Agilent Technologies E9300 manual Sales and Service Offices, Asia Pacific

Page 70

Sales and Service Offices

Sales and Service Offices

For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site:http://www.agilent.com

You can also contact one of the following centers and ask for a test and measurement sales representative.

Asia Pacific:

Agilent Technologies

19/F, Cityplaza One, 1111 King’s Road, Taikoo Shing, Hong Kong, SAR

(tel) (852) 2599 7889 (fax) (852) 2506 9233

Japan:

Agilent Technologies Japan Ltd. Measurement Assistance Center 9-1, Takakura-Cho, Hachioji-Shi Yokyo, 192-8510

(tel) (81) 426 56 7832 (fax) (81) 426 56 7840

Australia/New Zealand:

Agilent Technologies Australia Pty Ltd 347 Burwood Highway

Forest Hill, Victoria 3131 (tel) 1-800 629 485 (Australia) (fax) (61 3) 9272 0749

(tel) 0 800 738 378 (New Zealand) (fax) (64 4) 802 6881

Canada:

Agilent Technologies Canada Inc. 5150 Spectrum Way, Mississauga, Ontario

L4W 5G1

(tel) 1 877 894 4414

70

Image 70
Contents Operating and Service Guide Copyright 1999 Agilent Technologies Legal Information WarrantyCertification Limitation of Warranty Exclusive RemediesGeneral Safety Information Sound EmissionPower Meter Front Panel Operation SafetyConventions Sensors Covered by Manual DocumentationRelated Publications Documentation Table of Contents Standing Wave Ratio SWR and Reflection Coefficient Rho Per Introduction Typical HP E-series E9300 power sensors Power Meter Requirements General InformationAgilent E-Series E9300 Power Sensors in Detail Simplified Block Diagram of Diode Pair/Attenuator/Diode PairGeneral Information Getting Started Checking Power Meter Firmware and DSP RevisionInitial Inspection Interconnections and Calibration Specifications Making Measurements What You’ll Find This Chapter Power Meter Configuration Changes Auto-averaging SettingsMeasuring Spread Spectrum and Multitone Signals Spread Spectrum SignalCdma Signal Measurements Cdma IS-95A 9Ch FwdMultitone Signal Measurements 90 % Frequency GHz Typical Lower Range Calibration FactorPower Meter and Sensor Operation Measuring Tdma SignalsAchieving Stable Results with Tdma Signals Achieving Stable Results with GSM Signals Input Settings , MoreElectromagnetic Compatibility EMC Measurements Setting the Range Measurement Accuracy and SpeedMeasurement Considerations AccuracySpeed and Averaging SummarySpecifications and Characteristics Sensor Low Power Path High Power Path IntroductionConnector Type E9300/1/4/A Power Sensor SpecificationsMaximum SWR 0C to +55C Maximum Power Maximum DC VoltagePower Linearity ± 2.5%Typical Power Linearity at 25C, after zero Additional Power Switching Point Zero Set Zero Drift Measurement NoiseSettling Time Time E4418B E4419BX2 Mode Calibration Factor and Reflection CoefficientCal Factor Uncertainty General E9300/1B and H Power Sensor Specifications Frequency RangeE9300B Typical SWR 25C ± 10C E9300H Typical SWR 10 MHz to 18 GHz 25C ± 10C Maximum Power Sensor To 35 C To 55 C GHz E9300/1B To 0 dBm To 10 dBm 10 to 20 dBm 20 to 26 dBm For larger changes refer to the following table E9300/1H DBm to 0 dBm +44 +30 dBm E9300/1B Conditions Zero Set Zero Drift2 Measurement Settling Time Typical Cal Factor Uncertainty Low Power Path Cal Factor Uncertainty High Power Path References Storage and Shipment EnvironmentE9300/1B and H Power Sensor Specifications Service Cleaning Connector CleaningPerformance Test Frequency System Rho Actual Maximum Uncertainty MeasurementPerformance Test Replaceable Parts Is the illustrated parts breakdown IPB that identifies allIllustrated Parts Break down Reference Agilent Part Qty Description Designation Number LABEL, ID E9301B Service Principles of OperationDisassembly Procedure TroubleshootingRepair of Defective Sensor Reassembly Procedure Removing Power Sensor ShellSales and Service Offices Asia PacificEurope