Hitachi EM 490 dimensions Operation, Pressure Relief Procedure

Page 9

SETUP

FILTER

DO NOT INSTALL

A SHUT OFF

DEVICE HERE

ON/OFF SWITCH

PACKING NUT/WETCUP

Keep filled with TSL

PRESSURE CONTROL KNOB

50 ft. (15.2 m)

MAIN FLUID HOSE

 

3 ft (0.9 m) HOSE

Fig 1

RAC IV DripLess TIP GUARD and SwitchTip

 

OPERATION

WARNING

Pressure Relief Procedure

To reduce the risk of serious bodily injury, including in- jection; splashing in the eyes or on the skin; injury from moving parts or electric shock, always follow this pro- cedure whenever you shut off the sprayer, when checking or servicing any part of the spray system, when installing, cleaning or changing spray tips, and whenever you stop spraying.

1.Engage the gun safety latch.

2.Turn the ON/OFF switch to OFF.

3.Unplug the power supply cord.

4.Disengage the gun safety latch. Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure.

5.Engage the gun safety latch.

6.Open the pressure drain valve, having a container ready to catch the drainage. Leave the pressure drain valve open until you are ready to operate the sprayer again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved af- ter following the steps above, VERY SLOWLY loosen the tip guard retaining nut or hose end coupling and re- lieve pressure gradually. Then loosen the nut com- pletely. Now clear the tip or hose obstruction.

307-735 9

Image 9
Contents Model 231±490 Model 231±002, Series CModel 220±679, Series C Model 231±050Spray Gun Safety Devices General SafetySpray Tip Safety Medical Alert±±Airless Spray WoundsSystem Pressure Flushing SafetyFluid and Solvent Compatibility Hose Grounding ContinuitySoins médicaux Consignes générales de sécuritéDispositifs de sécurité du pistolet Consignes de sécurité concernant lajutage du pulvérisateurCompatibilité chimique des corps PressionContinuité de la mise à la terre des tuyaux Mise à la terre ou à la masseSeguridad general EL Rociado a Alta Presion Puede Causar Graves LesionesTratamiento médico Aparatos de seguridad de la pistola pulverizadoraCompatibilidad de fluido Presión del sistemaPuesta a tierra Seguridad durante el lavadoConnect the hose and gun See Fig SetupOperation Pressure Relief ProcedureInstall the spray tip and tip guard Adjusting the spray pattern Refer to FigPrime the sprayer with paint Shutdown and Care Cleaning a Clogged TipHow To Flush When To FlushFlushing Guidelines Startup after storageCorrect Wrong Application MethodsTroubleshooting Guide Pressure Relief ProcedureProblem Cause Solution Removing the Pump. See Fig Displacement PumpReassembly Notes Reinstalling the Pump. See FigReassembly Procedure Replacing the Connecting ROD and Bearing Replacing the Drive Assembly Capacitor Replacing the Electric Motor & CapacitorReplacing the Pressure Control & Circuit Board Pressure Control Adjustment Service Tools NeededFollow the Pressure Relief Procedure Warning on If the pressure is not 2350 psi 164 bar Circuit Board Applications Parts Drawing ± Pressure ControlNO. Part no Description QTY Displacement Pump Parts Drawing and ListParts Drawing Parts List ± Sprayer with Upright CartModel 231±002, Series C, Basic Sprayer Model 231±490, Complete SprayerParts Drawing ± Sprayer with Upright Cart Parts List ± Sprayer with Loboy Cart Model 220±679, Series C, Basic SprayerModel 231±050, Complete Sprayer Parts Drawing ± Sprayer with Loboy Cart Service Information AccessoriesDimensions Technical DataImportant Phone Numbers To you 1±800±328±0211 Toll FreeGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440±1441 Graco Warranty and Disclaimers