Emerson SZO22, SZV22 manual Cleaning the Inlet Screen, Servicing the Scavenge Line Orifice

Page 27

Single-Compressor Module

Maintenance

4.4Cleaning the Inlet Screen

The 30-mesh screen in the inlet block must remain unobstructed for optimal flow rate. If the flow rate is lower than expected even when the Compressor is running properly, this screen may be obstructed.

Figure 14 Gas Inlet Block and Screen

To inspect and clean the inlet screen:

1.Turn off and isolate the Compressor from all power sources.

2.Turn off the gas supply.

3.Vent the system to 0 psig.

4.Remove the SAE plug on the side of the inlet block.

5.Remove the screen.

6.Inspect the screen and inside of the block. Clean or replace if necessary.

7.Replace SAE nut.

8.Return the Compressor Package to service.

9.Check for leaks at all fittings that have been disturbed.

4.5Servicing the Scavenge Line Orifice

The scavenge line orifice in the oil separator block must remain clear of obstruction. If this orifice is restricted, the secondstage oil separator can become saturated, increasing oil consumption.

Note: image shown is 90 degree orifice. Procedure is the same for straight orifice.

Figure 15 Scavenge Line Orifice

Orifice

To inspect and clean the orifice:

1.Turn off and isolate the Compressor from all power sources.

2.Turn off the gas supply.

3.Vent the system to 0 psig.

4.Disconnect the tube and remove the fitting.

5.Inspect the screen. Clean or replace the fitting assembly if necessary.

6.Replace the fitting and reconnect the tube. Tighten the swage nut hand tight plus 1/4 turn.

7.Return the Compressor Package to service.

8.Check for leaks at all fittings that have been disturbed.

21

2008SSD-34 (5/11)

Image 27
Contents Copeland Scroll Compressor Module Page Table of Contents Table of Contents Figures Compressor Module Nomenclature Important Safety Information Safety Symbols Used in This Manual Safety Alert SymbolIntroduction Compressor ModuleCompressor Package CompressorRequired Component-Inlet Gas Scrubber Installation GuidelinesGeneral Installation Guidelines Inlet and Discharge PressuresAmbient Temperature Range Compressor Module Dimensions, in. mm Installation Clearance and DimensionsProcess and Instrumentation Diagrams P&IDs General Considerations SwitchesSwitchStatus Electrical ControlsBrushless DC Fan Oil Cooler Fan ControlSingle-Compressor Module Installation Motor Control Code Description Typical Compressor Module power supply requirementsCompressor Power data based on 480VAC Variable Speed Electrical RequirementsControl Circuit Terminations Control Wiring Terminations WiringPre-Startup Checklist Initial Startup Compressor ModuleVariable Frequency Drive VFD Terminations During Initial OPERATION, Perform These Checks Post-Startup ChecklistRoutine Maintenance MaintenanceMaintenance summary Maintenance Tools Maintenance ToolsPossible Cause Oil ServiceSymptoms High Oil CarryoverSingle-Compressor Module Maintenance Servicing the Scavenge Line Orifice Cleaning the Inlet ScreenChanging the Second-Stage Separator Element Troubleshooting GuideTroubleshooting VFD fault codes and descriptionsPlatform troubleshooting guidelines Platform Symptoms DiagnosisSpecifications Compressor Module Specifications Components and Hazard Statement Appendix A - Material Data Safety SheetSupplier Emergency Number 989 Product Name and InformationHealth Hazard Data Spill or Leak ProceduresFire and Explosion Hazards Reactivity DataPage EmersonClimate.com