V-Belt Maintenance
With extended use,
To re-tension/replace the V-belts:
1.DISCONNECT SAW FROM POWER!
2.Raise the front guard up, and remove the inner blade guard to access the pivot arm assemblies and motors (see Figure 39).
Figure 39. Guards removed to access pivot arm
assemblies and motors.
The teeth of saw blades are sharp and can easily cut fingers and hands. Always wear heavy leath- er gloves when handling saw blades.
3.Use a 14mm wrench on the inner arbor nut (see Figure 40) and a 19mm wrench on the arbor bolt to remove the arbor bolt, arbor flange, and saw blade.
Arbor Bolt |
|
| |
Inner Arbor Nut | |||
& Flange |
| ||
|
| ||
|
|
|
Figure 40. Blade arbor bolt, flange, and nut (left
side shown).
Note: The left saw blade has a
4.Use a 10mm hex wrench to remove the two cap screws, lock washers, and the side blade guard (see Figure 41).
Side Blade Guard |
Cap Screws |
Figure 41. Side blade guard and cap screws.
G0641 Double Miter Saw |