Reassembly

1.Non-circulating guns only: Lubricate the backup ring (20†) and o-ring (21†) and install them on the fluid outlet port plug (19). Install the plug in the fluid out- let port of the fluid housing (2). See FIG. 22.

2.All guns: Reinstall the gasket (22) in the fluid hous- ing (2).

3.Install the o-rings (8*, 9*) on the piston (3). Install the two o-rings (10*, 11*) on each of the piston stems (T). Lubricate all the o-rings, the piston, and the piston stems.

4.Remove the protective paper from the sticky side of the gasket (12*) and adhere the gasket to the bot- tom of the piston housing (1), making sure the three holes in the gasket are properly aligned with the matching holes in the housing.

5.Lubricate the new fluid packing (17†) and insert it into the packing nut (16). Insert the packing nut into the fluid housing (2) and torque to 95-105 in-lb (10.7-11.8 N•m).

6.Align the gasket (15*) as shown in the exploded view in FIG. 22. Place the gasket on the piston hous- ing (1), then install the fluid housing (2) onto the pis- ton housing. Torque the two screws (14) to 30 in-lb (3.4 N•m).

a.Insert the piston (3) into the piston housing (1).

b.Ensure nozzle sealing o-ring (36) is installed in fluid housing (2).

7.To avoid galling of the fluid nozzle seat in the fluid housing, apply a thin film of lubricant to the threads. Install the nozzle into the fluid housing. Torque the nozzle securely to 60 in-lb (6.8 N•m).

If you are replacing the needle tip (5a), apply semi-permanent anaerobic sealant to two threads at the end of the needle shaft. Assemble the needle tip to the shaft and hand tighten. Allow adequate time for the sealant to cure before installing the needle assembly into the gun.

8.Lubricate and install the needle (5) into the back of the gun assembly. Push it straight in through the pis- ton.

9.Install the needle stop (29) on the needle. Coat the setscrew (30) with semi-permanent anaerobic seal-

Service

ant and install the screw into the needle stop. Torque to 4-5 in-lb (0.45-0.56 N•m). Pull on the nee- dle to make sure it seats fully.

10.Install the springs (6, 7).

11.Lubricate the threads of the piston housing (1). Screw the cap (4) onto the housing until it bottoms out.

12.Install the air cap (24) and air cap retainer (25).

13.Reinstall the gun on the manifold using the four screws (13). Start the threads of all four screws. Tighten the front two screws first, and then tighten the back two. Torque all four screws evenly to 65 in-lb (7.3 N•m).

311051F

25

Image 25
Contents Automatic XT Spray Guns Related Manuals ContentsOrifice Size In. mm ModelsCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Hvlp Spray Gun Assemblies Selection ChartsAirspray Gun Assemblies Compliant Spray Gun AssembliesGun Selection Proper Needle/Nozzle SelectionAir Caps Hvlp Gun Air Cap Pressure Air FlowVentilate Spray Booth InstallationConfigure Gun and Manifold Non-circulating SystemGround System Install Air FittingsReciprocating Arm Rod Mount Mount GunRetrofit Adapter Plate Stationary SupportConnect Air Line SetupConnect Fluid Hose Position Air Cap Flush Spray GunCompliant Hvlp and Compliant Gun Limits Adjust Spray PatternAir Pressure Regulator Operation Pressure Relief ProcedureApply Fluid IncorrectDaily Gun Care Clean and Flush Gun General System MaintenancePerform Pressure Relief Procedure, General Troubleshooting TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Items Needed for Service ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Exploded View Part No Gun Shown PartsAir Caps PartsPart No. Description Qty Orifice Size LargeNeedle Tips Spray Gun Assemblies all modelsManifold with Bottom Fluid Ports Manifold with Side Fluid Ports Description QtySide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Manifold Mounting Hole Layout Mounting Hole LayoutRetrofit Adapter Plate Gun with Retrofit Rear Port ManifoldTriggering Speed Technical DataGraco Information Graco Standard Warranty