AEG PV 2000 operating instructions Inverter Status, Display information

Page 21

21

6. Inverter Status

Protect PV is designed to be user-friendly; therefore, the status of the Inverter can be easily understood by reading the information shown on the front panel display. All possible messages are shown in the following table.

Display information

Operating conditions

Message

Description

 

 

 

Normal Working Status

 

 

Power off

No display

PV inverter is totally

shutdown, VPV <=70V

 

 

Standby

STANDBY

90V< Input voltage < =100V

 

 

 

 

 

Input voltage range 100~150V

 

 

during start-up. After PV

Initialization & waiting

READY

voltage is higher than 100V,

 

 

inverter is waiting for feeding

 

 

to grid

 

 

When PV voltage> 150V,

Check grid

CHECKINGxxxs

inverter is checking feeding

 

 

conditions

 

 

Inverter is feeding power. After 10

Feeding grid, MPPT

GRID CONNECTED

seconds of this display, LED will show

 

 

wattage.

FLASH

FLASH

FLASH-firmware

 

 

 

Today energy

Etoday=xxx.xxkWh

Total energy to has been fed

to grid since today

 

 

Monitoring parameters

 

 

 

 

 

Instantaneous

Pac=xxx.xW

The real time output power in xxxx W

Output power

 

 

Accumulated energy

 

Total energy to has been fed

Etot=xxxxxxkWh

to grid since inverter was

information

 

installed

 

 

Grid voltage

Vac=xxx.xV

Grid voltage in xxx.x VAC

 

 

 

Grid frequency

Fac=xx.xHz

Grid frequency in xx.x Hz

 

 

 

Image 21
Contents DOC n 07/08/1002-2 Rev Protect pV 2000Contents BEFORe you start Risk of electric shock Safety instructionsTerms of warranty Limited warrantyWarranty claims procedure Exclusions Warranty extension Protect PV 2000 OverviewFeatures Before Installation Installation InstructionsMounting Protect PV to the wall Page Connecting to the grid AC utility Page Checking Connect to PV Panel DC inputSySTEm diagRam Operating Your PV-Inverter Modes of operationFront Panel Page Accuracy of the readinG Maximum power point trackinG mpptDisplay information Inverter StatusOvertemperature ERR Ground FaultERR Isolation ERR GridContrast Model PVSET Contrast LCD LockedCOmmuNiCaTiONS Page Display Trouble shootingLow DC Bus Specifications ModellDC Input Typical Efficiency charts vs. Load Regulation & Certificates Incident FormCompliance & Standards Page Operating Instructions