Bryant 576C, 569D, 569F manual Guide Specifications 566D150-240, 566E150-240

Page 60

GUIDE SPECIFICATIONS — 566D150-240, 566E150-240 (cont)

566D/E150-240

Manual reset at the unit

Electrical overload protection through the use of def- inite-purpose contactors and calibrated, ambient compensated, magnetic trip circuit breakers. Circuit breakers shall open all 3 phases in the event of an overload in any one of the phases or a single-phase condition.

H.Operating Characteristics:

1.The capacity of the condensing unit shall meet or exceed_____Btuh at a suction temperature of_____ F. The power consumption at full load shall not exceed_____ kW.

2.The combination of the condensing unit and the evaporator or fan coil unit shall have a total net cool- ing capacity of _____ Btuh or greater at conditions of

_____ cfm entering-air temperature at the evaporator at _____ F wet bulb and _____ F dry bulb, and air entering the condensing unit at _____ F.

3.The system shall have an EER of _____ Btuh/Watt or greater at standard ARI conditions.

I.Electrical Requirements:

1.Nominal unit electrical characteristics shall be _____ v, 3-ph, 60 Hz. The unit shall be capable of satisfactory operation within voltage limits of _____ v to _____ v.

2.Unit electrical power shall be single point connection.

3.Unit control circuit shall contain a 24-v transformer for unit control, with capacity to operate an indoor fan interlock.

J.Special Features:

1.Low-Ambient Temperature Control (Factory-Installed Option or Field-Installed Accessory):

Control shall regulate fan motor speed in response to the saturated condensing temperature of the unit. The control shall allow the unit to operate down to an ambient temperature of –20 F.

2. Electric Solenoid Unloader Accessory:

Unloader valve piston, coil, and hardware shall be supplied to convert the pressure-operated compres- sor unloader to electric unloading.

3. Hail Guard Package:

Hail guard package shall protect coil against hail and other flying debris.

4. Condenser Coil Grille Package:

Grilles shall protect the condenser coils after unit installation.

5.Optional Condenser Coil Materials: a. Pre-Coated Aluminum-Fin Coils:

Shall have a durable epoxy-phenolic coating to provide protection in mildly corrosive coastal envi- ronments. Coating shall be applied to the alumi- num fin stock prior to the fin stamping process to create an inert barrier between the aluminum fin and copper tube. Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals.

b. E-Coated Aluminum-Fin Coils:

Shall have a flexible epoxy polymer coating uni- formly applied to all coil surface areas without material bridging between fins. Coating process shall ensure complete coil encapsulation. Color shall be high gloss black with gloss requirements of 60° of 65-90% per ASTM D523-89. Uniform dry film thickness from 0.8 to 1.2 mil on all surface areas including fin edges. Superior hardness characteristics of 2H per ASTM D3363-92A and cross hatch adhesion of 4B-5B per ASTM D3359-

93.Impact resistance shall be up to 160 in./lb (ASTM D2794-93). Humidity and water immersion resistance shall be up to a minimum of 1000 and

250hours respectively (ASTM-D2247-92 and ASTM D870-92). Corrosion durability shall be confirmed through testing to no less than 1000 hours salt spray per ASTM B117-90. Coil con- struction shall be aluminum-fins mechanically bonded to copper tubes.

6.Thermostat Control Accessory:

a.Commercial Electronic Thermostat with 7-day timeclock, auto-changeover, multi-stage capabil- ity, and large LCD temperature display.

b.Commercial Electronic Non-programmable Ther- mostat with auto-changeover, multi-stage capabil- ity, and large LCD temperature display.

7.Unit-Mounted, Non-Fused Disconnect Switch:

Shall be factory-installed, internally mounted. NEC and UL approved non-fused switch shall provide unit power shutoff. Shall be accessible from outside the unit and shall provide power off lockout capability. Not to be used when rooftop electrical rating exceeds 80 amperes.

8. Convenience Outlet:

Shall be factory-installed and internally mounted with easily accessible 115-v female receptacle. Shall include 15 amp GFI receptacle with independent fuse protection. Voltage required to operate conve- nience outlet shall be provided by a factory-installed step-down transformer. Shall be accessible from out- side the unit.

