Grizzly G0641 Lubrication, To lubricate the pneumatic system, To lubricate the lower pivot arms

Page 29

lubrication

Lubrication

For the many moving parts of the Model G0641, there are three lubrication systems: 1) the pneu- matic oiler attached to the air regulator-lubricator,

2)the lower pivot arm automatic oil system, and

3)manual lubrication of the arbor housings and remaining pivot points.

The pneumatic oiler injects lubrication into the air system as it is used to keep the main and hold- down pneumatic rams moving smoothly.

To lubricate the pneumatic system:

1.DISCONNECT SAW FROM AIR SUPPLY!

2.Fill the oil reservoir with ISO-VG32 tool oil (see Figure 34).

Flow Adjustment screw

Mixture Bubble

Fill Plug

Figure 34. Pneumatic oiler.

3.Tighten the flow adjustment screw clockwise until it stops, then open it 12 turn.

Note: The goal is to inject enough lubrication into the air system to keep a very light coat of oil on the surface of the rams during opera- tion.

G0641 Double Miter Saw

The lower pivot arm oil system is adjusted so that an adequate flow of lubricant moves through the oil lines to the sides of the lower pivot arms.

To lubricate the lower pivot arms:

1.Slide the fill plate aside to add ISO-VG32 tool oil to the reservoir (see Figure 35).

Flow

Valve

Adjustment

Lever

Screw

 

Fill Plate

 

Figure 35. Lower pivot arm oil reservoir.

2.Turn the flow adjustment screw counterclock- wise to increase the flow rate of lubricant.

3.Flip the valve lever up, as shown in Figure 35, to start the flow of lubricant from the bot- tom of the reservoir into the oil line.

Note: We recommend a setting of one drop per 20 pivot arm cycles. Have an assistant count the drops while you cycle the blades lowering and raising to reach this setting.

4.Flip the valve levers down to close off the flow of lubricant when the machine is not in use.

NOTICE

Failure to perform proper lubrication main- tenance on this machine will lead to prema- ture wear of the moving parts, and will void the warranty.

-27-

Image 29
Contents Model G0641 Double Miter SAW Page Table of Contents Contact Info IntroductionForeword Machine Data Sheet Model G0641 identification IdentificationSafety Instructions for Machinery G0641 Double Miter Saw Safety Instructions for Double Miter Saws Circuit Requirements 220V Single-PhaseSetup Safety SetupItems Needed for Setup UnpackingInventory Figures Qty InventorySite Considerations Clean UpTo move the machine Moving & Placing MachineBolting to Concrete Floors Mounting to Shop FloorTo assemble the double miter saw AssemblyTo connect the saw to compressed air Air SupplyTo connect a dust collection hose Dust CollectionTo test run the machine Test RunTo make a cut Operation SafetyOperations Hold-downs Lowering Speeds To adjust the lowering and raising rate of the saw bladesTo adjust the lowering rate of the hold- downs Fence Stop To replace the saw blades Replacing BladesG1955-OxiSolvBlade & Bit Cleaner AccessoriesG8982-Shop Fox Roller Table Forest ChopMaster H4751-12, 80 TPI, 1 ArborT20448T20452 T20501 T20456 H0736 BoeshieldH8888-Kreg Framing Table G3326-BesseyAngle ClampSchedule MaintenanceCleaning To lubricate the lower pivot arms LubricationTo lubricate the pneumatic system To lubricate the main ram pivot point To lubricate the blade arbor housingsTo re-tension/replace the V-belts Belt MaintenancePage Troubleshooting ServiceMiter Saw Operations Pneumatic System To realign the pivot arm assemblies Aligning Pivot Arm AssemblyPneumatic Limit Switch Junction Electrical Wiring DiagramLeft-hand Motor Wiring DiagramPneumatic System Diagram Cabinet Breakdown PartsDescription Cabinet Parts ListDrive System Breakdown Drive System Parts List Pivot Linkage Breakdown & Parts List Extension Wings Breakdown & Parts List Electrical & Lubrication Systems Breakdown Electrical & Lubrication Systems Parts List Pneumatic System Breakdown Pneumatic System Parts List Label Placement & List G0641 Double Miter Saw Page Page Warranty and Returns