Carrier 52C manual Reinstall Front Panel, Location of Screws on Discharge Grille

Page 8

52C,P

SERIES

CONDENSER

FAN

OUTDOOR COIL TUBE

SHEET SCREWS

HUB CLAMP

FIGURE 16 — LOCATION OF OUTDOOR

COIL TUBE SHEET SCREWSFIGURE 18 — REMOVING CONDENSER FAN HUB CLAMP

CONTROL DOOR

SCREW

SCREW

HINGE PINS

 

 

 

 

 

 

 

 

FRONT PANEL

DISCHARGE

(BACK VIEW)

GRILLE

FIGURE 19 — LOCATION OF SCREWS ON

DISCHARGE GRILLE

REINSTALL FRONT PANEL

1. Grasp the front panel firmly at the center of the top and bottom of the panel, tilting it forward 5 to 10 degrees from the vertical. See Figure 4.

2. Place the top of the front panel onto the unit, making sure the top engagement posts have engaged the slots on the unit. The top edge of the front panel should be flat against the top of the unit.

3. Gently lower the front panel onto the chassis, ensuring the conduit/cord is routed through the panel notch. Magnetic latches at the bottom of the front panel will secure the front panel to the unit.

FIGURE 17 — REMOVING OUTDOOR COIL

FROM CONDENSER FAN

8

Image 8
Contents Service Technician Guide ContentsIntroduction Summary of DANGERS, WARNINGS, and CautionsUnit Disassembly Disconnect Power for CORD-CONNECTED UnitDisconnect Power for Permanently Connected Hardwired Units Tools NeededOpen the Control BOX Remove the Unit from the Wall SleeveAccessing Unit Components Accessing INDOOR-AIR Section ComponentsAccessing OUTDOOR-AIR Section Components Remove the Discharge Deck AssemblyPtac Unit with Lateral Duct Accessory Installed Remove the AIR Discharge GrilleGusset Removal Reinstall Front Panel Location of Screws on Discharge GrilleComponent Cleaning Schedule General CleaningCleaning and Safety Monthly Cleaning Cleaning the Outdoor AIR Vent FilterAccess and Clean Indoor FAN and FAN Scroll Seasonal CleaningCleaning the Indoor and Outdoor Coils Ptac Exterior Surfaces Compressor Rotary Compressor ComponentsBasic Hermetic Compressor Electrical Measurements Compressor TroubleshootingDisconnect ALL Power to the Unit Compressor Replacement Basic Compressor Troubleshooting GuideSHORTED/OPEN Windings Test Strainer Capillary Tube Location Heater Removal HeatersCommon Causes Heater Failure Disconnect ALL Power to Unit Acceptable Heater Resistance ValuesOperating Controls UNIT-MOUNTED ControlsRemote Thermostat Troubleshooting WALL-MOUNTED Thermostat ControlsDo not daisy chain R 24 VAC Description of Selector Switch Settings Figure NON-USER Adjustable ControlsTools Needed Component Operation and TroubleshootingSequence of Operation Indoor Thermostat IT CONTACTS, ALL 52CE, PE Models Indoor Thermostat IT CONTACTS, ALL 52CQ, PQ Models Electrical Components Removal and Replacement Capacitor TestComponent Locations Open Control BOX Basic FAN Motor Electrical Tests FAN Motor TroubleshootingFAN Motor FAN Motor Troubleshooting Chart Typical 208/230 Volt Motors Typical 265 Volt MotorsFAN Motor Replacement Location of Wiring Schematic On Front Panel of Control BOXField Temperature Charts 100 110 120 130 52P 12,000 BTU Unit Field Temperature Chart High Cool 50% RH Indoor Series Indoor 52C,P Series Page 000 Btu 52P-12,000 Btu 52C-12,000 Btu 15,000 Btu Wiring Diagrams Refer to Figures 68-72 for Typical Wiring SchematicsComponent Legend CAP Component Connection Marked Fan Motor Page Most Frequent Ptac Service Questions Accessories Accessory Form Number Part Number Description52C Performance and Physical Data Amps52P Performance and Physical Data 52PE-512---3Page Page Copyright 2002 Carrier Corporation