60

Image 60
Contents FEATURES/BENEFITS 524A AIR-HANDLING UnitsTable of Contents Estimated Sound Power Levels Lw 524A072-300 ARI* Capacity RatingsSound LEVELS, dB 569D/576C/566D,E Options and Accessories 566D, 566E, 569D, 569F, 576C FACTORY-INSTALLED OptionsFIELD-INSTALLED Accessories Options and AccessoriesOptions and Accessories 524A-B, C FACTORY-INSTALLED OptionsCommercial Programmable Non-Programmable Thermostat 524A with Discharge Plenum, Return Grille, and Subbase 524A with Hot Water or Steam Coil524A with Economizer 524A with Condensate Trap Selection Procedure IV Determine FAN RPM and BHP Brake HorsepowerII Select Condensing Unit AIR-HANDLER Combination III Determine Sizes of Liquid and Suction LinesControls Operating SequencesTypical Wiring Schematics 569D090, 208/230-3-360 and 460-3-60 UnitsTypical Wiring Schematics 576C120, 208/230-3-60 and 460-3-60 UnitsModel Number Nomenclature Physical Data 569D072-120, 576C120, 569F120 UnitsUnit Dimensions 569D072-120, 576C120Dimensions 569D072Performance Data Condensing Unit RatingsPerformance Data Combination Ratings569D072/524A-C072 with HIGH-CAPACITY 4-ROW Coil SHCCombination Ratings 569D072/524A-C090 with HIGH-CAPACITY 4-ROW Coil2400 3000 3750 Condenser Unit 569D090 569D090/524A-C072 with HIGH-CAPACITY 4-ROW CoilTemp F 569D090/524A-B072 with Standard 3-ROW Coil569D090/524A-C090 with HIGH-CAPACITY 4-ROW Coil 2205 3000 3750 Condenser569D090/524A-B090 with Standard 3-ROW Coil Unit 569D120 569D120/524A-C120 with HIGH-CAPACITY 4-ROW Coil3000 4000 5000 Condenser 569D120/524A-B120 with Standard 3-ROW Coil569D120/524A-C150 with HIGH-CAPACITY 4-ROW Coil 3750 5000 6250 Condenser569D120/524A-B150 with Standard 3-ROW Coil Unit 576C120 576C120/524A-C120 with HIGH-CAPACITY 4-ROW Coil576C120/524A-B120 with Standard 3-ROW Coil 576C120/524A-C150 with HIGH-CAPACITY 4-ROW Coil 576C120/524A-B150 with Standard 3-ROW CoilUnit 569F120 569F120/524A-C120 with HIGH-CAPACITY 4-ROW Coil569F120/524A-B120 with Standard 3-ROW Coil 569F120/524A-C150 with HIGH-CAPACITY 4-ROW Coil 569F120/524A-B150 with Standard 3-ROW CoilElectrical Data Operating Limits Minimum OUTDOOR-AIR Operating Temperature Application Data 569D072-120, 576C090-120, 569F120Maximum Refrigerant Charge Refrigerant Piping SizesTypical Piping and Wiring Rooftop Installation 569D072-120, 576C120Guide Specifications 569D072-120, 576C120 Commercial AIR-COOLED Condensing UnitsPart 1 General Part 2 ProductsGuide Specifications 569D072-120, 576C120 Guide Specifications 569F120 Guide Specifications 569F120 566D E X 150 566D150-240 Units Physical Data 566E150-240 UnitsDimensions Dimensions 566D150-240, 566E150-240 Aluminum Coil UnitAir Temperature Entering Condenser F 100 105 115 Unit 566D150 566D150/524A-C150 with High Capacity 4-ROW CoilEdb 566D150/524A-B150 with Standard 3-ROW Coil566D150/524A-C180 with High Capacity 4-ROW Coil 4500 6000 7500 Condenser566D150/524A-B180 with Standard 3-ROW Coil Unit 566D180 566D180/524A-C180 with HIGH-CAPACITY 4-ROW Coil566D180/524A-B180 with Standard 3-ROW Coil 566D180/524A-C240 with HIGH-CAPACITY 4-ROW Coil 000 10,000 Condenser566D180/524A-B240 with Standard 3-ROW Coil Unit 566D240 566D240/524A-C300 with HIGH-CAPACITY 4-ROW Coil500 10,000 12,500 Condenser 566D240/524A-B300 with Standard 3-ROW CoilUnit 566E150 566E150/524A-C120 with HIGH-CAPACITY 4-ROW Coil566E150/524A-B120 with Standard 3-ROW Coil 566E150/524A-C150 with HIGH-CAPACITY 4-ROW Coil 566E150/524A-B150 with Standard 3-ROW Coil566E150/524A-C180 with HIGH-CAPACITY 4-ROW Coil 566E150/524A-B180 with Standard 3-ROW CoilUnit 566E180 566E180/524A-C150 with HIGH-CAPACITY 4-ROW Coil566E180/524A-B150 with Standard 3-ROW Coil 566E180/524A-C180 with HIGH-CAPACITY 4-ROW Coil 566E180/524A-B180 with Standard 3-ROW Coil566E180/524A-C240 with HIGH-CAPACITY 4-ROW Coil 566E180/524A-B240 with Standard 3-ROW CoilUnit 566E240 566E240/524A-C240 with HIGH-CAPACITY 4-ROW Coil566E240/524A-B240 with Standard 3-ROW Coil 566E240/524A-C300 with HIGH-CAPACITY 4-ROW Coil 566E240/524A-B300 with Standard 3-ROW CoilNominal Voltage Compressor Minimum OUTDOOR-AIR Operating Temperature 566D150-240 Units Minimum OUTDOOR-AIR Operating Temperature 566E150-240 UnitsApplication Data 566D150-240, 566E150-240 Operating LimitsFace-Split Coil Suction Liquid Line Piping Refrigerant Piping Sizes Double Suction RisersSuction Line Piping Multiple Condensing Unit Arrangements 566D, 566E150-240Rooftop Installation 566D150-240 Typical Piping and Wiring Ground Level Installation 566D150-240Guide Specifications 566D150-240, 566E150-240 Guide Specifications 566D150-240, 566E150-240 524A P B 120 000 GC VoltageCoil Option Nominal Cooling Tons 072524A-B,C Units Unit 524AUnit Unit Weight 524A-B,C072-120524A-B,C150-240 524A-B,C300 B300 1020 C300 1050524A-B FAN Performance Data 0.0-1.2 in. wg ESP Unit Airflow524A-B FAN Performance Data 1.4-2.4 in. wg ESP FAN Performance Data 524A-C with High Capacity Coil 1.2 in. wg ESPFAN Performance Data 524A-C With High Capacity Coil 1.4-2.4 in. wg ESPAccessory Plenum AIR Throw Data Accessory Pressure Drop in. wgFACTORY-SUPPLIED Filter Pressure Drop Hydronic Heating Capacities Heating Correction FactorsROW Unit Airflow HOT Water COIL†Unit Voltage FAN Motor Power Supply 524A-B,C Standard Motors524A-B PH-Hz FLA MocpElectrical Data 524A-B,C Alternate MotorsFLA Electric Heater Data Electric Heater Data CAELHEAT016A00 CAELHEAT017A00CAELHEAT018A00 CAELHEAT019A00CAELHEAT025A00 CAELHEAT026A00CAELHEAT027A00 CAELHEAT028A00CAELHEAT034A00 CAELHEAT035A00CAELHEAT036A00 CAELHEAT037A00FACTORY-INSTALLED Nozzle and Distributor Data Application Data 524AFAN Motor Data Standard Motor Unit Size 524AApplication Data 524A FAN Motor DataStandard Drive Data MEDIUM-STATIC Drive Data HIGH-STATIC Drive DataGuide Specifications 524A Commercial Packaged AIR-HANDLING UnitGuide Specifications 524A Air Discharge PlenumIndex

