Campbell Hausfeld NB0040 operating instructions Description, General Safety Information

Page 1
110 psi

Operating Instructions

Model NB0040

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop- erty damage! Retain instructions for future reference.

Brad Nailer

TM

BUILT TO LAST

Table Of Contents

 

 

General Safety

. .

1-2

Specifications

. .

. .2

Operating the Nailer

3-5

Contact Trip Safety Mechanism

. 3

Fasteners

. .

. .5

Troubleshooting

. 5

Warranty

. 6

Description

 

 

This nailer is designed for decorative trim,

molding, window casings, furniture trim

and picture frame assembly. Features

include: convenient side loading maga-

zine which holds up to 100 nails, an

 

adjustable exhaust with muffler, a con-

tact trip trigger, and a quick clear nose.

General Safety Information

This manual contains safety,

 

 

operational and maintenance

 

 

information.

 

 

Read this manual and under-

 

 

 

MANUAL

stand all safety warnings and

 

 

instructions before operating

 

 

the nailer. Contact your Campbell

 

 

Hausfeld representative if you have any

questions.

 

 

OPERATOR’S RESPONSIBILITY:

 

 

Before operating the nailer, read and

understand all safety warnings and

 

labels. Follow the operating instructions

outlined in this manual.

 

 

EMPLOYER’S RESPONSIBILITY:

 

 

Distribute this instruction manual to all

users before allowing use of the nailer.

Ensure all operators read, understand

and follow all safety warnings, labels and

instructions outlined in this

 

 

manual.

 

 

Danger indicates an imminently haz-

ardous situation which, if not avoided, WILL result in death or serious injury.

Do not use any type of flammable

gases or oxygen as

 

a power source for

O

the nailer. Use fil-

CO2

tered, lubricated,

 

regulated com-

 

pressed air only.

 

Use of a compressed gas instead of compressed air may cause the nailer to explode which will cause death or serious personal injury.

Do not exceed maxi- mum operating pres-

sure of the nailer (110 psi). The nailer will

not function properly.

Do not use a com-MAX. pressed air source capable of more than 200 PSI. The nailer could explode which will cause death or serious personal injury.

Never use gasoline

or other flammable liquids to clean the nailer. Never use the

nailer in the presence

of flammable liquids or gases. Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury.

Always remain in

a firmly balanced position when using or handling the nail-

er.

Do not modify or disable the

Work Contact

Element (WCE).

Do not tie or tape the WCE or trigger in a depressed posi-

tion. Death or

serious personal injury could result.

Model NB0040

Locate model and serial number on tool magazine and cap and record below:

Model No. ________________________

Serial No. _________________________

Retain these numbers for

future reference.

Do not touch the trigger

unless driving nails. Never

attach air line to nailer or carry nailer while touching

the trigger.

The tool could eject a fastener which will result in death or serious per- sonal injury.

Warning indicates a potentially haz- ardous situation which, if not avoided,

COULD result in death or serious injury.

Always disconnect

nailer from air line before clearing jams, adjusting or servicing

the nailer, relocating the nailer, or when the nailer is not in use. Always reconnect the air line BEFORE loading any fasteners. The nailer could eject a fastener causing death or serious personal injury.

Campbell Hausfeld Nailers meet or exceed Industries’ Standards as set forth by the American National Standard Institute/International Staple, Nail and Tool Association in ANSI/ISANTA SNT-101-1993.

© 1999 Campbell Hausfeld

For parts, product & service information

IN265500AV 5/99

visit www.campbellhausfeld.com

Image 1
Contents Description General Safety InformationHeight 91⁄2 Maximum Pressure 110 psi Length 91⁄2Pressure Range 70-110 psi Operating The Nailer Model NB0040Assembly Procedure For Seals Fasteners and Replacement PartsNailer Repair Fasteners Troubleshooting GuideInterchange Information Responsibilities of Purchaser Under this Warranty What is not Covered Under this WarrantyGénéralités Sur La Sécurité Table Des MatièresResponsabilité DE L’UTILISATEUR Gamme DE Pression 483 758 bar Modèle NB0040Modèle NB0040 Branchement RecommandéUtilisation de la Cloueuse GraissageTionner Doit PASDoit Tionner Charge MENT/DÉCHARGEMENT DE LA CloueuseAttaches et Réparation de la Cloueuse Support TechniqueMéthode d’assemblage pour les joints d’étanchéité Symptôme Causes Possibles Mesures Correctives AttachesResponsabilités DE L’ACHETEUR AUX Termes DE Cette Garantie LA Présente Garantie NE Couvre PASDescripción ÍndiceInformaciones Generales de Seguridad Responsabilidad DEL OperadorComponentes y Especificaciones de la Clavadora Modelo NB0040Entrada DE Aire 6,4mm 1/4 NPT Presion MAX ,58 barLubricacion Cómo Usar la ClavadoraConexion Recomendada Mecanismo DE Seguridad Para EL Disparador DE ContactoPara Cargar Y Descargar LA Clavadora Debe FUNPara Ajustar LA Penetracion DE LOS Clavos Para Ajustar LA Direccion DEL Tubo DE EscapeClavos et Repuestos Servicio TécnicoPara reparar la clavadora Para colocarle los sellosInformación de intercambio ClavosGuía de Diagnóstico de Averías Responsabilidades DEL Comprador Bajo Esta Garantia LO QUE no Esta Cubierto POR Esta Garantia