Hitachi EM 490 dimensions If the pressure is not 2350 psi 164 bar

Page 23

PRESSURE CONTROL ADJUSTMENT

ON/OFF SWITCH

A

B

D

TIGHTEN

C

Fig 22

4.Open the needle valve slightly. Turn the pressure con- trol knob (A) to the minimum setting.

5.Plug in the sprayer and turn the switch ON. Increase the pressure setting just enough to start the sprayer. Prime the hose, being sure to eliminate all air from the system.

6.Open the needle valve a little more±±enough to allow the pump to run continuously±±and turn the pressure control knob to maximum. Now, very slowly start to close the needle valve, but don't close it all the way. Observe the pressure at which the pump stalls, which should be approximately 2750 psi (190 bar).

NOTE: The slower the pressure is raised, the easier it is to note the exact stall pressure. Closing the needle valve quickly causes the pressure to rise too fast which gives a false reading.

If the pressure is lower than 2750 psi (190 bar): Unplug the sprayer. Relieve pressure. Insert the wrench and untighten the pressure adjustment nut 1/8 turn or less, then repeat steps 5 and 6.

If the pressure is higher than 2750 psi (190 bar): Unplug the sprayer. Relieve pressure. Insert the wrench and tighten the pressure adjustment nut 1/8 turn or less and repeat steps 5 and 6. Repeat this pro- cedure until the proper stall pressure is obtained.

7.Now check to see at what pressure the sprayer starts to run again after it stalls. Plug in the sprayer, turn it on, close the needle valve, and set the pressure at maximum. Allow the sprayer to run until it stalls.

8.Open the needle valve very slowly while observing the pressure gauge. Check to see if the pressure drops to approximately 2350 psi (164 bar) before starting again.

If the pressure is not 2350 psi (164 bar):

Shut off and unplug the sprayer, but do not relieve pressure. Turn the differential wheel (D) just one notch and repeat Steps 5 and 6. Check the pressure drop again, and repeat if necessary.

NOTE: If you adjust the differential wheel, recheck the stall pressure (steps 5 and 6) to be sure the stall pressure has not changed.

9.Follow the Pressure Relief Procedure Warning on page 14. Flush the water out with mineral spirits. Re- lieve pressure again. Install the plug (135) and the pressure control cover (41). Remove the test hose, needle valve and pressure gauge.

307-735 23

Image 23
Contents Model 231±050 Model 231±002, Series CModel 231±490 Model 220±679, Series CMedical Alert±±Airless Spray Wounds General SafetySpray Gun Safety Devices Spray Tip SafetyHose Grounding Continuity Flushing SafetySystem Pressure Fluid and Solvent CompatibilityConsignes de sécurité concernant lajutage du pulvérisateur Consignes générales de sécuritéSoins médicaux Dispositifs de sécurité du pistoletMise à la terre ou à la masse PressionCompatibilité chimique des corps Continuité de la mise à la terre des tuyauxAparatos de seguridad de la pistola pulverizadora EL Rociado a Alta Presion Puede Causar Graves LesionesSeguridad general Tratamiento médicoSeguridad durante el lavado Presión del sistemaCompatibilidad de fluido Puesta a tierraConnect the hose and gun See Fig SetupOperation Pressure Relief ProcedurePrime the sprayer with paint Install the spray tip and tip guardAdjusting the spray pattern Refer to Fig Shutdown and Care Cleaning a Clogged TipStartup after storage When To FlushHow To Flush Flushing GuidelinesCorrect Wrong Application MethodsProblem Cause Solution Troubleshooting GuidePressure Relief Procedure Removing the Pump. See Fig Displacement PumpReassembly Notes Reinstalling the Pump. See FigReassembly Procedure Replacing the Connecting ROD and Bearing Replacing the Drive Assembly Capacitor Replacing the Electric Motor & CapacitorReplacing the Pressure Control & Circuit Board Follow the Pressure Relief Procedure Warning on Pressure Control AdjustmentService Tools Needed If the pressure is not 2350 psi 164 bar Circuit Board Applications Parts Drawing ± Pressure ControlNO. Part no Description QTY Displacement Pump Parts Drawing and ListModel 231±490, Complete Sprayer Parts List ± Sprayer with Upright CartParts Drawing Model 231±002, Series C, Basic SprayerParts Drawing ± Sprayer with Upright Cart Model 231±050, Complete Sprayer Parts List ± Sprayer with Loboy CartModel 220±679, Series C, Basic Sprayer Parts Drawing ± Sprayer with Loboy Cart Service Information AccessoriesTo you 1±800±328±0211 Toll Free Technical DataDimensions Important Phone NumbersGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440±1441 Graco Warranty and Disclaimers