General Safety Information

 

Conventions

 

The following text and format conventions are used to highlight items of safety

 

and the operation of the associated power meter.

 

Safety

 

This guide uses cautions and warnings to denote hazards.

 

 

Caution

Caution denotes a hazard. It calls attention to a procedure that, if not

 

correctly performed or adhered to, would result in damage to or

 

destruction of the instrument. Do not proceed beyond a caution sign

 

until the indicated conditions are fully understood and met.

 

 

 

 

WARNING

Warning denotes a hazard. It calls attention to a procedure

 

which, if not correctly performed or adhered to, could result in

 

injury or loss of life. Do not proceed beyond a warning note

 

until the indicated conditions are fully understood and met.

 

 

 

Power Meter Front Panel Operation

 

This guide uses the following symbols to denote power meter front panel keys

 

and display legends.

)URQW￿3DQHO￿.H\

6RIWNH\￿/DEHO

Display Text

A function name in a keycap symbol indicates the use of a key physically located on the power meter’s front panel.

A function name in display-font indicates the use of a key down the right side of the power meter’s display adjacent to the displayed text

Text shown in this font indicates message text displayed by the power meter.

6

Image 6
Contents Operating and Service Guide Copyright 1999 Agilent Technologies Warranty Legal InformationCertification Limitation of Warranty Exclusive RemediesGeneral Safety Information Sound EmissionSafety Power Meter Front Panel OperationConventions Documentation Sensors Covered by ManualRelated Publications Documentation Table of Contents Standing Wave Ratio SWR and Reflection Coefficient Rho Per Introduction Typical HP E-series E9300 power sensors Power Meter Requirements General InformationAgilent E-Series E9300 Power Sensors in Detail Simplified Block Diagram of Diode Pair/Attenuator/Diode PairGeneral Information Checking Power Meter Firmware and DSP Revision Getting StartedInitial Inspection Interconnections and Calibration Specifications Making Measurements What You’ll Find This Chapter Power Meter Configuration Changes Auto-averaging SettingsMeasuring Spread Spectrum and Multitone Signals Spread Spectrum SignalCdma Signal Measurements Cdma IS-95A 9Ch FwdMultitone Signal Measurements 90 % Frequency GHz Typical Lower Range Calibration FactorMeasuring Tdma Signals Power Meter and Sensor OperationAchieving Stable Results with Tdma Signals Achieving Stable Results with GSM Signals Input Settings , MoreElectromagnetic Compatibility EMC Measurements Setting the Range Measurement Accuracy and SpeedMeasurement Considerations AccuracySpeed and Averaging SummarySpecifications and Characteristics Sensor Low Power Path High Power Path IntroductionE9300/1/4/A Power Sensor Specifications Connector TypeMaximum SWR 0C to +55C Maximum Power Maximum DC VoltagePower Linearity ± 2.5%Typical Power Linearity at 25C, after zero Additional Power Switching Point Zero Set Zero Drift Measurement NoiseSettling Time Time E4418B E4419BX2 Mode Calibration Factor and Reflection CoefficientCal Factor Uncertainty General E9300/1B and H Power Sensor Specifications Frequency RangeE9300B Typical SWR 25C ± 10C E9300H Typical SWR 10 MHz to 18 GHz 25C ± 10C Maximum Power Sensor To 35 C To 55 C GHz E9300/1B To 0 dBm To 10 dBm 10 to 20 dBm 20 to 26 dBm For larger changes refer to the following table E9300/1H DBm to 0 dBm +44 +30 dBm E9300/1B Conditions Zero Set Zero Drift2 Measurement Settling Time Typical Cal Factor Uncertainty Low Power Path Cal Factor Uncertainty High Power Path References Storage and Shipment EnvironmentE9300/1B and H Power Sensor Specifications Service Cleaning Connector CleaningPerformance Test Frequency System Rho Actual Maximum Uncertainty MeasurementPerformance Test Replaceable Parts Is the illustrated parts breakdown IPB that identifies allIllustrated Parts Break down Reference Agilent Part Qty Description Designation Number LABEL, ID E9301B Service Principles of OperationTroubleshooting Disassembly ProcedureRepair of Defective Sensor Reassembly Procedure Removing Power Sensor ShellSales and Service Offices Asia PacificEurope