Emerson SZO22, SZV22 manual Figures

Page 5

Single-Compressor Module

TABLE OF CONTENTS

 

FIGURES

 

Figure 1

Compressor Module Components

3

Figure 2

Copeland Scroll® Compressor Cross Section

4

Figure 3

Typical Compressor Package

4

Figure 4

Compressor Module Dimensions, in. (mm)

7

Figure 5

Compressor Module Gas and Oil Flow Diagram and Safety Shutdowns

8

Figure 6

Brushless DC Fan

10

Figure 7

Basic Fan Control System

10

Figure 8

Optional Customer-Installed High Temperature Fan Control System

11

Figure 9

Oil Cooling and Thermal Valve

11

Figure 10

Motor Control

12

Figure 11

Typical Compressor Module Electrical Requirements

13

Figure 12

Control Circuit Terminations

14

Figure 13

Maintenance Tools

18

Figure 14

Gas Inlet Block and Screen

21

Figure 15

Scavenge Line Orifice

21

 

 

 

TABLES

 

Table 1

Inlet and discharge pressure limits

5

Table 2

Typical Compressor Module power supply requirements

13

Table 3

Maintenance summary

17

Table 4

Troubleshooting

22

Table 5

VFD fault codes and descriptions

22

Table 6

Platform troubleshooting guidelines

23

Table 7

Compressor Module specifications

24

iii

2008SSD-34 (5/11)

Image 5
Contents Copeland Scroll Compressor Module Page Table of Contents Table of Contents Figures Compressor Module Nomenclature Important Safety Information Safety Symbols Used in This Manual Safety Alert SymbolIntroduction Compressor ModuleCompressor Package CompressorGeneral Installation Guidelines Installation GuidelinesInlet and Discharge Pressures Required Component-Inlet Gas ScrubberAmbient Temperature Range Compressor Module Dimensions, in. mm Installation Clearance and DimensionsProcess and Instrumentation Diagrams P&IDs SwitchStatus SwitchesElectrical Controls General ConsiderationsBrushless DC Fan Oil Cooler Fan ControlSingle-Compressor Module Installation Motor Control Compressor Power data based on 480VAC Variable Speed Typical Compressor Module power supply requirementsElectrical Requirements Code DescriptionControl Circuit Terminations Control Wiring Terminations WiringVariable Frequency Drive VFD Terminations Pre-Startup ChecklistInitial Startup Compressor Module During Initial OPERATION, Perform These Checks Post-Startup ChecklistMaintenance summary Routine MaintenanceMaintenance Maintenance Tools Maintenance ToolsSymptoms Oil ServiceHigh Oil Carryover Possible CauseSingle-Compressor Module Maintenance Servicing the Scavenge Line Orifice Cleaning the Inlet ScreenTroubleshooting Troubleshooting GuideVFD fault codes and descriptions Changing the Second-Stage Separator ElementPlatform troubleshooting guidelines Platform Symptoms DiagnosisSpecifications Compressor Module Specifications Supplier Appendix A - Material Data Safety SheetEmergency Number 989 Product Name and Information Components and Hazard StatementFire and Explosion Hazards Spill or Leak ProceduresReactivity Data Health Hazard DataPage EmersonClimate.com