Agilent Technologies E9300 manual General Safety Information, Sound Emission

Page 5

General Safety Information

 

General Safety Information

 

The following general safety precautions must be observed during all phases

 

of operation, service and repair of this sensor. Failure to comply with these

 

precautions or specific warnings elsewhere in this manual violates safety

 

standards of design manufacture and intended use of the sensor. Agilent

 

Technologies assumes no liability for the customer’s failure to comply with

 

these requirements.

 

The Instruction Documentation Symbol. The product is marked with this

 

symbol when it is necessary for the user to refer to the instructions in the

 

supplied documentation.

 

 

WARNING

BEFORE CONNECTING THE POWER SENSOR TO OTHER

 

INSTRUMENTS ensure that all instruments are connected to

 

the protective (earth) ground. Any interruption of the

 

protective earth grounding will cause a potential shock hazard

 

that could result in personal injury.

 

 

 

Sound Emission

 

Herstellerbescheinigung

 

Diese Information steht im Zusammenhang mit den Anforderungen der

 

Maschinenlarminformationsverordnung vom 18 Januar 1991.

 

• Sound Pressure LpA < 70 dB.

 

Am Arbeitsplatz.

 

Normaler Betrieb.

 

• Nach DIN 45635 T. 19 (Typprufung).

 

Manufacturers Declaration

 

This statement is provided to comply with the requirements of the German

 

Sound DIN 45635 T. 19 (Typprufung).

 

• Sound Pressure LpA < 70 dB.

 

At operator position.

 

Normal operation.

• According to ISO 7779 (Type Test).

5

Image 5
Contents Operating and Service Guide Copyright 1999 Agilent Technologies Certification WarrantyLegal Information Exclusive Remedies Limitation of WarrantySound Emission General Safety InformationConventions SafetyPower Meter Front Panel Operation Related Publications DocumentationSensors Covered by Manual Documentation Table of Contents Standing Wave Ratio SWR and Reflection Coefficient Rho Per Introduction Typical HP E-series E9300 power sensors General Information Power Meter RequirementsSimplified Block Diagram of Diode Pair/Attenuator/Diode Pair Agilent E-Series E9300 Power Sensors in DetailGeneral Information Initial Inspection Checking Power Meter Firmware and DSP RevisionGetting Started Interconnections and Calibration Specifications Making Measurements What You’ll Find This Chapter Auto-averaging Settings Power Meter Configuration ChangesSpread Spectrum Signal Measuring Spread Spectrum and Multitone SignalsCdma IS-95A 9Ch Fwd Cdma Signal Measurements90 % Frequency GHz Typical Lower Range Calibration Factor Multitone Signal MeasurementsAchieving Stable Results with Tdma Signals Measuring Tdma SignalsPower Meter and Sensor Operation Input Settings , More Achieving Stable Results with GSM SignalsElectromagnetic Compatibility EMC Measurements Measurement Accuracy and Speed Setting the RangeAccuracy Measurement ConsiderationsSummary Speed and AveragingSpecifications and Characteristics Introduction Sensor Low Power Path High Power PathMaximum SWR E9300/1/4/A Power Sensor SpecificationsConnector Type 0C to +55C Maximum DC Voltage Maximum Power± 2.5% Power LinearityTypical Power Linearity at 25C, after zero Additional Power Zero Set Zero Drift Measurement Noise Switching PointTime E4418B E4419B Settling TimeCalibration Factor and Reflection Coefficient X2 ModeCal Factor Uncertainty General Frequency Range E9300/1B and H Power Sensor SpecificationsE9300B Typical SWR 25C ± 10C E9300H Typical SWR 10 MHz to 18 GHz 25C ± 10C Maximum Power Sensor To 35 C To 55 C GHz E9300/1B To 0 dBm To 10 dBm 10 to 20 dBm 20 to 26 dBm For larger changes refer to the following table E9300/1H DBm to 0 dBm +44 +30 dBm E9300/1B Conditions Zero Set Zero Drift2 Measurement Settling Time Typical Cal Factor Uncertainty Low Power Path Cal Factor Uncertainty High Power Path Storage and Shipment Environment ReferencesE9300/1B and H Power Sensor Specifications Service Connector Cleaning CleaningFrequency System Rho Actual Maximum Uncertainty Measurement Performance TestPerformance Test Is the illustrated parts breakdown IPB that identifies all Replaceable PartsIllustrated Parts Break down Reference Agilent Part Qty Description Designation Number LABEL, ID E9301B Principles of Operation ServiceRepair of Defective Sensor TroubleshootingDisassembly Procedure Removing Power Sensor Shell Reassembly ProcedureAsia Pacific Sales and Service OfficesEurope