Component Identification and Function

R P S

N

M

AMotor

BDrive Assembly

DDisplacement Pump

EFluid Outlet

FPrime Valve

GFluid Filter (optional)

HPressure Adjusting Knob

JPressure Control

KON/OFF Switch

M50 ft (15 m) Main Hose

NSpray Gun

PRAC IV Switch Tip R Tip Guard

S Thumb Lock Safety T Power Cord Rack U Suction Hose

V Drain Tube

 

H

 

A

 

J

V

B

 

U

T

K

F

D

ti7400a

ti5914a

E G

DC motor, permanent magnet, fan cooled

Transfers power from DC motor to displacement pump Transfers fluid to be sprayed from source through spray gun Spray gun is connected here

Used to prime and drain sprayer (also relieves fluid outlet pressure) when open

Final filter of fluid to spray gun Controls fluid outlet pressure

Controls motor speed to maintain fluid outlet pressure at displacement pump outlet. Works with pressure adjusting knob.

Power switch that controls main power to sprayer

1/4 in. ID, grounded, nylon hose with spring guards on both ends High pressure spray gun with gun safety latch

Uses high pressure fluid to clear tip clogs without removing tip from spray gun Tip guard reduces risk of injection injury

Gun safety latch inhibits accidental triggering of spray gun Holds wrapped power cord for storage

Transfers fluid to be sprayed from source to pump Fluid outlet used to drain and prime the sprayer

309063 5

Image 5
Contents 309063F Repair309063 SpecificationsFire and Explosion Hazard Pressurized Aluminum Parts Hazard Component Identification and Function Skin Injection Hazard Pressure Relief ProcedureRead Electric Shock Warning Burn Hazard Warning General Repair InformationGrounding and Electric Requirements Sprayer cord includes a grounding wire with anSprayer requires Never use an outlet that is not grounded or an adapterMotor WON’T Operate TroubleshootingLOW or Fluctuating Output Placement Spin Test Motor Brush ReplacementElectric Shock Hazard Read General Repair InformationInstall pump 13 Displacement Pump Re- placement, 309063 Removal On/Off Switch ReplacementInstallation 232900, A, B Capacitor on Motor232901, a 233797, aWhite ON/OFF Black Switch Green Power Cord Motor Connector 100 Vac TP1 TP2 240 VacLED Sprayer Operation Indicates Blinks Pressure Control RepairInstall motor control board 35 with five screws Pressure Adjust Potentiometer Installation Removal See Fig Installation See FigDisassembly Drive Housing ReplacementAssembly Remove pump 13 Displacement Pump Re- placement,Remove pump Displacement Pump Replace- ment, Motor ReplacementRemove drive housing Drive Housing Replace- ment, Install fluid manifold Pressure Control Replace- ment,Removal Displacement Pump ReplacementDimensions Technical DataGraco Information