Carrier manual 52C Performance and Physical Data, Amps

Page 48

52C,P

SERIES

52C PERFORMANCE AND PHYSICAL DATA

CATALOG

COOLING

 

 

ELECTRIC

 

REVERSE

EVAP. FAN

APPROX.

1-PH, 60 Hz

CURRENT (AMPS)

INPUT POWER (WATTS)

BRANCH

R-22

NUMBER

(Btuh)

EER

HEAT (Btuh)

COP

CYCLE

CFM

WEIGHT

VOLTS

Cooling

Electric

Cooling

Electric

CIRCUIT FUSE

CHARGE

 

 

 

 

 

 

 

HEAT (Btuh)

(HI-SPEED)

(SHIP)

 

Heat

Heat

(AMPS)

(oz)

52CE-207---3

7,000/ 6,900

11.1/11.1

7,800/

6,400

260/250

125

230/208

2.7/2.9

10.4/ 9.5

631/ 622

2393/1985

15

24

52CE-307---3

7,000/ 6,900

11.1/11.1

11,600/

9,700

260/250

125

230/208

2.7/2.9

15.2/14.1

631/ 622

3493/2935

20

24

52CE-209---3

9,000/ 8,900

10.7/10.7

7,800/

6,400

260/250

125

230/208

3.7/3.8

10.4/ 9.5

841/ 832

2393/1985

15

24

52CE-309---3

9,000/ 8,900

10.7/10.7

11,600/

9,700

260/250

125

230/208

3.7/3.8

15.2/14.1

841/ 832

3493/2935

20

24

52CE-212---3

12,000/11,900

10.1/10.1

7,800/

6,400

350/320

140

230/208

5.2/5.6

10.8/ 9.9

1188/1178

2470/2047

15

34

52CE-312---3

12,000/11,900

10.1/10.1

11,600/

9,700

350/320

140

230/208

5.2/5.6

15.6/14.5

1188/1178

3570/2997

20

34

52CE-512---3

12,000/11,900

10.1/10.1

17,000/13,600

350/320

140

230/208

5.2/5.6

22.5/20.0

1188/1178

5170/4147

30

34

52CE-215---3

14,500/14,000

9.4/

9.5

7,800/

6,400

350/320

150

230/208

6.8/7.6

10.9/10.0

1543/1473

2517/2117

15

35

52CE-315---3

14,500/14,000

9.4/

9.5

11,600/

9,700

350/320

150

230/208

6.8/7.6

15.7/14.6

1543/1473

3617/3067

20

35

52CE-515---3

14,500/14,000

9.4/

9.5

17,000/13,600

350/320

150

230/208

6.8/7.6

22.6/20.1

1543/1473

5217/4217

30

35

52CE-207---4

7,000

11.1

7,800

260

125

265

2.4

9.2

631

2396

15

26

52CE-307---4

7,000

11.1

11,600

260

125

265

2.4

13.3

631

3496

20

26

52CE-209---4

8,900

10.7

7,800

260

125

265

3.1

9.2

832

2396

15

24

52CE-309---4

8,900

10.7

11,600

260

125

265

3.1

13.3

832

3496

20

24

52CE-212---4

12,000

10.1

7,800

340

140

265

4.6

9.4

1188

2470

15

34

52CE-312---4

12,000

10.1

11,600

340

140

265

4.6

13.5

1188

3570

20

34

52CE-512---4

12,000

10.1

17,000

340

140

265

4.6

19.6

1188

5170

25

34

52CE-215---4

14,500

9.4

7,800

340

150

265

6.0

9.7

1543

2517

15

36

52CE-315---4

14,500

9.4

11,600

340

150

265

6.0

13.8

1543

3617

20

36

52CE-515---4

14,500

9.4

17,000

340

150

265

6.0

19.9

1543

5217

25

36

FIGURE 73 — 52CE — PERFORMANCE AND PHYSICAL DATA FOR STANDARD HEAT/COOL UNITS

CATALOG

COOLING

 

 

ELECTRIC

 

REVERSE

EVAP. FAN

APPROX.

1-PH, 60 Hz

CURRENT (AMPS)

INPUT POWER (WATTS)

BRANCH

R-22

NUMBER

(Btuh)

EER

HEAT (Btuh)

COP

CYCLE

CFM

WEIGHT

VOLTS

Cooling

Electric

Cooling

Electric

CIRCUIT FUSE

CHARGE

 

 

 

 

 

 

 

 

HEAT (Btuh)

(HI-SPEED)

(SHIP)

 

Heat

Heat

(AMPS)

(oz)

