Graco 309063F important safety instructions Pressure Relief Procedure, Skin Injection Hazard

Page 6

Pressure Relief Procedure

WARNING

SKIN INJECTION HAZARD

Follow this Pressure Relief Procedure whenever you are instructed to relieve pressure, stop spraying, check or ser- vice equipment, or install or clean spray tip. read

Injection Hazard Warning.

1.Turn OFF power and turn pressure control to low- est pressure setting.

2.Hold gun against side of grounded metal flushing pail. Trigger gun to relieve pressure.

 

ti7401a

Fig. 1

FLUSH

3. Turn prime valve down

Fig. 2

If suspected that spray tip or hose is clogged or that pressure has not been fully relieved after following

steps above , VERY SLOWLY loosen tip guard retain- ing nut or hose end coupling to relieve pressure gradu- ally, then loosen completely. Clear tip or hose obstruc- tion.

4.Engage trigger safety lock on gun if unit is being shut down or left unattended.

CAUTION

To reduce risk of pressure control malfunction:

DUse needle nose pliers to disconnect wire. Never pull on wire, pull on connector.

DMate wire connectors properly. Center flat blade of insulated male connector in female connector.

DRoute wires carefully to avoid interference with other connections of pressure control. Do not pinch wires between cover and control box.

6309063

Image 6
Contents Repair 309063FSpecifications 309063Fire and Explosion Hazard Pressurized Aluminum Parts Hazard Component Identification and Function Pressure Relief Procedure Skin Injection HazardGeneral Repair Information Read Electric Shock Warning Burn Hazard WarningSprayer requires Sprayer cord includes a grounding wire with anGrounding and Electric Requirements Never use an outlet that is not grounded or an adapterTroubleshooting Motor WON’T OperateLOW or Fluctuating Output Placement Electric Shock Hazard Motor Brush ReplacementSpin Test Read General Repair InformationInstall pump 13 Displacement Pump Re- placement, 309063 On/Off Switch Replacement InstallationRemoval 232901, a Capacitor on Motor232900, A, B 233797, aWhite ON/OFF Black Switch Green Power Cord Motor Connector 100 Vac 240 Vac TP1 TP2Pressure Control Repair LED Sprayer Operation Indicates BlinksInstall motor control board 35 with five screws Pressure Adjust Potentiometer Installation Installation See Fig Removal See FigAssembly Drive Housing ReplacementDisassembly Remove pump 13 Displacement Pump Re- placement,Remove drive housing Drive Housing Replace- ment, Motor ReplacementRemove pump Displacement Pump Replace- ment, Install fluid manifold Pressure Control Replace- ment,Displacement Pump Replacement RemovalTechnical Data DimensionsGraco Information