Graco 309063F Pressure Control Repair, LED Sprayer Operation Indicates Blinks

Page 19

Pressure Control Repair

Motor Control Board Diagnostics

For these models and series only: 232900 A, B, C, D, E

232901 A, B, C, D

233797 A, B, C, D

233815 A, B, C, D

232903 A, B

232906 A, B

Note: Keep a new transducer on hand to use for test.

1.Remove four screws (18) and cover (39).

2.Turn ON/OFF switch ON.

3.Observe LED operation and reference following table:

4.

Relieve pressure and un-

plug sprayer before servic-

 

 

ing control board; page 6.

CAUTION

Do not allow sprayer to develop fluid pressure with- out transducer installed. Leave drain valve open if test transducer is used.

LED

SPRAYER OPERATION

INDICATES

BLINKS

 

 

 

 

 

Once

Sprayer runs

Normal operation

 

 

 

Once and

Sprayer shuts down and LED stays ON

Motor open circuit or bad

stays ON

 

control board

 

 

 

Two times

Sprayer shuts down and LED continues

Run away pressure. Pres-

repeatedly

to blink two times repeatedly

sure greater than 4500 psi

 

 

(310 bar, 31 MPa).

 

 

 

Three times

Sprayer shuts down and LED continues

Pressure transducer is

repeatedly

to blink three times repeatedly

faulty or missing

 

 

 

 

 

Four times

Sprayer shuts down and LED continues

Line voltage is too high

repeatedly

to blink four times repeatedly

 

 

 

 

Five times

Sprayer shuts down and LED continues

Too much current

repeatedly

to blink five times repeatedly

 

 

 

 

Six times

Sprayer shuts down and LED continues

Motor thermal switch

repeatedly

to blink six times repeatedly

open circuit

 

 

 

WHAT TO DO

Do nothing

Check motor brushes and armature. If OK, replace mo- tor control board.

Replace motor control board. See following Motor Control Board procedure.

Check transducer connection. Open drain valve. Substitute new transducer for transducer in sprayer. If sprayer runs, replace transducer.

Check for voltage supply problems

Check for locked rotor, shorted wiring or motor. Re- pair or replace failed parts.

Check for binding in pump or drive. Check for bad motor.

309063 19

Image 19
Contents 309063F Repair309063 SpecificationsFire and Explosion Hazard Pressurized Aluminum Parts Hazard Component Identification and Function Skin Injection Hazard Pressure Relief ProcedureRead Electric Shock Warning Burn Hazard Warning General Repair InformationNever use an outlet that is not grounded or an adapter Sprayer cord includes a grounding wire with anGrounding and Electric Requirements Sprayer requiresMotor WON’T Operate TroubleshootingLOW or Fluctuating Output Placement Read General Repair Information Motor Brush ReplacementSpin Test Electric Shock HazardInstall pump 13 Displacement Pump Re- placement, 309063 Installation On/Off Switch ReplacementRemoval 233797, a Capacitor on Motor232900, A, B 232901, aWhite ON/OFF Black Switch Green Power Cord Motor Connector 100 Vac TP1 TP2 240 VacLED Sprayer Operation Indicates Blinks Pressure Control RepairInstall motor control board 35 with five screws Pressure Adjust Potentiometer Installation Removal See Fig Installation See FigRemove pump 13 Displacement Pump Re- placement, Drive Housing ReplacementDisassembly AssemblyInstall fluid manifold Pressure Control Replace- ment, Motor ReplacementRemove pump Displacement Pump Replace- ment, Remove drive housing Drive Housing Replace- ment,Removal Displacement Pump ReplacementDimensions Technical DataGraco Information