Bard QW3S1, QW4S1, QW5S1, QW2S1 installation instructions Water Well System

Page 37

Page

Manual

37 of 46

2100-532B

FIGURE 25

WATER WELL SYSTEM

WELL CAP

 

 

 

ELECTRICAL LINE

 

 

 

PITLESS ADAPTER

 

 

 

TO PRESSURE

 

 

 

TANK

 

 

 

WATER SUPPLY

 

 

 

LINE

 

 

 

15' to 20'

 

 

 

DEEP

 

 

GRAVEL FILL

DROP PIPE

 

 

 

LAKE

WATER LEVEL

 

PERFORATED

or

 

 

 

PLASTIC CASING

POND

 

 

 

 

 

12' to 15'

 

 

SUBMERSIBLE

 

 

 

 

 

 

PUMP

Image 37
Contents Bryan, Ohio QW2S1 QW3S1 QW4S1 QW5S1Contents Figures For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsQW Model Nomenclature Electrical SpecificationsUnit Dimensions Unit Removal from Skid Shipping DamageHandling Unit After Removal from Skid Removal of Unit from SkidGeneral Minimum Installation HeightProper Handling of Unit After Removal from Skid Installation of Unit Through Wall with Wall Sleeve Ducted Application Installation with Free Blow PlenumFilters Duct WorkCondensate Drain Supply Duct ConnectionsOptional Rear Drain Condensate DrainCommercial Room Ventilator Option Rear Drain TOP ViewRemoval of the Q-TEC Energy Recovery Ventilator TEC Energy Recovery Ventilator OptionMounting the Unit Installation InstructionsRemoving Locking Screws from Wheels Unit Mounting Without Ventilation Wall Sleeve Component Location Wiring LOW Voltage Wiring Wiring Main PowerOperating Voltage Range Wall ThermostatsLOW Voltage Connections Blower Motor LOW Voltage Wire Harness PlugLOW Voltage Connections for DDC Control 24VAC Remote Thermostat Wiring Diagram OptionRemote Thermostat Wiring Diagram Thermostat Option Plug #1 Start UP AdjustmentsDescription of Standard Equipment Compressor Control ModuleImportant Installer Note Optional CFM Service HintsPhase Monitor Delay on Make TimingPiping Access to Unit Pressure Service PortsIndoor Blower Performance Fluid Connections on Unit with Ventilation Wall Sleeve Opening Rear of Unit Fluid Access From FloorFluid Connections on Unit Without Ventilation Wall Sleeve Flow Rate for Various Fluids Pressure TableOptional Accessories Copper Water Coil Application Circulation System DesignCirculation System Water Temperature and Pressure Procedure Start UP Procedure for Closed Loop SystemPerformance Model DORFC-2 Loop Pump Module Performance Model DORFC-1 Loop Pump ModuleWater Connections Piping DiagramConstant Flow Valves Well Pump Sizing System Start UP Procedure for Open Loop ApplicationsWater Corrosion Remedies of Water ProblemsCleaning Water Coil Lake and Pond InstallationsWater Well System Water Flow and Pressure Drop Cooling Tower / Boiler ApplicationWater Source Heat Pump Water Source Heat Pump Unbrazing System Components ServiceDon’t Troubleshooting GE ECM MotorsReplacing ECM Control Module Troubleshooting GE ECM Motors CONT’DCommon Cause Occasional Cause Denotes Ground Source Heat Pump Performance Report Following Information is Needed To Check Performance of Unit