Emerson CMF200A Orienting the Sensor, Recommended sensor orientations, Flow direction arrow

Page 12

Orienting the Sensor

Step 2 Orienting the Sensor

The sensor will function properly in any orientation if the sensor tubes remain filled with process fluid. Micro Motion recommends orienting ELITE sensors as shown in Table 3.

Table 3 Recommended sensor orientations

Sensor model

Application

Recommended orientation

CMF010

All applications

Tubes flat

 

 

Horizontal pipeline

CMF025, CMF050,

Liquids

Tubes down

and CMF100

 

Horizontal pipeline

 

Gases and slurries

Tubes up

 

 

Horizontal pipeline

CMF200, CMF300,

Liquids

Tubes down

CMF400, and

 

Horizontal pipeline

CMFHC3

 

 

 

Gases

Tubes up

 

 

Horizontal pipeline

 

Slurries

Flag mount

 

 

Vertical pipeline

Flow direction arrow

The sensor has a flow direction arrow (see Figures 1–4) to help you configure the transmitter for flow direction. If possible, install the sensor so that the flow direction arrow matches actual process flow.

Vertical pipeline

If the sensor is installed in a vertical pipeline, liquids and slurries should flow upward through the sensor. Gases may flow upward or downward.

10

Micro Motion® ELITE® Sensors

Image 12
Contents Micro Motion Elite Sensors Page Customer service TroubleshootingBefore You Begin Specifications Definitions European installationsInstallation options CMF025, CMF050, or CMF100 Elite sensor with core processor Elite sensor with junction box Hazardous area installations Determining a LocationFull flow tubes Environmental limits113 UL and CSA ambient temperature limits Sensor models ElectronicsMaximum wiring distances Maximum cable lengthsPipe run ValvesOrienting the Sensor Recommended sensor orientationsFlow direction arrow Vertical pipelineMounting the Sensor Mounting an Elite sensorInstalling extended mount electronics Feedthrough, plastic cap, and clamping ringMounting the temperature extender onto the sensor Installing wafer-style sensors Wafer-style assembly Wiring Core processor to a 4-wire remote transmitterWrapping the shield drain wires Applying the heat shrink Connecting the wires at the core processor Grounding Pressure RatingsElite pressure ratings Case purging procedure Purge FittingsRemoving a purge plug Rupture Disks Time required to purge Elite sensor casesReturn Policy New and unused equipmentUsed equipment 20002158