Grizzly G0605X/G0606X owner manual Arbor Table Insert, To change the arbor

Page 25

Arbor

 

Table Insert

 

 

 

 

 

 

A1" or 5/8" arbor can be installed on the table saw, depending upon the arbor size of the blade you want to install.

To change the arbor:

1.DISCONNECT THE SAW FROM POWER!

2.Remove the table insert, blade guard and splitter or riving knife, arbor nut, arbor flange, and blade.

3.Raise the arbor all the way up.

4.Hold the arbor shaft with the arbor wrench and, using a 5mm hex wrench, remove the cap screw from the end of the arbor, as shown in Figure 23.

Arbor

Arbor Wrench

Figure 23. Removing arbor.

Note: Gently tap the arbor with a rubber mal- let to unseat it if it is hard to remove.

5.Slide the arbor out of the arbor shaft and rein- stall the new arbor in the same manner that the old one was removed. Make sure the new arbor is securely tightened in the arbor shaft before reinstalling the blade.

G0605X/G0606X Extreme Series 12" Table Saw

You MUST install the table insert before operating the table saw.

Components and Hardware Needed:

Qty

Table Insert

1

Flat Head Screw M5-.8 x 20

1

To install and adjust the table insert:

 

1.DISCONNECT THE SAW FROM POWER!

2.Place the table insert into the table and tight- en the screw shown in Figure 24.

Table Insert

Screw

Figure 24. Table insert screw.

Note: Do not overtighten the table insert screw. If you have questions, contact Technical Support.

3.Place a straightedge across the table and the table insert.

4.Use a 3mm hex wrench and straightedge to adjust the table insert flush with the table as shown in Figure 25.

Figure 25. Adjusting the table insert.

The table insert must be flush with the table top or the workpiece will hit the edge of the table insert at the beginning of the cut.

-23-

Image 25
Contents Extreme Series Table SAW Page Table of Contents Accessories Maintenance Foreword IntroductionContact Info Machine Data Sheet Model G0606X 12 Extreme Series Table SAW G0606X identification IdentificationSafety Instructions for Machinery SafetyAlways Lock Mobile Bases if Used Before Operating Machinery Safety Instructions for Table Saws Protecting Yourself From Kickback Preventing KickbackBelow are tips to avoid the most common causes of kickback Glossary of Terms Circuit Requirements Power Connection DeviceOperation Full Load Amperage Draw Draw440V Conversion Phase Converter PrecautionExtension Cords 220V Only Set Up Safety SET UPItems Needed for Set Up UnpackingFence Inventory Machine InventoryFence Rail Inventory Outfeed Table Inventory Extension Table InventoryHardware Recognition Chart Placement Location Clean UpSite Considerations Floor LoadExtension Table To install the front and rear railsComponents and Hardware Needed Qty Foot installed on support leg Outfeed Table To install the outfeed tableSaw Blade To install the bladeArbor Table Insert To install and adjust the table insertTo change the arbor Blade Guard Splitter To install the blade guardRiving Knife On/Off SwitchMiter Gauge Dust Collection Fence ComponentsTo connect a dust collection hose Recommended adjustment checklist Recommended AdjustmentsTest Run To test run the machineExample of switching incoming power Operations Operation SafetyBasic Controls Ripping blade features Disabling On/Off SwitchCrosscut blade features Combination blade featuresDado Blades Laminate blade featuresNon-Through Through Cuts Workpiece InspectionNon-Through Cuts Through CutsTypical ripping operation RippingCrosscutting Miter Cuts To make a crosscut using the miter gaugeTo perform a miter cut Dado Cutting To use a standard saw blade to cut dadoes To cut rabbets with the dado blade Rabbet CuttingTo cut rabbets with the standard blade Resawing Auxiliary Fence Resaw BarrierComponents Needed for Resawing Resawing OperationsPage G7895-Citrus Degreaser AccessoriesH1234-Table Saw Bench Guide H7583-Grizzly Tenoning JigG2370-SHOP FOX Board Buddies G7581-Superbar G7582-Master PlateCleaning MaintenanceSchedule LubricationTroubleshooting ServiceMotor & Electrical Table Saw Operations Tools Needed Qty Replacing Flat BeltTo remove the flat belt To install the new belt To set the 90 stop bolt Blade Tilt StopsTo set the 45 stop bolt Digital Readout To adjust the tilt indicator arrowTo set the digital readout Miter Slot to Blade Parallelism To adjust the blade parallel to the miter slotShim procedure diagram a To adjust the blade by moving the table Adjusting FenceBlade Alignment Square and HeightMiter Gauge G0605X motor junction box G0605X/G0606X Electrical ComponentsG0605X Wiring Diagram G0606X Electrical Components G0606X magnetic switch prewired to PhaseG0606X Wiring Diagram G0606X Wiring Diagram Cabinet, Motor & Main Table Breakdown Description Cabinet, Motor & Main Table Parts ListDescription Blade Guard Assembly Breakdown Blade Guard Parts List Fence Assembly Breakdown Fence Parts List Miter Gauge Assembly Breakdown Miter Gauge Parts List Extension Table Assembly Outfeed Table Assembly Breakdown Outfeed Table Parts List Guard and ANTI-KICK Back Label Warranty and Returns Page Page