GROUNDED OUTLET BOX
GROUNDING
MEANS
ADAPTER
Fig. C
CHANGING VOLTAGE
The motor supplied with your saw is wired for 120 volt operation. If you desire to operate your saw at 240 volts, it is necessary to reposition voltage changing switch in the motor junction box (B) Fig. E. Proceed as follows:
1. WARNING: DISCONNECT TOOL FROM POWER SOURCE.
2.Remove screw (A) Fig. E, and remove nameplate cover (B).
3.Carefully slide switch (C) Fig. F, in motor junction box to read 240. Replace nameplate cover and screw which were removed in STEP 2.
4.It is also necessary to replace the 120 volt plug supplied with the motor with a UL/CSA listed plug suitable for 240 volts and the rated current of the saw. Contact your local Authorized Delta Service Center or qualified electrician for proper procedures to install the plug. The saw must comply with all local and national electrical codes after the 240 volt plug is assembled.
OVERLOAD PROTECTION
The motor on your saw is equipped with a resettable overload relay button (D) Fig. G. If the motor shuts off or fails to start due to overloading, or low voltage, turn the switch to the “OFF” position, let the motor cool three to five minutes then push the reset button (D). The motor can then be turned on again in the usual manner. Some conditions that may cause overloading are; cutting stock too fast, using a dull blade, using the saw beyond its capacity, etc.
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
Fig. D
BA
Fig. E
C
Fig. F
D
Fig. G
5