Grizzly G0605X/G0606X owner manual Saw Blade, To install the blade

Page 24

3.Place the extension table assembly upright with the feet on the ground, align the slots in the extension table bracket with the rear rail mounting holes, then fasten the table to the rail with two M8-1.25 x 16 flange bolts and hex nuts shown in Figure 20.

Flange Bolts

Bracket

Figure 20. Outfeed table fastened to rear rail.

4.Secure the lower shelf brackets to the sup- port legs and cabinet with four M6-1 x 12 hex bolts, four flat washers and two hex nuts.

5.Install the lower shelf on the brackets.

6.Place the 913/8" fence tube over the 913/8" front rail and secure with nine M8-1.25 x 12 flange bolts as shown in Figure 21.

Flange Bolt

Figure 21. Fence tube mounted to front fence

rail.

Saw Blade

The saw blade is extremely sharp. Use extra care when handling the blade or working near it. Serious injury is possible.

Review this section, even if your saw blade came pre-installed.

To install the blade:

1.DISCONNECT THE SAW FROM POWER!

2.Remove the table insert, blade guard, and splitter–if previously installed.

3.Use the arbor wrenches to loosen and remove the arbor nut, flange, and blade.

Note: The arbor nut has right hand threads; turn it counterclockwise to loosen.

4.Slide the blade over the arbor with the teeth facing the front of the saw, as shown in Figure 22.

Teeth Direction

& Blade Rotation

Front Of Saw

Figure 22. Correct blade direction.

5.Re-install the arbor flange and the arbor nut, and tighten them against the blade with the wrench included with the saw. DO NOT over- tighten.

-22-

G0605X/G0606X Extreme Series 12" Table Saw

Image 24
Contents Extreme Series Table SAW Page Table of Contents Accessories Maintenance Introduction ForewordContact Info Machine Data Sheet Model G0606X 12 Extreme Series Table SAW Identification G0606X identificationSafety Safety Instructions for MachineryAlways Lock Mobile Bases if Used Before Operating Machinery Safety Instructions for Table Saws Preventing Kickback Protecting Yourself From KickbackBelow are tips to avoid the most common causes of kickback Glossary of Terms Power Connection Device Circuit RequirementsOperation Full Load Amperage Draw DrawPhase Converter Precaution 440V ConversionExtension Cords 220V Only SET UP Set Up SafetyItems Needed for Set Up UnpackingMachine Inventory Fence InventoryFence Rail Inventory Extension Table Inventory Outfeed Table InventoryHardware Recognition Chart Clean Up Placement LocationSite Considerations Floor LoadTo install the front and rear rails Extension TableComponents and Hardware Needed Qty Foot installed on support leg To install the outfeed table Outfeed TableTo install the blade Saw BladeTo install and adjust the table insert Arbor Table InsertTo change the arbor To install the blade guard Blade Guard SplitterOn/Off Switch Riving KnifeMiter Gauge Fence Components Dust CollectionTo connect a dust collection hose Recommended Adjustments Recommended adjustment checklistTest Run To test run the machineExample of switching incoming power Operation Safety OperationsBasic Controls Disabling On/Off Switch Ripping blade featuresCrosscut blade features Combination blade featuresLaminate blade features Dado BladesWorkpiece Inspection Non-Through Through CutsNon-Through Cuts Through CutsRipping Typical ripping operationTo make a crosscut using the miter gauge Crosscutting Miter CutsTo perform a miter cut Dado Cutting To use a standard saw blade to cut dadoes Rabbet Cutting To cut rabbets with the dado bladeTo cut rabbets with the standard blade Resawing Resaw Barrier Auxiliary FenceResawing Operations Components Needed for ResawingPage Accessories G7895-Citrus DegreaserH1234-Table Saw Bench Guide H7583-Grizzly Tenoning JigG7581-Superbar G7582-Master Plate G2370-SHOP FOX Board BuddiesMaintenance CleaningSchedule LubricationService TroubleshootingMotor & Electrical Table Saw Operations Replacing Flat Belt Tools Needed QtyTo remove the flat belt To install the new belt Blade Tilt Stops To set the 90 stop boltTo set the 45 stop bolt To adjust the tilt indicator arrow Digital ReadoutTo set the digital readout To adjust the blade parallel to the miter slot Miter Slot to Blade ParallelismShim procedure diagram a Adjusting Fence To adjust the blade by moving the tableBlade Alignment Square and HeightMiter Gauge G0605X/G0606X Electrical Components G0605X motor junction boxG0605X Wiring Diagram G0606X magnetic switch prewired to Phase G0606X Electrical ComponentsG0606X Wiring Diagram G0606X Wiring Diagram Cabinet, Motor & Main Table Breakdown Cabinet, Motor & Main Table Parts List DescriptionDescription Blade Guard Assembly Breakdown Blade Guard Parts List Fence Assembly Breakdown Fence Parts List Miter Gauge Assembly Breakdown Miter Gauge Parts List Extension Table Assembly Outfeed Table Assembly Breakdown Outfeed Table Parts List Guard and ANTI-KICK Back Label Warranty and Returns Page Page