Delta D25886 Know Your Air Compressor Description of Operation, Pressure, Regulator, Tank

Page 12

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch: Turn this switch ON to provide automatic power to the pressure switch and OFF to remove

power at the end of each use.

 

On/Auto/Off

 

 

 

Pressure

Pressure Switch: The pressure switch

 

 

 

Switch

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

 

automatically starts the motor when the

 

 

 

 

 

 

 

 

 

 

 

air tank pressure drops below the factory

 

 

 

 

 

 

 

 

 

 

 

set “cut-in” pressure. It stops the motor

 

 

 

 

 

 

 

 

 

 

 

when the air tank pressure reaches the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regulator

factory set “cut-out” pressure.

 

 

 

Safety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Valve: If the pressure switch does

 

 

 

Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

not shut off the air compressor at its

 

 

 

 

 

 

 

 

 

 

 

“cut-out” pressure setting, the safety

 

 

 

 

 

 

 

 

 

 

 

valve will protect against high pressure by

 

 

 

 

 

 

 

 

 

 

 

“popping out” at its factory set pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

Tank

 

(slightly higher than the pressure switch

 

 

 

 

 

 

 

Pressure Gauge

 

Pressure Gauge

 

“cut-out” setting).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Drain Valve

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve: When the air compressor is operating, the

 

check valve is “open”, allowing compressed air to enter

 

the air tank. When the air compressor reaches “cut-out”

 

pressure, the check valve “closes”, allowing air pressure

Check Valve

to remain inside the air tank.

D25886

12- ENG

Image 12
Contents Oil-Free Air Compressor Safety Guidelines Definitions Serious injury Result in property damageHazard What Could HappenHOW to Prevent IT What can HappenHazard What can Happen HOW to Prevent IT Never operate the compressor withBelt can cause serious injury if they Fire, Inhalation, Damage to Vehicle Surfaces Specifications AccessoriesGlossary Duty CycleInstallation Assembly for Tank unitsLocation of the Air Compressor Compressor Saddle Screw HandleTab Wheel NutExtension Cords Volt U.S.A. PlugVoltage and Circuit Protection Operation Know Your Air Compressor Description of OperationPressure RegulatorHow to Stop Before StartingBefore Each Start-Up Maintenance How to StartTo Check Safety Valve Customer ResponsibilitiesService and Adjustments To Replace or Clean Check ValveUnplug outfit Storage To Replace RegulatorTroubleshooting Pressure reading Problem Cause Correction AIR Compressor Diagram Parts List Part Number DescriptionAIR Compressor Pump Diagram Not Shown Kits AvailableLimited Warranty Compresor de Aire Sin Aceite Resultar en lesiones menores o ModeradasLesiones serias Instrucciones Importantes DE Seguridad Agregados Y Accesorios Códigos locales y federales, previo al Advertencia Riesgo DE Quemaduras ¿QUÉ Puede OCURRIR? Advertencia Riesgo DE Caida ¿QUÉ Puede OCURRIR?Advertencia Riesgo DE Operación Insegura ¿QUÉ Puede OCURRIR? Glosario Ciclo DE ServicioEspecificaciones AccesoriosInstalación Será necesario sujetar o soportar un lado delEnchufe de 120 V, EE.UU Enchufe de 240 V, EE.UUCables de extensión eléctrica Protección del voltaje y del circuito Operación Conozca su compresor de aireDescripción de operaciones Manómetro deCómo utilizar su unidad Cómo detenerlaAntes de poner en marcha Antes de cada puesta en marchaMantenimiento Cómo poner en marchaResponsabilidades del cliente Cómo verificar la válvula de seguridadServicio Y Ajustes Para reemplazar o limpiar la válvula reguladoraAfloje la tuerca de la salida del Tubo y muévala hacia el costadoAlmacenaje Para reemplazar el reguladorAire, originando un riesgo de ruptura de sus paredes Guía DE Duagnóstico DE Problemas Sobre la soldadura o cosaAire, ello lo debilitará. El Tanque podría romperse oDesciende cuando El motor no funciona Diagrama DEL Compresor DE AIR Lista DE Piezas Clave No No. De Pieza DescripciónDiagrama DE LA Bomba DEL Compresor No mostrado Kits disponiblesGarantía Limitada AÑO Garantía limitada sobre todos los serviciosCompresseur dair sans huile Ou la mort MoyennesDes dommages à la propriété Avertissement Risque D’EXPLOSION OU D’INCENDIE PréventionAvertissement Risque D’ÉCLATEMENT RisqueAvertissement Risque DE Projection D’OBJETS Avertissement Risque DE Choc Électrique Avertissement Risque PAR InhalationAvertissement Risque DE Brûlures Avertissement Risque Relié AUX Pièces MobilesAvertissement Risque DE Chute Avertissement Risque Dune Utilisation Dangereuse Cycle DE Service AccessoiresLexique SpécificationsEmplacement du compresseur dair Assemblage pour appareils à réservoirÉcrou Directives DE Mise À LA Terre RallongesProtection contre la surtension et protection du circuit Utilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Utilisation de lappareil Arrêt de lappareilAvant le démarrage Avant chaque mise en marcheEntretien Mise en marcheResponsabilités du client Vérification de la soupape de sûretéRemplacement ou nettoyage de la soupape de retenue Entertien ET RéglagesRemplacement du régulateur RangementLeau dans le réservoir dair peut condenser. Si le Dépannage SerrerPeut éclater ou exploser Considérée normale Fusible sauté ou coupe-circuit Diagramme DU Compresseur À AIR Liste DES Piêces Clé No Nº de Pièce DescriptionDiagramme DU Pompe Kit disponibles Non montréAN Garantie limitée sur tous les accessoires Garantie Limitée