Agilent Technologies E9300 manual General Information, Power Meter Requirements

Page 13

General Information

General Information

Welcome to the HP E-series E9300 power sensors Operating and Service Guide! This guide contains information about the initial inspection, operation, specifications and repair of the HP E-series E9300 power sensors. Use this guide as a supplement to the Agilent EPM series power meters User’s Guides. It is 3-hole drilled to allow you to retain it in the power meter’s binder.

All power meter functions are detailed in the Agilent EPM series power meters User’s Guide and Programming Guide, however, this guide contains information specific to the operation of Agilent E-series E9300 power sensor.

Power Meter Requirements

The HP E-series E9300 power sensors are NOT compatible with the earlier HP 430-Series, HP E1416A, or HP 70100A power meters. They are compatible ONLY with the Agilent EPM series power meters. Also, not all Agilent EPM series power meters are immediately compatible - your power meter must use firmware and Digital Signal Processing (DSP) code from a specific release onwards. see Checking Power Meter Firmware and DSP Revision on page 16 tells you how to check your power meter and have it upgraded if required.

13

Image 13
Contents Operating and Service Guide Copyright 1999 Agilent Technologies Legal Information WarrantyCertification Exclusive Remedies Limitation of WarrantySound Emission General Safety InformationPower Meter Front Panel Operation SafetyConventions Sensors Covered by Manual DocumentationRelated Publications Documentation Table of Contents Standing Wave Ratio SWR and Reflection Coefficient Rho Per Introduction Typical HP E-series E9300 power sensors General Information Power Meter RequirementsSimplified Block Diagram of Diode Pair/Attenuator/Diode Pair Agilent E-Series E9300 Power Sensors in DetailGeneral Information Getting Started Checking Power Meter Firmware and DSP RevisionInitial Inspection Interconnections and Calibration Specifications Making Measurements What You’ll Find This Chapter Auto-averaging Settings Power Meter Configuration ChangesSpread Spectrum Signal Measuring Spread Spectrum and Multitone SignalsCdma IS-95A 9Ch Fwd Cdma Signal Measurements90 % Frequency GHz Typical Lower Range Calibration Factor Multitone Signal MeasurementsPower Meter and Sensor Operation Measuring Tdma SignalsAchieving Stable Results with Tdma Signals Input Settings , More Achieving Stable Results with GSM SignalsElectromagnetic Compatibility EMC Measurements Measurement Accuracy and Speed Setting the RangeAccuracy Measurement ConsiderationsSummary Speed and AveragingSpecifications and Characteristics Introduction Sensor Low Power Path High Power PathConnector Type E9300/1/4/A Power Sensor SpecificationsMaximum SWR 0C to +55C Maximum DC Voltage Maximum Power± 2.5% Power LinearityTypical Power Linearity at 25C, after zero Additional Power Zero Set Zero Drift Measurement Noise Switching PointTime E4418B E4419B Settling TimeCalibration Factor and Reflection Coefficient X2 ModeCal Factor Uncertainty General Frequency Range E9300/1B and H Power Sensor SpecificationsE9300B Typical SWR 25C ± 10C E9300H Typical SWR 10 MHz to 18 GHz 25C ± 10C Maximum Power Sensor To 35 C To 55 C GHz E9300/1B To 0 dBm To 10 dBm 10 to 20 dBm 20 to 26 dBm For larger changes refer to the following table E9300/1H DBm to 0 dBm +44 +30 dBm E9300/1B Conditions Zero Set Zero Drift2 Measurement Settling Time Typical Cal Factor Uncertainty Low Power Path Cal Factor Uncertainty High Power Path Storage and Shipment Environment ReferencesE9300/1B and H Power Sensor Specifications Service Connector Cleaning CleaningFrequency System Rho Actual Maximum Uncertainty Measurement Performance TestPerformance Test Is the illustrated parts breakdown IPB that identifies all Replaceable PartsIllustrated Parts Break down Reference Agilent Part Qty Description Designation Number LABEL, ID E9301B Principles of Operation ServiceDisassembly Procedure TroubleshootingRepair of Defective Sensor Removing Power Sensor Shell Reassembly ProcedureAsia Pacific Sales and Service OfficesEurope