Graco 288217, 249369, 249377 important safety instructions Accessories

Page 33

Accessories

Cleaning Brush 105749

For use in cleaning gun.

Lubricant 111265

One 4 oz. (113 gram) tube sanitary (non-silicone) lubri- cant for fluid seals and wear areas.

Fluid Hose Parts Breakdown

Part No. Description

239629 FITTING, assy, swivel

061345 TUBING, 1000 ft. (305 m) roll

Alternate Nozzle Sizes

Nozzle

Needle/

Needle

Needle

Nozzle

Orifice Size

Nozzle Kit

Assy.

Tip

 

in. (mm)

 

 

Qty. 1

 

 

 

 

 

 

0.059 (1.5)

N/A

288177

234778

234745

(6 grooves)

 

 

 

 

 

0.086 (2.2)

15F833

288179

234779

234747

(0 grooves)

 

 

 

 

 

0.110 (2.8)

15F834

288180

234780

234748

(0 grooves)

 

 

 

 

 

0.070 (1.8)

N/A

288182

N/A

234751

Hardened SST

 

 

 

 

 

 

 

 

 

Retrofit Adapter Plate 288197

The retrofit adapter plate enables the manifold to be attached to a variety of bolt patterns.

Accessories

HVLP Pressure Verification Kit

For use in checking air cap atomizing or pattern air pres- sure at various supply air pressures. Not to be used for actual spraying.

Install the kit air cap on the gun. Turn on the air to the gun, then trigger the gun and read the air pressure on the gauge.

To be “HVLP compliant”, the atomizing air pressure must not exceed 10 psi (70 kPa, 0.7 bar).

Part No.

Orifice in. (mm)

 

 

 

234736

0.030

- 0.070 (0.8 - 1.8)

 

 

 

234737

0.086

(2.2)

 

 

 

234738

0.110

(2.8)

 

 

 

TI7637a

FIG. 27: HVLP Pressure Verification Kit

Fluid Control Knob Repair Kit 288138

Includes spring, ball, and retaining clip.

311051F

33

Image 33
Contents Automatic XT Spray Guns Related Manuals ContentsModels Orifice Size In. mmCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Hvlp Spray Gun Assemblies Selection ChartsAirspray Gun Assemblies Compliant Spray Gun AssembliesProper Needle/Nozzle Selection Gun SelectionAir Caps Hvlp Gun Air Cap Pressure Air FlowVentilate Spray Booth InstallationConfigure Gun and Manifold Non-circulating SystemGround System Install Air FittingsReciprocating Arm Rod Mount Mount GunRetrofit Adapter Plate Stationary SupportSetup Connect Air LineConnect Fluid Hose Position Air Cap Flush Spray GunCompliant Hvlp and Compliant Gun Limits Adjust Spray PatternAir Pressure Regulator Operation Pressure Relief ProcedureApply Fluid IncorrectDaily Gun Care General System Maintenance Clean and Flush GunPerform Pressure Relief Procedure, Troubleshooting General TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Service Items Needed for ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Exploded View Part No Gun Shown PartsAir Caps PartsPart No. Description Qty Orifice Size LargeNeedle Tips Spray Gun Assemblies all modelsManifold with Bottom Fluid Ports Manifold with Side Fluid Ports Description QtySide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Manifold Mounting Hole Layout Mounting Hole LayoutRetrofit Adapter Plate Gun with Retrofit Rear Port ManifoldTriggering Speed Technical DataGraco Information Graco Standard Warranty