Graco 309063F Motor Replacement, Remove pump Displacement Pump Replace- ment

Page 25

Motor Replacement

Disassembly

1. Relieve pressure; page 6.

2.Remove pump; Displacement Pump Replace- ment, page 26.

CAUTION

Do not drop gear cluster (7) when removing drive housing (10). Gear cluster may stay engaged in motor front end bell or drive housing.

3.Remove drive housing; Drive Housing Replace- ment, page 24.

4.Remove fluid manifold; Pressure Control Re- placement, page 23.

5.Remove control board; Control Board Replace- ment, page 20 or 22.

6.Remove strain relief (37; Fig. 10, 13 or 14) and motor fan (2).

21

35

36

18

39

22

63

1Liberally apply grease

Fig. 17

7.Remove three screws (22) behind board and remove control housing (21).

8.Remove four screws (22) and motor (1) from frame (63).

Assembly

1.Install new motor (1) on frame (63) with four screws (22).

2.Install control housing (21) with three screws (22).

3.Install strain relief (37; Fig. 10, 13 or 14) and motor fan (2).

4.Install fluid manifold; Pressure Control Replace- ment, page 23.

5.Install control board; Control Board Replace- ment, page 20 or 22.

6.Install drive housing (10); Drive Housing Re- placement, page 24.

7.Install pump (13); Displacement Pump Replace- ment, page 26.

1

1

1

22

ti0054b

309063 25

Image 25
Contents 309063F Repair309063 SpecificationsFire and Explosion Hazard Pressurized Aluminum Parts Hazard Component Identification and Function Skin Injection Hazard Pressure Relief ProcedureRead Electric Shock Warning Burn Hazard Warning General Repair InformationGrounding and Electric Requirements Sprayer cord includes a grounding wire with anSprayer requires Never use an outlet that is not grounded or an adapterMotor WON’T Operate TroubleshootingLOW or Fluctuating Output Placement Spin Test Motor Brush ReplacementElectric Shock Hazard Read General Repair InformationInstall pump 13 Displacement Pump Re- placement, 309063 Installation On/Off Switch ReplacementRemoval 232900, A, B Capacitor on Motor232901, a 233797, aWhite ON/OFF Black Switch Green Power Cord Motor Connector 100 Vac TP1 TP2 240 VacLED Sprayer Operation Indicates Blinks Pressure Control RepairInstall motor control board 35 with five screws Pressure Adjust Potentiometer Installation Removal See Fig Installation See FigDisassembly Drive Housing ReplacementAssembly Remove pump 13 Displacement Pump Re- placement,Remove pump Displacement Pump Replace- ment, Motor ReplacementRemove drive housing Drive Housing Replace- ment, Install fluid manifold Pressure Control Replace- ment,Removal Displacement Pump ReplacementDimensions Technical DataGraco Information