Pressure Control Repair
For these models and series only: 232900 A, B, C, D, E
232901 A, B, C, D
233797 A, B, C, D
233815 A, B, C, D
232903 A, B
232906 A, B
Pressure Control Transducer
Removal
Refer to Fig. 10 and 11, 13 or 14 depending on sprayer voltage.
1. Relieve pressure; page 6.
2.Remove four screws (18) and cover (39).
3.Disconnect lead (E) from motor control board (35).
4.Remove two screws (22) and filter housing (45).
5.Thread transducer lead plastic connector down through transducer grommet (28).
6.Remove pressure control transducer (52) and packing
Installation
1.Install packing
2.Thread transducer lead plastic connector up through transducer grommet (28).
3.Install filter housing (45) with two screws (22).
4.Connect lead (E) to motor control board (35).
5.Install cover (39) with four screws (18).
Pressure Adjust Potentiometer
Removal
Refer to Fig. 10 and 11, 13 or 14 depending on sprayer voltage.
1. Relieve pressure; page 6.
2.Remove four screws (18) and cover (39).
3.Disconnect all leads from motor control board (35).
4.Remove five screws (36) and board (35)
5.Remove potentiometer knob (27), sealing shaft nut (33) and pressure adjust potentiometer (26).
Installation
1.Install pressure adjust potentiometer (26), sealing shaft nut (33) and potentiometer knob (27).
a.Turn potentiometer fully clockwise.
b.Install knob at full clockwise position.
2.Install board (35) with five screws (36).
3.Connect all leads to motor control board (35).
4.Install cover (39) with four screws (18).