Graco 249369 General System Maintenance, Clean and Flush Gun, Perform Pressure Relief Procedure

Page 19

General System Maintenance

Perform Pressure Relief Procedure, page 17.

Clean the fluid and air line filters daily.

Check for any fluid leakage from the gun and fluid hoses. Tighten fittings or replace equipment as needed.

Flush the gun before changing colors and whenever you are done operating the gun.

Clean and Flush Gun

1.Perform Pressure Relief Procedure, page 17.

2.Shut off the gun fan and atomizing air.

3.Supply a compatible solvent to the gun fluid inlet.

4.Point the gun down into a grounded metal container, and flush the gun with solvent until all traces of paint are removed from the gun passages.

5.Perform Pressure Relief Procedure, page 17.

6.Disconnect the solvent supply.

7.Remove the air cap retaining ring and air cap.

CAUTION

Trigger the gun or remove the piston cap whenever you tighten or remove the nozzle. This keeps the nee- dle seat away from the nozzle seating surface and prevents the seat from being damaged.

8.Clean the air cap retaining ring, air cap, and fluid nozzle with solvent.

9.Dip the end of a soft-bristle brush into a compatible solvent. Do not continuously soak the brush's bris- tles with solvent and do not use a wire brush.

Daily Gun Care

10.With the gun pointed down, clean the front of the gun, using the soft-bristle brush and solvent.

11.Scrub the air cap retaining ring, air cap, and fluid nozzle with the soft-bristle brush (see FIG. 17). To clean out air cap holes, use a soft implement, such as a toothpick, to avoid damaging critical surfaces. Clean the air cap and fluid nozzle daily, minimum. Some applications require more frequent cleaning.

TI8176a

FIG. 17:

12.Install the air cap retaining ring and air cap.

13.Dampen a soft cloth with solvent and wring-out the excess. Point the gun down and wipe off the outside of the gun.

TI4845a

FIG. 16:

311051F

19

Image 19
Contents Automatic XT Spray Guns Related Manuals ContentsOrifice Size In. mm ModelsCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Hvlp Spray Gun Assemblies Selection ChartsAirspray Gun Assemblies Compliant Spray Gun AssembliesGun Selection Proper Needle/Nozzle SelectionAir Caps Hvlp Gun Air Cap Pressure Air FlowNon-circulating System InstallationVentilate Spray Booth Configure Gun and ManifoldGround System Install Air FittingsStationary Support Mount GunReciprocating Arm Rod Mount Retrofit Adapter PlateConnect Air Line SetupConnect Fluid Hose Position Air Cap Flush Spray GunCompliant Hvlp and Compliant Gun Limits Adjust Spray PatternAir Pressure Regulator Incorrect Pressure Relief ProcedureOperation Apply FluidDaily Gun Care Clean and Flush Gun General System MaintenancePerform Pressure Relief Procedure, General Troubleshooting TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Items Needed for Service ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Exploded View Part No Gun Shown PartsOrifice Size Large PartsAir Caps Part No. Description QtyNeedle Tips Spray Gun Assemblies all modelsManifold with Bottom Fluid Ports Manifold with Side Fluid Ports Description QtySide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Manifold Mounting Hole Layout Mounting Hole LayoutRetrofit Adapter Plate Gun with Retrofit Rear Port ManifoldTriggering Speed Technical DataGraco Information Graco Standard Warranty