Woodstock W1828 owner manual Miter Gauge Calibration, Table Tilt Calibration

Page 26
Using a try square or machinist’s square, set one edge on the table surface and the other against the face of the disc, as shown in Figure 21.

Model W1828 (For Machines Mfg. Since 4/11)

Miter Gauge Calibration

The miter gauge should be perpendicular to the face of the disc when it is set at 90° and mounted in the table slot. If not, follow this procedure.

Tools Needed

Qty

Try Square or Machinist's Square

1

Phillips Screwdriver #1

1

To calibrate the miter gauge, do these steps:

 

1.DISCONNECT MACHINE FROM POWER!

2.Use a try square or machinist’s square with one edge against the face of the miter gauge and the other

against the disc face, as shown in Figure 20.

Figure 20. Squaring miter gauge to disc.

3.Loosen the lock knob on the miter gauge and adjust the face of the miter gauge so it is flush with the edge of the square, tighten the gauge lock knob, and verify the setting.

4.Loosen the degree scale pointer, position the pointer on 90˚, then re-tighten the screw.

5.Re-check the miter scale accuracy with the square.

SERVICE

Table Tilt Calibration

When the table tilt is set to 0˚, the table should be positioned perpendicular to the sanding disc face. If it is not, follow this procedure.

To calibrate the table tilt, do these steps:

1.DISCONNECT MACHINE FROM POWER!

2.

3.Loosen the table tilt lock handles and adjust the table angle until it is perfectly perpendicular to the disc, then tighten the lock handles while holding the table in place.

4.If the angle pointer stickers on both ends do not point to 0˚, remove them and place them on the trunnion so they point to 0˚.

5.Recheck the scale accuracy with the square.

-24-

Figure 21. Squaring the table.

Image 26
Contents OWNERS MANUAL Page Contents Introduction Woodstock Technical SupportShop FOX 12 Disc Sander Model W1828 For Machines Mfg. Since 4/11 Controls and Features Work Table Rubber FootStandard Machinery Safety Instructions SafetyFor Your Own Safety Read Manual Before Operating Machine Safety Additional Safety for Disc Sanders 60 Hz Electrical110V/120V AmpsGrounding & Plug Requirements 50 ftUnpacking SetupNeeded for Setup InventoryMachine Placement Cleaning Machine Working clearancesBench Mounting Dust CollectionPower Connection Power sourceProjectiles thrown from this machine Safety glasses to reduce the riskTest Run Could cause serious eye injury. WearBasic Controls OperationsGeneral Disabling ON/OFF Switch Operation OverviewGrit Type Choosing SandpaperStock Inspection Requirements Before sanding, inspect all workpieces for the followingAttaching Sandpaper To attach the sandpaper disc, do these stepsDisconnect Sander from Power Disc SandingModel Grit AccessoriesDisc Sander Accessories Size ModelTable & Base MaintenanceCleaning LubricationTools Needed ServiceTable/Disc Parallelism To make the table and sanding disc parallel, do these stepsTo calibrate the miter gauge, do these steps Miter Gauge CalibrationTable Tilt Calibration Against the disc face, as shown in FigureTroubleshooting Problem Possible CauseInstall a coarse grit sandpaper, or strip coating off Electrical Safety Instructions Wiring Diagram Color KEYWiring Diagram Stop22-3 22-1 22-5 22-4 22-2 16-1 Main Parts List DescriptionPage Woodstock international inc. p.o. box Bellingham, Wa Warranty High Quality Machines and Tools