Emerson CMF200A UL and CSA ambient temperature limits, Sensor models Electronics

Page 10

Determining a Location

Figure 6 High-temperature and extreme high-temperature ELITE sensor ambient and process temperature limits

(°C)

176 (80)

 

 

 

 

 

 

 

662

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(350)

 

 

 

°F

140 (60)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in

 

 

 

 

 

 

 

 

 

 

 

 

transmitter

104 (40)

 

 

 

 

 

 

 

 

 

 

 

68 (20)

 

 

High-temp. models

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

processor

32 (0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extreme high-temp. models

 

 

 

 

 

 

 

–4 (–20)

 

 

 

 

 

 

 

 

 

 

 

core

–40 (–40)

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature

–76 (–60)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mount transmitter remotely; use junction box

 

 

 

 

–112 (–80)

 

 

 

 

 

 

 

 

 

 

 

Ambient

–148 (–100)

 

 

 

 

 

 

 

 

 

 

 

–58 (–50)

32 (0)

122 (50)

212 (100)

302 (150)

392 (200)

482 (250)

572 (300)

662 (350)

752 (400)

800 (427)

842 (450)

Maximum process temperature in °F (°C)

Notes:

1.When ambient temperature is below –40 °F (–40 °C), a core processor or Model 2400S transmitter must be heated to bring its local ambient temperature to between –40 °F (–40 °C) and +140 °F (+60 °C). Long-term storage of electronics at ambient temperatures below –40 °F (–40 °C) is not recommended.

2.Temperature limits may be further restricted by hazardous area approvals.

Hazardous area approvals may impose additional limits on ambient and process temperature. For the ATEX “T” rating, refer to the ATEX documentation shipped with the sensor or available on the Micro Motion web site at www.micromotion.com. IECEx and NEPSI approvals also use the ATEX “T” rating. UL and CSA ambient temperature limits are listed in Table 1.

Table 1 UL and CSA ambient temperature limits

 

Sensor models

Electronics

°F

°C

UL

All models

Junction box

+104 maximum

+40 maximum

 

 

Core processor

–40 to +104

–40 to +40

 

 

 

 

 

CSA

All models

Junction box

+140 maximum

+60 maximum

 

 

Core processor

–40 to +140

–40 to +60

 

All models except CMF400

2400S transmitter

–40 to +140

–40 to +60

 

CMF400

2400S transmitter

–58 to +140

–50 to +60

 

 

 

 

 

8

Micro Motion® ELITE® Sensors

Image 10
Contents Micro Motion Elite Sensors Page Troubleshooting Customer serviceBefore You Begin European installations Specifications DefinitionsInstallation options CMF025, CMF050, or CMF100 Elite sensor with core processor Elite sensor with junction box Full flow tubes Hazardous area installationsDetermining a Location Environmental limits113 UL and CSA ambient temperature limits Sensor models ElectronicsPipe run Maximum wiring distancesMaximum cable lengths ValvesFlow direction arrow Orienting the SensorRecommended sensor orientations Vertical pipelineMounting the Sensor Mounting an Elite sensorInstalling extended mount electronics Feedthrough, plastic cap, and clamping ringMounting the temperature extender onto the sensor Installing wafer-style sensors Wafer-style assembly Wiring Core processor to a 4-wire remote transmitterWrapping the shield drain wires Applying the heat shrink Connecting the wires at the core processor Pressure Ratings GroundingElite pressure ratings Purge Fittings Case purging procedureRemoving a purge plug Rupture Disks Time required to purge Elite sensor casesNew and unused equipment Return PolicyUsed equipment 20002158