Carrier 52C manual Accessories, Accessory Form Number Part Number Description

Page 47

 

 

ACCESSORIES

 

 

 

 

ACCESSORY

FORM NUMBER

PART NUMBER

DESCRIPTION

Wall Sleeves

52S-48SI

WALL-SLEEVE-1PK

Non-Insulated Plastic Wall Sleeve, 1 per pack

 

 

WALL-SLEEVE-9PK

Non-Insulated Plastic Wall Sleeve, 9 per pack

 

 

SLEEVE-INSUL-1PK

Insulated Plastic Wall Sleeve, 1 per pack

 

52S-50SI

SLEEVE-STEEL-1PK

Insulated Metal Wall Sleeve, 1 per pack

 

52S-49SI*

SLEEVE-EXT24-1PK

Extended Metal Wall Sleeve for Deep Wall Applications (24 in. deep), 1 per pack

 

52C,P-20SI

FR-SLEEVE-EXT

Friedrich wall sleeve extension to retrofit Carrier PTAC unit into Friedrich 111/2″ deep (T Series) wall

 

 

 

sleeve. 1 per pack

Exterior Grilles†

52S-59SI

GRILLE-ALU-STAMP

Stamped Aluminum Exterior Grille, Clear Finish

 

52S-65SI

GRILLE-PLA-BROWN

Plastic Architectural Rear Grille, Brown

 

 

GRILLE-PLA-BEIGE

Plastic Architectural Rear Grille, Beige

 

52S-60SI

GRILLE-ALU-CLEAR

Aluminum Architectural Exterior Grille, Clear Finish

 

 

GRILLE-ALU-WHITE

Aluminum Architectural Exterior Grille, White

 

 

GRILLE-ALU-BRONZ

Aluminum Architectural Exterior Grille, Light Bronze

 

 

GRILLE-ALU-MBRNZ

Aluminum Architectural Exterior Grille, Medium Bronze

 

 

GRILLE-ALU-BROWN

Aluminum Architectural Exterior Grille, Brown (Dark Bronze)

 

 

GRILLE-ALU-BEIGE

Aluminum Architectural Exterior Grille, Beige

 

 

GRILLE-ALU-ALPIN

Aluminum Architectural Exterior Grille, Alpine (matches Carrier Wall Sleeve)

 

 

GRILLE-ALU-PEACH

Aluminum Architectural Exterior Grille, Peach

 

 

GRILLE-ALU-MELON

Aluminum Architectural Exterior Grille, Melon

 

 

GRILLE-ALU-LGREY

Aluminum Architectural Exterior Grille, Light Grey

 

 

GRILLE-ALU-SGREY

Aluminum Architectural Exterior Grille, Slate Gray

 

 

GRILLE-ALU-RDBRK

Aluminum Architectural Exterior Grille, Red Brick

 

 

GRILLE-ALU-BLUE

Aluminum Architectural Exterior Grille, Blue

 

 

GRILLE-ALU-GREEN

Aluminum Architectural Exterior Grille, Green

Subbase

52C,P-1SI

SUBBASE-NON-ELEC

Non-electrical Subbase

 

52C,P-2SI

SUBBASE-230V-15A

Electrical subbase with factory-installed 208/230 V, 15 amp receptacle

 

 

SUBBASE-230V-20A

Electrical subbase with factory-installed 208/230 V, 20 amp receptacle

 

 

SUBBASE-230V-30A

Electrical subbase with factory-installed 208/230 V, 30 amp receptacle

 

 

SUBBASE-265V-15A

Electrical subbase with factory-installed 265 V, 15 amp receptacle

 

 

SUBBASE-265V-20A

Electrical subbase with factory-installed 265 V, 20 amp receptacle

 

 

SUBBASE-265V-30A

Electrical subbase with factory-installed 265 V, 30 amp receptacle

 

52C,P-3SI

SUBBASE-HARDWIRE

Electrical subbase with factory-installed hardwire kit (230/208 V and 265 V)

Subbase

52C,P-4SI

SUBBASE-SWITCH

Field-Installable Switch kit for an electrical subbase

Field-Installed

52C,P-5SI

SUBBASE-FUSE-15A

Field-Installed Fuse Kit (15 amp) for electrical subbase

Kits

 

SUBBASE-FUSE-20A

Field-Installed Fuse Kit (20 amp) for electrical subbase

 

 

 

 

SUBBASE-FUSE-30A

Field-Installed Fuse Kit (30 amp) for electrical subbase

Electrical

52C,P-11SI

HARDWIRE-KIT-1PK

Permanent power connection to the unit (includes 36″ of flexible conduit and unit-mounted

Connections

 

 

connector, 230/208 V and 265 V) 1 per pack

 

52C,P-19SI

CONDUIT-INTF-4PK

Interface kit for field-supplied conduit to provide permanent power connection (230/208 V and 265 V)

 

 

 

to the unit. Kit includes Molex connector for easy connect/disconnect. 4 per pack

Condensate

52S-53SI

DRAIN-KIT-4PK

Attaches to wall sleeve for controlled internal or external disposal of condensate 4 per pack

Drain Kit

 

 

 

Wall

N/A

HH01AD045

Electro-mechanical Wall Thermostat (Heat/Cool and Heat Pump)

Thermostats

 

TSTATCCBPC01-B

Value Series Electronic Thermostat w/Digital display (Heat/Cool Models)

 

 

TSTATCCBPH01-B

Value Series Electronic Thermostat w/Digital display (Heat Pump Models)

 

 

TSTATCCPAC01-B

7-Day Programmable Electronic Thermostat (Heat/Cool Models)

 

 

TSTATCCPHP01-B

7-Day Programmable Electronic Thermostat (Heat Pump Models)

Wall Thermostat

52C,P-16SI

RC-FIELDKIT230HC

Field-installed wall thermostat retrofit kit to convert a standard 230 V Heat/Cool unit to an

Interface

 

 

RC unit. Wall thermostat sold separately (can be used to convert a cool only unit to RC).

