-11= TROUBLESHOOTING
1)Remove control panel and disconnect couplers on wiring.
2)Measuretheresistancebetween terminals on stator leads.
Refer toTable
[Remedy]
If stator is defective, replace withnew one.
Fig.
w If an instrument
NORMAL CAPACITYOF CONDENSER
1OpF
w If you do not. have such an instrument, you can check condenser by replacing with new one and test running.
If the generator perform normally withnewcondenser, the cause of trouble is defect in original condenser.
1)Remove rear cover and stator.
- 48 -