-11= TROUBLESHOOTING

11-1NO AC OUTPUT

11-1-1CHECKING STATOR

1)Remove control panel and disconnect couplers on wiring.

2)Measuretheresistancebetween terminals on stator leads.

Refer toTable 9-1 (page 28) for normal re- sistance.

[Remedy]

If stator is defective, replace withnew one.

Fig. 11-1

11-1-2CHECKING CONDENSER

w If an instrument (Q.C.-meter or C-meter) for measuring capacity of condenser is available, check the capacity of condenser.

NORMAL CAPACITYOF CONDENSER

1OpF

w If you do not. have such an instrument, you can check condenser by replacing with new one and test running.

If the generator perform normally withnewcondenser, the cause of trouble is defect in original condenser.

11-1-3CHECKING ROTOR

1)Remove rear cover and stator.

- 48 -

Image 50
Contents Model Section Title Specifications 1300 WPerformance Curves Features General Description 1EXTERNAL View of GeneratorTank \ \ Construction and Function2CONDENSER Control Panel Voltagefluctuationsunderload DC Output 4ELECTRONIC Ignition System OIL Sensor Option 1DESCRIPTION Oil 5CAUTIONS to be Taken on Handling the Sensor Operator may be injured or suffer electric shock Incandescent lamp, heater, etc. withapower factorof 1.O Appliances without any indication asto power consumption Specific Gravity of Batteryelectrolyte 3BATTERY Capacity Measuringprocedures Time to change batteries3METERFREQUENCY Circuittester IPI Measuring Insulation Resistance Control Panel Checkingfunctionalmembers DC Terminal Measure the resistance of the resister 10 ,uF Checkingtableforanaloguecircuittester Disassembly and Assembly 10-2DISASSEMBLY Procedures Green Driver + Driver Two M8 nuts LOmm box wrench 12mm box wrench + Driver LOmm box wrench Box spanner Stator Rotor Rotor Screw the bolt into the thread Mount Remove mount bracketfrom engine Assemblyprocedures 10-3-1FRONT Bracket Stator 10-3-5ENDCOVER 10-3-9FRONT Cover and Element Cover Control Panel Side Secure the side cover with four M5X8 screws 11= Troubleshooting RemedyMow to adjustengine r.p.m AC circuit breaker Resistor RobinAmerica, Inc