Retrofit Kit

 

RC-FIELDKIT230HP

Field-installed wall thermostat retrofit kit to convert a standard 230-V Heat Pump unit to an

 

 

 

RC unit. Wall thermostat sold separately.

 

 

RC-FIELDKIT265HC

Field-installed wall thermostat retrofit kit to convert a standard 265 V Heat/Cool unit to an

 

 

 

RC unit. Wall thermostat sold separately (can be used to convert a cool only unit to RC).

 

 

RC-FIELDKIT265HP

Field-installed wall thermostat retrofit kit to convert a standard 265-V Heat Pump unit to a

 

 

 

RC unit. Wall thermostat sold separately.

 

N/A

TSTAT-COVER-6X7

Clear plastic locking thermostat cover prevents unauthorized access to thermostat. Cover for use with

 

 

 

non-programmable and electro-mechanical thermostats. Outside dimensions: 61/2″ x 71/2″ x 215/16″.

 

 

 

1 per pack

 

N/A

TSTAT-COVER-7X10

Clear plastic locking thermostat cover prevents unauthorized access to thermostat. Cover for use with

 

 

 

programmable thermostats. Outside dimensions: 71/4″ x 93/4″ x 33/8″. 1 per pack

Replacement

N/A

AIR-FILTER-10PK

Replacement air filters in package of 10

Filters

 

 

 

Energy

52C,P-24SI

EM-KIT

Allows unit to be turned on and off from a remote location (includes freeze guard protection)

Management

 

 

 

Locking Security

52C,P-23SI

SECURITY-DOOR

Key-locking security door to prevent access to heating and cooling controls

Control Door

 

 

 

Lateral Duct Kit

52C,P-14SI

LATERAL-DUCT

Ductwork to allow one unit to heat and cool two rooms (plenum plus extension duct and registers)

Air/Curtain

52C,P-9SI

DEFLECTOR-1PK

Lateral air deflector, with individually adjustable louvers, to enhance air circulation, 1 per pack

Deflector

 

 

 

N/A

CURTDFL-52CP-1PK

Curtain deflector for 52C and 52P models — prevents curtains from blowing into discharge airstream.

 

 

 

 

1 per pack.

 

 

 

NOTE: Curtain deflector for previous models are also available. Contact Carrier Representative.

*Extended metal wall sleeve also available in 26 in. and 28 in. depth.

†Custom colors are also available.

47

Image 47
Contents Contents Service Technician GuideSummary of DANGERS, WARNINGS, and Cautions IntroductionTools Needed Unit DisassemblyDisconnect Power for CORD-CONNECTED Unit Disconnect Power for Permanently Connected Hardwired UnitsRemove the Unit from the Wall Sleeve Open the Control BOXRemove the Discharge Deck Assembly Accessing Unit ComponentsAccessing INDOOR-AIR Section Components Accessing OUTDOOR-AIR Section ComponentsRemove the AIR Discharge Grille Ptac Unit with Lateral Duct Accessory InstalledGusset Removal Location of Screws on Discharge Grille Reinstall Front PanelComponent Cleaning Schedule General CleaningCleaning and Safety Cleaning the Outdoor AIR Vent Filter Monthly CleaningAccess and Clean Indoor FAN and FAN Scroll Seasonal CleaningCleaning the Indoor and Outdoor Coils Ptac Exterior Surfaces Rotary Compressor Components CompressorBasic Hermetic Compressor Electrical Measurements Compressor TroubleshootingDisconnect ALL Power to the Unit Basic Compressor Troubleshooting Guide Compressor ReplacementSHORTED/OPEN Windings Test Strainer Capillary Tube Location Heater Removal HeatersCommon Causes Heater Failure Acceptable Heater Resistance Values Disconnect ALL Power to UnitUNIT-MOUNTED Controls Operating ControlsWALL-MOUNTED Thermostat Controls Remote Thermostat TroubleshootingDo not daisy chain R 24 VAC NON-USER Adjustable Controls Description of Selector Switch Settings FigureTools Needed Component Operation and TroubleshootingSequence of Operation Indoor Thermostat IT CONTACTS, ALL 52CE, PE Models Indoor Thermostat IT CONTACTS, ALL 52CQ, PQ Models Capacitor Test Electrical Components Removal and ReplacementComponent Locations Open Control BOX Basic FAN Motor Electrical Tests FAN Motor TroubleshootingFAN Motor Typical 265 Volt Motors FAN Motor Troubleshooting Chart Typical 208/230 Volt MotorsLocation of Wiring Schematic On Front Panel of Control BOX FAN Motor ReplacementField Temperature Charts 100 110 120 130 52P 12,000 BTU Unit Field Temperature Chart High Cool 50% RH Indoor Series Indoor 52C,P Series Page 000 Btu 52P-12,000 Btu 52C-12,000 Btu 15,000 Btu Refer to Figures 68-72 for Typical Wiring Schematics Wiring DiagramsComponent Legend CAP Component Connection Marked Fan Motor Page Most Frequent Ptac Service Questions Accessory Form Number Part Number Description AccessoriesAmps 52C Performance and Physical Data52PE-512---3 52P Performance and Physical DataPage Page Copyright 2002 Carrier Corporation