Graco 249377, 288217, 249369 important safety instructions Flush Spray Gun, Position Air Cap

Page 14

Setup

KEY

N Cylinder Air Inlet: accepts 1/4 in. (6.3 mm) O.D. tubing

P Atomization Air Inlet: 3/8 in, (9.5 mm) O.D. tubing

R Fan Air Inlet: 3/8 in. (9.5 mm) O.D, tubing

S Fluid Inlet: 1/4 npsm

T Fluid Outlet (circulating gun only): 1/4 npsm

Side Mounted Manifold Ports

N

T (or S)

S (or T)

FAN ATOM

CYL

TI8096a

RP

Bottom Mounted Manifold Ports

N

R

FAN

ATOM

P

 

 

 

CYL

 

T (or S)

 

 

S (or T)

 

 

 

TI8097a

FIG. 10: Manifold Ports

Flush Spray Gun

Before running any paint through the spray gun:

1.Flush the gun with a solvent that is compatible with the fluid to be sprayed, using the lowest possible fluid pressure and a grounded metal container.

2.Perform Pressure Relief Procedure; see page 17.

Position Air Cap

Air caps are factory-set with the alignment pin (A) set to a vertical spray pattern. To change the air cap to a hori- zontal spray pattern, use a needle nos pliers to unscrew the alignment pin (A) and relocate it to the horizontal spray pattern hole. When relocating the pin use low strength thread locker. Torque to 1.5-2.5 in-lb (0.2-0.3 N•m). Do not overtighten. Refer to FIG. 11.

TI8171a

Vertical Pattern

A

TI8170a

TI8172a Horizontal Pattern

FIG. 11: Position Air Cap

14

311051F

Image 14
Contents Automatic XT Spray Guns Contents Related ManualsCompliant Airspray ModelsOrifice Size In. mm Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Selection Charts Hvlp Spray Gun AssembliesCompliant Spray Gun Assemblies Airspray Gun AssembliesAir Caps Proper Needle/Nozzle SelectionGun Selection Air Flow Hvlp Gun Air Cap PressureConfigure Gun and Manifold InstallationVentilate Spray Booth Non-circulating System Install Air Fittings Ground SystemRetrofit Adapter Plate Mount GunReciprocating Arm Rod Mount Stationary SupportConnect Fluid Hose SetupConnect Air Line Flush Spray Gun Position Air CapAdjust Spray Pattern Compliant Hvlp and Compliant Gun LimitsAir Pressure Regulator Apply Fluid Pressure Relief ProcedureOperation IncorrectDaily Gun Care Perform Pressure Relief Procedure, General System MaintenanceClean and Flush Gun Problem Cause Solution TroubleshootingGeneral Troubleshooting Troubleshooting Spray Pattern Troubleshooting Replace Fluid Packings and Air Seals ServiceItems Needed for Service Alternate Fluid Control Shown Reassembly Parts Exploded View Part No Gun ShownPart No. Description Qty PartsAir Caps Orifice Size LargeSpray Gun Assemblies all models Needle TipsManifold with Bottom Fluid Ports Description Qty Manifold with Side Fluid PortsSide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Mounting Hole Layout Manifold Mounting Hole LayoutRear Port Manifold Retrofit Adapter Plate Gun with RetrofitTechnical Data Triggering SpeedGraco Standard Warranty Graco Information