52CQ-207---3

7,000/

6,900

11.1/11.1

7,800/

6,400

3.1/3.1

6,100/

6,000

260/250

125

230/208

2.7/2.9

10.4/ 9.5

631/

622

2393/1985

15

24

52CQ-307---3

7,000/

6,900

11.1/11.1

11,600/

9,700

3.1/3.1

6,100/

6,000

260/250

125

230/208

2.7/2.9

15.2/14.1

631/

622

3493/2935

20

24

52CQ-209---3

9,000/

8,900

10.7/10.7

7,800/

6,400

3.1/3.1

7,900/

7,800

260/250

125

230/208

3.7/3.8

10.4/ 9.5

841/

832

2393/1985

15

24

52CQ-309---3

9,000/

8,900

10.7/10.7

11,600/

9,700

3.1/3.1

7,900/

7,800

260/250

125

230/208

3.7/3.8

15.2/14.1

841/

832

3493/2935

20

24

52CQ-212---3

12,000/11,900

10.1/10.1

7,800/

6,400

3.0/3.0

10,800/10,700

350/320

140

230/208

4.7/5.2

10.8/ 9.9

1188/1178

2470/2047

15

34

52CQ-312---3

12,000/11,900

10.1/10.1

11,600/ 9,700

3.0/3.0

10,800/10,700

350/320

140

230/208

4.7/5.2

15.6/14.5

1188/1178

3570/2997

20

34

52CQ-512---3

12,000/11,900

10.1/10.1

17,000/13,600

3.0/3.0

10,800/10,700

350/320

140

230/208

4.7/5.2

22.5/20.0

1188/1178

5170/4147

30

34

52CQ-215---3

14,500/14,000

9.4/

9.5

7,800/

6,400

2.9/2.9

13,400/13,200

350/320

150

230/208

6.8/7.6

10.9/10.0

1543/1473

2517/2117

15

35

52CQ-315---3

14,500/14,000

9.4/

9.5

11,600/

9,700

2.9/2.9

13,400/13,200

350/320

150

230/208

6.8/7.6

15.7/14.6

1543/1473

3617/3067

20

35

52CQ-515---3

14,500/14,000

9.4/

9.5

17,000/13,600

2.9/2.9

13,400/13,200

350/320

150

230/208

6.8/7.6

22.6/20.1

1543/1473

5217/4217

30

35

52CQ-207---4

7,000

11.1

7,800

3.1

6,100

260

125

265

2.4

9.2

631

2396

15

26

52CQ-307---4

7,000

11.1

11,600

3.1

6,100

260

125

265

2.4

13.3

631

3496

20

26

52CQ-209---4

8,900

10.7

7,800

3.1

7,700

260

125

265

3.1

9.2

832

2396

15

24

52CQ-309---4

8,900

10.7

11,600

3.1

7,700

260

125

265

3.1

13.3

832

3496

20

24

52CQ-212---4

12,000

10.1

7,800

3.0

10,800

340

140

265

4.5

9.4

1188

2470

15

34

52CQ-312---4

12,000

10.1

11,600

3.0

10,800

340

140

265

4.5

13.5

1188

3570

20

34

52CQ-512---4

12,000

10.1

17,000

3.0

10,800

340

140

265

4.5

19.6

1188

5170

25

34

52CQ-215---4

14,500

9.4

7,800

2.9

13,400

340

150

265

6.0

9.7

1543

2517

15

36

52CQ-315---4

14,500

9.4

11,600

2.9

13,400

340

150

265

6.0

13.8

1543

3617

20

36

52CQ-515---4

14,500

9.4

17,000

2.9

13,400

340

150

265

6.0

19.9

1543

5217

25

36

FIGURE 74 — 52CQ — PERFORMANCE AND PHYSICAL DATA FOR STANDARD HEAT PUMP UNITS

48

Image 48
Contents Service Technician Guide ContentsIntroduction Summary of DANGERS, WARNINGS, and CautionsUnit Disassembly Disconnect Power for CORD-CONNECTED UnitDisconnect Power for Permanently Connected Hardwired Units Tools NeededOpen the Control BOX Remove the Unit from the Wall SleeveAccessing Unit Components Accessing INDOOR-AIR Section ComponentsAccessing OUTDOOR-AIR Section Components Remove the Discharge Deck AssemblyPtac Unit with Lateral Duct Accessory Installed Remove the AIR Discharge GrilleGusset Removal Reinstall Front Panel Location of Screws on Discharge GrilleGeneral Cleaning Cleaning and SafetyComponent Cleaning Schedule Monthly Cleaning Cleaning the Outdoor AIR Vent FilterSeasonal Cleaning Cleaning the Indoor and Outdoor CoilsAccess and Clean Indoor FAN and FAN Scroll Ptac Exterior Surfaces Compressor Rotary Compressor ComponentsCompressor Troubleshooting Disconnect ALL Power to the UnitBasic Hermetic Compressor Electrical Measurements Compressor Replacement Basic Compressor Troubleshooting GuideSHORTED/OPEN Windings Test Strainer Capillary Tube Location Heaters Common Causes Heater FailureHeater Removal Disconnect ALL Power to Unit Acceptable Heater Resistance ValuesOperating Controls UNIT-MOUNTED ControlsRemote Thermostat Troubleshooting WALL-MOUNTED Thermostat ControlsDo not daisy chain R 24 VAC Description of Selector Switch Settings Figure NON-USER Adjustable ControlsComponent Operation and Troubleshooting Sequence of OperationTools Needed Indoor Thermostat IT CONTACTS, ALL 52CE, PE Models Indoor Thermostat IT CONTACTS, ALL 52CQ, PQ Models Electrical Components Removal and Replacement Capacitor TestComponent Locations Open Control BOX FAN Motor Troubleshooting FAN MotorBasic FAN Motor Electrical Tests FAN Motor Troubleshooting Chart Typical 208/230 Volt Motors Typical 265 Volt MotorsFAN Motor Replacement Location of Wiring Schematic On Front Panel of Control BOXField Temperature Charts 100 110 120 130 52P 12,000 BTU Unit Field Temperature Chart High Cool 50% RH Indoor Series Indoor 52C,P Series Page 000 Btu 52P-12,000 Btu 52C-12,000 Btu 15,000 Btu Wiring Diagrams Refer to Figures 68-72 for Typical Wiring SchematicsComponent Legend CAP Component Connection Marked Fan Motor Page Most Frequent Ptac Service Questions Accessories Accessory Form Number Part Number Description52C Performance and Physical Data Amps52P Performance and Physical Data 52PE-512---3Page Page Copyright 2002 Carrier Corporation