| Maintenance |
|
|
6.0Specifications
Table 7 | Compressor Module Specifications | ||
|
| ||
General Information |
| ||
Inlet pressure range | Model specific - refer to application envelope | ||
Outlet pressure range | 70 to 275 psig (depends on | ||
Mechanical Description |
| ||
Module weight | Approximately 350 lb. (160kg) | ||
Suction connection | 1.0” NPT | ||
Discharge connection | 0.75” NPT | ||
Sound level |
| Approximately 72 dBA @ 1 m, 58 dBA @ 10 m | |
Vibration |
| 3 mil at 60 Hz | |
Minimum cold start ambient temperature 1,4 | Compressor | ||
Ambient operating temperature range 1,4 | 0 to 122°F | ||
Module dimensions | See Figure 4 on page 7 | ||
Materials of Construction |
| ||
Compressor - general | Cold rolled steel, aluminum, cast iron as required | ||
Compressor bearings | |||
Oil heat exchanger | Aluminum | ||
Oil/gas separator tank | Cold rolled steel | ||
Tubes/fittings/skid structure | Stainless/carbon steel | ||
Lubrication |
|
| |
Oil type |
| Synthetic, 15 or 32 weight, PAO (special | |
System oil capacity, oz. (ml) | 170 fluid ounces (5.0 liters) | ||
Projected oil consumption 2 | Approximately 40 oz. (0.9 l) / 8,000 hours at 0.25 psig suction (<5 ppm) | ||
System Electrical (Standard) |
| ||
Minimum VFD ambient startup temperature3,4 | +14°F | ||
Power supply to inverter | 380 to 480VAC (50/60 Hz) | ||
• Voltage range |
| ||
• Input frequency range |
| ||
|
| ||
Overpressure detection (outlet) | 215 psig open | ||
Underpressure detection (inlet) | 0.75 psig open (low pressure system) / 2" water column | ||
Oil overtemperature detection | 240°F (110°C) open (280°F for SZV) model specific | ||
Fault output to customer | Packager to establish | ||
Run input from customer | Dry contact | ||
Gas Medium |
| ||
Natural gas |
|
| |
H | S maximum content 5 | 25 ppm | |
2 |
|
|
|
Moisture content 5 | 100% saturated, no free liquids | ||
Inlet temperature 5 |
1.If the Compressors are started at temperatures above the listed minimums and continue to run, the minimum operating temperature is 20°F
2.Based on sweet gas wellhead gas. Results may vary due to gas quality and site conditions.
3.Do not apply power to the VFD if ambient temperature is below this level.
4.If power is continuously supplied to the VFD when the Compressor is off, the minimum starting temperature is
5.Consult factory for more details and applications guidelines.
24 |