Grounding and Electric Requirements

WARNING

Your system must be grounded. Read warnings, page 3.

The sprayer cord includes: a grounding wire with an

appropriate grounding contact.

 

ti7480a

Fig. 3

 

The sprayer requires:

110--120V units: 100--130 VAC, 50/60 Hz, 15A, 1 phase, circuit with a grounding receptacle.

240V Units: 210--255 VAC, 50/60 Hz, 7.5A, 1 phase, circuit with a grounding receptacle.

Never use an outlet that is not grounded or an adapter.

 

ti7482a

Fig. 5

 

Recommended extension cords for use with this sprayer:

D110--120V: 3--wire, 12 AWG (2.5 mm2) minimum, 300 ft. (90 m) maximum length.

D240V: 3--wire, 16 AWG (1.0 mm2) minimum, 300 ft. (90 m) maximum length.

Smaller gauge or longer extension cords may reduce sprayer performance.

Spray gun: ground through connection to a properly grounded fluid hose and pump.

Fluid supply container: follow local code.

Solvent and Oil--based fluids: follow local code. Use only conductive metal pails placed on a grounded surface such as concrete. Do not place the pail on a nonconductive surface such as paper or cardboard, which interrupts grounding continuity.

Grounding the metal pail: connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.

To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

ti7481a

 

 

Fig. 4

 

 

Do not use the sprayer if the electrical cord has a

 

 

damaged ground contact. Only use an extension cord

Fig. 6

ti7483a

with an undamaged ground contact.

 

8309063

Image 8
Contents Repair 309063FSpecifications 309063Fire and Explosion Hazard Pressurized Aluminum Parts Hazard Component Identification and Function Pressure Relief Procedure Skin Injection HazardGeneral Repair Information Read Electric Shock Warning Burn Hazard WarningSprayer cord includes a grounding wire with an Grounding and Electric RequirementsSprayer requires Never use an outlet that is not grounded or an adapterTroubleshooting Motor WON’T OperateLOW or Fluctuating Output Placement Motor Brush Replacement Spin TestElectric Shock Hazard Read General Repair InformationInstall pump 13 Displacement Pump Re- placement, 309063 Removal On/Off Switch ReplacementInstallation Capacitor on Motor 232900, A, B232901, a 233797, aWhite ON/OFF Black Switch Green Power Cord Motor Connector 100 Vac 240 Vac TP1 TP2Pressure Control Repair LED Sprayer Operation Indicates BlinksInstall motor control board 35 with five screws Pressure Adjust Potentiometer Installation Installation See Fig Removal See FigDrive Housing Replacement DisassemblyAssembly Remove pump 13 Displacement Pump Re- placement,Motor Replacement Remove pump Displacement Pump Replace- ment,Remove drive housing Drive Housing Replace- ment, Install fluid manifold Pressure Control Replace- ment,Displacement Pump Replacement RemovalTechnical Data DimensionsGraco Information