569F, 566E, 566D, 569D, 576C specifications

Bryant has long been recognized for its innovative heating and cooling solutions, and the Bryant 576C, 569D, 566D, 566E, and 569F models exemplify the brand's commitment to energy efficiency, comfort, and advanced technology. Each model is designed to cater to various residential and commercial heating and cooling needs, ensuring optimal performance and reliability.

The Bryant 576C is a highly efficient air conditioning unit that offers remarkable SEER ratings, making it an eco-friendly choice for homeowners. Its advanced technology includes a variable-speed compressor, which adjusts the cooling output based on the home’s requirements, ensuring maximum comfort while minimizing energy consumption. Additionally, its Quiet operation allows for a peaceful indoor environment, as the system operates at low sound levels even during peak performance.

The Bryant 569D heating system stands out for its durability and energy efficiency. Designed with a two-stage gas valve, it provides flexible heating output, allowing for improved temperature control. This model is equipped with an ECM blower motor, ensuring quiet operation and consistent airflow. Its efficiency ratings are impressive, providing significant savings on energy bills while maintaining an ideal indoor climate.

Similarly, the Bryant 566D model emphasizes performance and reliability. Its variable-speed blower motor enhances comfort levels by providing better humidity control and even heating throughout the living space. With an emphasis on high-quality construction materials, this model ensures a long lifespan, making it a wise investment for homeowners looking for effective heating solutions.

The Bryant 566E model incorporates state-of-the-art technology, including smart thermostat compatibility, which allows users to control their heating and cooling systems remotely. This feature enhances convenience and helps to optimize energy usage based on the occupants' schedules. With its excellent design and efficiency, the 566E is perfect for those seeking a modern heating solution without compromising on comfort.

Lastly, the Bryant 569F is ideal for homeowners wanting a balance between efficiency and performance. With an ENERGY STAR certification, this model provides reliable heating while keeping energy costs low. Its compact design makes it suitable for various spaces, and the integrated safety features ensure peace of mind for users.

In summary, whether you choose the Bryant 576C, 569D, 566D, 566E, or 569F, each model reflects a commitment to quality, efficiency, and innovation, ensuring that homeowners can achieve the perfect climate in their living spaces. These heating and cooling systems leverage advanced technologies that not only provide comfort but also promote energy savings and environmental responsibility.