Graco 309063F important safety instructions On/Off Switch Replacement, Removal, Installation

Page 14

On/Off Switch Replacement

120 Vac

Removal

1. Relieve pressure; page 6.

2.Fig. 10 and 11. Remove four screws (18) and pressure control cover (39).

3.Disconnect two wires (A) from ON/OFF switch (23).

4.Remove toggle boot (25) and locking ring (24). Remove ON/OFF switch (23).

Installation

1.Install new ON/OFF switch (23). Install locking ring (24) and toggle boot (25).

2.Connect two wires (A) to ON/OFF switch.

3.Install pressure control cover (39) with four screws (18).

25

24

 

35

37

 

A

 

23

36

 

 

 

18

 

 

22

D E

52

39

ti0057b

Fig. 10

14309063

Image 14
Contents Repair 309063FSpecifications 309063Fire and Explosion Hazard Pressurized Aluminum Parts Hazard Component Identification and Function Pressure Relief Procedure Skin Injection HazardGeneral Repair Information Read Electric Shock Warning Burn Hazard WarningSprayer requires Sprayer cord includes a grounding wire with anGrounding and Electric Requirements Never use an outlet that is not grounded or an adapterTroubleshooting Motor WON’T OperateLOW or Fluctuating Output Placement Electric Shock Hazard Motor Brush ReplacementSpin Test Read General Repair InformationInstall pump 13 Displacement Pump Re- placement, 309063 Removal On/Off Switch ReplacementInstallation 232901, a Capacitor on Motor232900, A, B 233797, aWhite ON/OFF Black Switch Green Power Cord Motor Connector 100 Vac 240 Vac TP1 TP2Pressure Control Repair LED Sprayer Operation Indicates BlinksInstall motor control board 35 with five screws Pressure Adjust Potentiometer Installation Installation See Fig Removal See FigAssembly Drive Housing ReplacementDisassembly Remove pump 13 Displacement Pump Re- placement,Remove drive housing Drive Housing Replace- ment, Motor ReplacementRemove pump Displacement Pump Replace- ment, Install fluid manifold Pressure Control Replace- ment,Displacement Pump Replacement RemovalTechnical Data DimensionsGraco Information