Agilent Technologies
E9300
manual
Documentation
Troubleshooting
Specifications
Spread Spectrum Signal
Warranty
Connector Type
Reassembly Procedure
Auto-averaging Settings
Cleaning
Safety
Power Meter Requirements
Page 8
Documentation
8
Page 7
Page 9
Image 8
Page 7
Page 9
Contents
Operating and Service Guide
Copyright 1999 Agilent Technologies
Certification
Warranty
Legal Information
Limitation of Warranty
Exclusive Remedies
General Safety Information
Sound Emission
Conventions
Safety
Power Meter Front Panel Operation
Related Publications
Documentation
Sensors Covered by Manual
Documentation
Table of Contents
Standing Wave Ratio SWR and Reflection Coefficient Rho Per
Introduction
Typical HP E-series E9300 power sensors
Power Meter Requirements
General Information
Agilent E-Series E9300 Power Sensors in Detail
Simplified Block Diagram of Diode Pair/Attenuator/Diode Pair
General Information
Initial Inspection
Checking Power Meter Firmware and DSP Revision
Getting Started
Interconnections and Calibration
Specifications
Making Measurements
What You’ll Find This Chapter
Power Meter Configuration Changes
Auto-averaging Settings
Measuring Spread Spectrum and Multitone Signals
Spread Spectrum Signal
Cdma Signal Measurements
Cdma IS-95A 9Ch Fwd
Multitone Signal Measurements
90 % Frequency GHz Typical Lower Range Calibration Factor
Achieving Stable Results with Tdma Signals
Measuring Tdma Signals
Power Meter and Sensor Operation
Achieving Stable Results with GSM Signals
Input Settings , More
Electromagnetic Compatibility EMC Measurements
Setting the Range
Measurement Accuracy and Speed
Measurement Considerations
Accuracy
Speed and Averaging
Summary
Specifications and Characteristics
Sensor Low Power Path High Power Path
Introduction
Maximum SWR
E9300/1/4/A Power Sensor Specifications
Connector Type
0C to +55C
Maximum Power
Maximum DC Voltage
Power Linearity
± 2.5%
Typical Power Linearity at 25C, after zero
Additional Power
Switching Point
Zero Set Zero Drift Measurement Noise
Settling Time
Time E4418B E4419B
X2 Mode
Calibration Factor and Reflection Coefficient
Cal Factor Uncertainty
General
E9300/1B and H Power Sensor Specifications
Frequency Range
E9300B Typical SWR 25C ± 10C
E9300H Typical SWR 10 MHz to 18 GHz 25C ± 10C
Maximum Power Sensor To 35 C To 55 C GHz
E9300/1B To 0 dBm To 10 dBm 10 to 20 dBm 20 to 26 dBm
For larger changes refer to the following table
E9300/1H DBm to 0 dBm
+44 +30 dBm
E9300/1B Conditions Zero Set Zero Drift2 Measurement
Settling Time
Typical
Cal Factor Uncertainty Low Power Path
Cal Factor Uncertainty High Power Path
References
Storage and Shipment Environment
E9300/1B and H Power Sensor Specifications
Service
Cleaning
Connector Cleaning
Performance Test
Frequency System Rho Actual Maximum Uncertainty Measurement
Performance Test
Replaceable Parts
Is the illustrated parts breakdown IPB that identifies all
Illustrated Parts Break down
Reference Agilent Part Qty Description Designation Number
LABEL, ID E9301B
Service
Principles of Operation
Repair of Defective Sensor
Troubleshooting
Disassembly Procedure
Reassembly Procedure
Removing Power Sensor Shell
Sales and Service Offices
Asia Pacific
Europe