Application Data 566D150-240, 566E150-240 Minimum OUTDOOR-AIR Operating Temperature 566D150-240 UnitsMinimum OUTDOOR-AIR Operating Temperature 566E150-240 Units Operating Limits Refrigerant Piping Sizes Double Suction Risers Face-Split Coil Suction Liquid Line Piping Suction Line Piping Multiple Condensing Unit Arrangements 566D, 566E150-240Rooftop Installation 566D150-240 Typical Piping and Wiring Ground Level Installation 566D150-240Guide Specifications 566D150-240, 566E150-240 Guide Specifications 566D150-240, 566E150-240 Coil Option 524A P B 120 000 GCVoltage Nominal Cooling Tons 072524A-B,C Units Unit 524AUnit Unit Weight 524A-B,C072-120524A-B,C150-240 524A-B,C300 B300 1020 C300 1050524A-B FAN Performance Data 0.0-1.2 in. wg ESP Unit Airflow524A-B FAN Performance Data 1.4-2.4 in. wg ESP FAN Performance Data 524A-C with High Capacity Coil 1.2 in. wg ESPFAN Performance Data 524A-C With High Capacity Coil 1.4-2.4 in. wg ESPAccessory Pressure Drop in. wg Accessory Plenum AIR Throw DataFACTORY-SUPPLIED Filter Pressure Drop ROW Unit Airflow Hydronic Heating CapacitiesHeating Correction Factors HOT Water COIL†524A-B PH-Hz Unit Voltage FAN Motor Power Supply524A-B,C Standard Motors FLA Mocp524A-B,C Alternate Motors Electrical DataFLA Electric Heater Data Electric Heater Data CAELHEAT018A00 CAELHEAT016A00CAELHEAT017A00 CAELHEAT019A00CAELHEAT027A00 CAELHEAT025A00CAELHEAT026A00 CAELHEAT028A00CAELHEAT036A00 CAELHEAT034A00CAELHEAT035A00 CAELHEAT037A00FAN Motor Data FACTORY-INSTALLED Nozzle and Distributor DataApplication Data 524A Standard Motor Unit Size 524AFAN Motor Data Application Data 524AStandard Drive Data MEDIUM-STATIC Drive Data HIGH-STATIC Drive DataGuide Specifications 524A Commercial Packaged AIR-HANDLING UnitGuide Specifications 524A Air Discharge PlenumIndex